Elcometer 130 Salt Contamination Meter
- Protective Coatings


The Elcometer 130 Salt Contamination Meter quickly and accurately measures the level of soluble salts on surfaces over 4 times faster than Bresle equivalent test methods.
- Summary
-
Summary
-
Accurate
- Conductivity measurement to ±1%
- Can be used in accordance with National and International Standards
- Automatic temperature compensation ensures repeatable, accurate results
- Calibration verification tiles
- Trend and batch readings graph format for an instant on screen analysis
Efficient
- Instant readings allow multiple tests to be completed efficiently
- Alphanumeric batch identification
- Compatible with ElcoMaster® software and ElcoMaster® Mobile App
- Calibration offset allows the use of non-pure water up to 2μg/cm²
Powerful
- Measuring range up to 50μg/cm² (3000ppm)
- USB and Bluetooth® data output to iPhone1 or Android™ devices
- Stores up to 100,000 readings in 1,000 batches
- Soluble salt and conductivity meter in one gauge
- Fast reading rate allows multiple tests to be completed efficiently
- Automatic temperature compensation ensures accurate results
- Pressure plate ensures a constant and uniform pressure to the paper
- Non-oxidising gold plated contacts ensures lifetime accuracy
- Fully portable hand-held, an ergonomic design ideal for use in the field
- Dust and water resistant rugged design equivalent to IP64
- Stores up to 100,000 readings in 1,000 alpha numeric batches
- USB and Bluetooth® data output to ElcoMaster® software
-
- Key Features
-
Key Features
Elcometer 130 Salt Contamination Meter
User Friendly
- Large buttons ideal for gloved hands
- Easy to use menus in multiple languages
- High reading limit indicator
- Factory calibrated for immediate use
Tough
- Heavy duty, impact resistant, dust and waterproof design equivalent to IP64
- Wipe clean sealed unit ideal for harsh environments
- Scratch and solvent resistant display
Reliable
- Repeatable and reproducible measurements
- 2 year gauge warranty
- Supplied with fully traceable Test Certificates
- Batch & individual readings are stored with date and time stamp
How to use a Salt Contamination Meter
Fill the syringe with 1.6ml of pure distilled water.
Note: Non-pure water (up to 2µg/cm²) can be automatically offset with the gauge.
Using tweezers, remove a filter paper from the pack and place it on the cleaned, non labelled side of the magnetic disc supplied.
Disperse the water from the syringe, evenly across the whole of the filter paper and remove any bubbles from under the paper.
Place the magnetic disc, with the wetted paper face down onto the area under test, pressing firmly into any contours or irregularities and start the 2 minute timer on the gauge.
Whilst waiting for the sample time to elapse, additional tests can be prepared.
After 2 minutes, carefully remove the filter paper and magnetic disc from the test surface and place them onto the measurement electrodes.
Close the lid, ensuring that the magnetic catch is fully engaged.
The reading will automatically be displayed and stored into memory together with date and time.
Place the filter paper in a resealable bag (supplied), if required for further analysis.
1 Compatible with iPod, iPhone and iPad
Elcometer 130 Model T: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation).
“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.
-
- Product Features
-
Product FeaturesElcometer 130 Salt Contamination Meter
Product Features Standard Optional Model Model S Model T Repeatable & reproducible measurements Easy to use menu structure; in 30+ languages Tough, impact, waterproof & dust resistant; equivalent to IP64 Bright colour screen; with permanent backlight Scratch and solvent resistant display; 2.4" (6cm) TFT 2 year gauge warranty1 USB power supply; via PC Calibration certificate Calibration Verification Mode (with optional certified calibration tile) Ambient light sensor; with adjustable auto brightness Emergency Light Mode Magnetic & tripod mounting points Gauge software updates; via ElcoMaster® software Data output USB; to computer Bluetooth®; to computer, Android™ & iOS2 devices ElcoMaster® software & USB cable On Screen Statistics Number of readings (n); Mean (average) (x) ; Standard deviation (σ); Highest reading (Hi); Lowest reading (Lo); Coefficient of variation (CV%); Number of readings above high limit Gauge memory Number of readings 100,000Number of batches 1,000Measurement units & range 0-25µg/cm²0-50μg/cm², 0-6000μS/cm, 0-3000ppm, 0-6mS/cm, 0-500mg/m², 0-0.3% SalinityMeasurement Mode Surface Cleanliness Conductivity Calibration Offset Mode Automatic temperature compensation Individual reading and profile map stored with time and date Plastic transit case Alpha-numeric batch names; user definable on the gauge Fixed Batch Size Mode; with batch linking Delete last reading Limits; user definable audible & visual pass/fail warnings Review, copy, clear & delete batches & calibration settings Trend graph; last 20 readings Batch review graph Analogue bar graph 1 The Elcometer 130 is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase.
2 Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.
-
- Technical Information
-
Technical SpecificationElcometer 130 Salt Contamination Meter
Model S Model T Description Certificate E130-S E130-T Elcometer 130 Salt Contamination Meter E130-SC E130-TC Elcometer 130 Certified Salt Contamination Meter Model T Model T Measurement Range 0-25μg/cm² 0-50μg/cm²; 0-500mg/m²;
0-6000μS/cm; 0-6mS/cm; 0-3000ppm; 0-0.3% SalinityResolution 0.1μg/cm² 0.1μg/cm², 1mg/m²
1μS/cm, 0.001mS/cm
1ppm, 0.0001% SalinityMeasurement Accuracy ±1% of reading ±0.1μg/cm² Operating Range 5°C - 40°C (41°F - 104°F) Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used), or power via USB Number of Tests Approximately 4,000 measurements before battery replacement Sample Time Sample Time Sampling Size 110mm (4.3”) diameter circle Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9") Weight 780g (1.72lb) Packing List Elcometer 130 Salt Contamination Meter, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable (T), ElcoMaster® software (T) Model T Model T Certificate E130-S E130-T Description Elcometer 130 Salt Contamination Meter Model T Model T Certificate E130-SC E130-TC Description Elcometer 130 Certified Salt Contamination Meter Measurement Range Model S
0-25μg/cm²Model T 0-50μg/cm²; 0-500mg/m²;
0-6000μS/cm; 0-6mS/cm; 0-3000ppm; 0-0.3% SalinityResolution Model S
0.1μg/cm²Model T 0.1μg/cm²; 1mg/m²
1μS/cm; 0.001mS/cm
1ppm; 0.0001% SalinityMeasurement Accuracy ±1% of reading ±0.1μg/cm² Operating Range 5°C - 40°C (41°F - 104°F) Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used), or power via USB Number of Tests Approximately 4,000 measurements before battery replacement Sample Time Sample Time Sampling Size 110mm (4.3”) diameter circle Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9") Weight 780g (1.72lb) Packing List Elcometer 130 Salt Contamination Meter, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable (T), ElcoMaster® software (T) ● Calibration certificate supplied as standard
-
- Standards
-
StandardsElcometer 130 Salt Contamination Meter
SSPC Guide 15
-
- Downloads
-
Downloads
- Part Numbers
-
Part NumbersElcometer 130 Salt Contamination MeterNo data found!!
-
Elcometer 130 Model S Salt Contamination Meter
- Model: Model S
- Part Number : E130-S
-
Elcometer 130 Model S Certified Salt Contamination Meter
- Model: Model S
- Part Number : E130-SC
-
Elcometer 130 Model T Salt Contamination Meter
- Model: Model T
- Part Number : E130-T
-
Elcometer 130 Model T Certified Salt Contamination Meter
- Model: Model T
- Part Number : E130-TC
- Accessories
-
AccessoriesElcometer 130 Salt Contamination Meter
- Part Number: T99921325
- Part Number: T99922341
- Part Number: T13025964
- Part Number: T13024091
- Part Number: T13024093
- Part Number: T99911344
- Part Number: T13027596
- Part Number: T13024094
- Part Number: T13024092
- Part Number: T13024098
- Part Number: T13024087
- Part Number: T13023980
Welcome to Elcometer.tv
Your ultimate training channel
- Home
- Coatings Inspection
- Coatings Inspection Division
- Surface Cleanliness
- Elcometer 130 Salt Contamination Meter
Elcometer 130 Salt Contamination Meter
- Protective Coatings
The Elcometer 130 Salt Contamination Meter quickly and accurately measures the level of soluble salts on surfaces over 4 times faster than Bresle equivalent test methods.
Accurate
- Conductivity measurement to ±1%
- Can be used in accordance with National and International Standards
- Automatic temperature compensation ensures repeatable, accurate results
- Calibration verification tiles
- Trend and batch readings graph format for an instant on screen analysis
Efficient
- Instant readings allow multiple tests to be completed efficiently
- Alphanumeric batch identification
- Compatible with ElcoMaster® software and ElcoMaster® Mobile App
- Calibration offset allows the use of non-pure water up to 2μg/cm²
Powerful
- Measuring range up to 50μg/cm² (3000ppm)
- USB and Bluetooth® data output to iPhone1 or Android™ devices
- Stores up to 100,000 readings in 1,000 batches
- Soluble salt and conductivity meter in one gauge
Summary
Elcometer 130 Salt Contamination Meter
- Fast reading rate allows multiple tests to be completed efficiently
- Automatic temperature compensation ensures accurate results
- Pressure plate ensures a constant and uniform pressure to the paper
- Non-oxidising gold plated contacts ensures lifetime accuracy
- Fully portable hand-held, an ergonomic design ideal for use in the field
- Dust and water resistant rugged design equivalent to IP64
- Stores up to 100,000 readings in 1,000 alpha numeric batches
- USB and Bluetooth® data output to ElcoMaster® software
Key Features
Elcometer 130 Salt Contamination Meter
User Friendly
- Large buttons ideal for gloved hands
- Easy to use menus in multiple languages
- High reading limit indicator
- Factory calibrated for immediate use
Tough
- Heavy duty, impact resistant, dust and waterproof design equivalent to IP64
- Wipe clean sealed unit ideal for harsh environments
- Scratch and solvent resistant display
Reliable
- Repeatable and reproducible measurements
- 2 year gauge warranty
- Supplied with fully traceable Test Certificates
- Batch & individual readings are stored with date and time stamp
How to use a Salt Contamination Meter
Fill the syringe with 1.6ml of pure distilled water.
Note: Non-pure water (up to 2µg/cm²) can be automatically offset with the gauge.
Using tweezers, remove a filter paper from the pack and place it on the cleaned, non labelled side of the magnetic disc supplied.
Disperse the water from the syringe, evenly across the whole of the filter paper and remove any bubbles from under the paper.
Place the magnetic disc, with the wetted paper face down onto the area under test, pressing firmly into any contours or irregularities and start the 2 minute timer on the gauge.
Whilst waiting for the sample time to elapse, additional tests can be prepared.
After 2 minutes, carefully remove the filter paper and magnetic disc from the test surface and place them onto the measurement electrodes.
Close the lid, ensuring that the magnetic catch is fully engaged.
The reading will automatically be displayed and stored into memory together with date and time.
Place the filter paper in a resealable bag (supplied), if required for further analysis.
1 Compatible with iPod, iPhone and iPad
Elcometer 130 Model T: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation).
“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.
Product FeaturesElcometer 130 Salt Contamination MeterProduct Features Standard Optional Model Model S Model T Repeatable & reproducible measurements Easy to use menu structure; in 30+ languages Tough, impact, waterproof & dust resistant; equivalent to IP64 Bright colour screen; with permanent backlight Scratch and solvent resistant display; 2.4" (6cm) TFT 2 year gauge warranty1 USB power supply; via PC Calibration certificate Calibration Verification Mode (with optional certified calibration tile) Ambient light sensor; with adjustable auto brightness Emergency Light Mode Magnetic & tripod mounting points Gauge software updates; via ElcoMaster® software Data output USB; to computer Bluetooth®; to computer, Android™ & iOS2 devices ElcoMaster® software & USB cable On Screen Statistics Number of readings (n); Mean (average) (x) ; Standard deviation (σ); Highest reading (Hi); Lowest reading (Lo); Coefficient of variation (CV%); Number of readings above high limit Gauge memory Number of readings 100,000Number of batches 1,000Measurement units & range 0-25µg/cm²0-50μg/cm², 0-6000μS/cm, 0-3000ppm, 0-6mS/cm, 0-500mg/m², 0-0.3% SalinityMeasurement Mode Surface Cleanliness Conductivity Calibration Offset Mode Automatic temperature compensation Individual reading and profile map stored with time and date Plastic transit case Alpha-numeric batch names; user definable on the gauge Fixed Batch Size Mode; with batch linking Delete last reading Limits; user definable audible & visual pass/fail warnings Review, copy, clear & delete batches & calibration settings Trend graph; last 20 readings Batch review graph Analogue bar graph 1 The Elcometer 130 is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase.
2 Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.
Technical SpecificationElcometer 130 Salt Contamination MeterModel S Model T Description Certificate E130-S E130-T Elcometer 130 Salt Contamination Meter E130-SC E130-TC Elcometer 130 Certified Salt Contamination Meter Model T Model T Measurement Range 0-25μg/cm² 0-50μg/cm²; 0-500mg/m²;
0-6000μS/cm; 0-6mS/cm; 0-3000ppm; 0-0.3% SalinityResolution 0.1μg/cm² 0.1μg/cm², 1mg/m²
1μS/cm, 0.001mS/cm
1ppm, 0.0001% SalinityMeasurement Accuracy ±1% of reading ±0.1μg/cm² Operating Range 5°C - 40°C (41°F - 104°F) Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used), or power via USB Number of Tests Approximately 4,000 measurements before battery replacement Sample Time Sample Time Sampling Size 110mm (4.3”) diameter circle Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9") Weight 780g (1.72lb) Packing List Elcometer 130 Salt Contamination Meter, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable (T), ElcoMaster® software (T) Model T Model T Certificate E130-S E130-T Description Elcometer 130 Salt Contamination Meter Model T Model T Certificate E130-SC E130-TC Description Elcometer 130 Certified Salt Contamination Meter Measurement Range Model S
0-25μg/cm²Model T 0-50μg/cm²; 0-500mg/m²;
0-6000μS/cm; 0-6mS/cm; 0-3000ppm; 0-0.3% SalinityResolution Model S
0.1μg/cm²Model T 0.1μg/cm²; 1mg/m²
1μS/cm; 0.001mS/cm
1ppm; 0.0001% SalinityMeasurement Accuracy ±1% of reading ±0.1μg/cm² Operating Range 5°C - 40°C (41°F - 104°F) Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used), or power via USB Number of Tests Approximately 4,000 measurements before battery replacement Sample Time Sample Time Sampling Size 110mm (4.3”) diameter circle Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9") Weight 780g (1.72lb) Packing List Elcometer 130 Salt Contamination Meter, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable (T), ElcoMaster® software (T) ● Calibration certificate supplied as standardPart NumbersElcometer 130 Salt Contamination MeterNo data found!!-
Elcometer 130 Model S Salt Contamination Meter
- Model: Model S
- Part Number : E130-S
-
Elcometer 130 Model S Certified Salt Contamination Meter
- Model: Model S
- Part Number : E130-SC
-
Elcometer 130 Model T Salt Contamination Meter
- Model: Model T
- Part Number : E130-T
-
Elcometer 130 Model T Certified Salt Contamination Meter
- Model: Model T
- Part Number : E130-TC
Welcome to Elcometer.tv
Your ultimate training channelAccessoriesElcometer 130 Salt Contamination Meter- Part Number: T99921325
- Part Number: T99922341
- Part Number: T13025964
- Part Number: T13024091
- Part Number: T13024093
- Part Number: T99911344
- Part Number: T13027596
- Part Number: T13024094
- Part Number: T13024092
- Part Number: T13024098
- Part Number: T13024087
- Part Number: T13023980
- Part Numbers
-