

Elcometer 480 Single, Dual & Triple Angle Glossmeters
- Industrial Finishing


The Elcometer 480 range of handheld glossmeters combine accuracy, repeatability and reproducibility with functionality allowing you to measure Gloss, % Reflectance & Haze with ease.
- Summary
-
Summary
-
Accurate
- Date and time stamped readings
- Differential mode with pass/fail
- Repeatable & reproducible readings
- 40 user definable limit standards
Efficient
- Small, robust & ergonomic
- Multiple angles; 20°, 60°, 85°
- Display readings, statistics, graphs & batch review
- Standard, auto repeat and scan modes
- Automatic gauge & tile diagnostics
- Auto calibration tile recognition via RFID*
*Radio Frequency Identification; European Patent Number: 2906904
Powerful
- USB & Bluetooth® data output
- PC, iPhone or Android™ compatible
- 40,000 reading memory in up to 2,500 batches
- 3 - 10 readings per second
Using state-of-the-art design and manufacturing techniques, the Elcometer 480 Glossmeters quickly and accurately measure and record gloss measurements on a wide range of materials, including paint, plastic, ceramic or metal.
The Elcometer 480 gloss meter rapid LED technology accurately measures up to 3 gloss angles at the same time at a rate of 10 readings per second. Gloss measurements can be instantly transferred from the glossmeter to PC, iPhone, Android™ or other mobile devices via USB or Bluetooth®.
-
- Key Features
-
Key Features
Elcometer 480 Single, Dual & Triple Angle Glossmeters
The Model Range
The Elcometer 480 Glossmeter is available as either a simple entry level 60° glossmeter or state of the art Single, Dual or Triple angle gloss meter variants.
The Elcometer 480 Glossmeter is available with (Model T) or without (Model B) memory.
The Elcometer 480 Model B gloss meter is a 60° unit, Model T gloss meters are available as single, dual or triple angle variants with %Reflectance and Haze.
Accuracy & Repeatability
Advanced electronics and a superior optical design combines highly accurate, repeatable and reproducible measurements with industry leading inter-instrument agreement - across the Elcometer 480 Glossmeter’s entire 0-2,000GU range.
Range: 0-10GU 10-100GU 100-2000GU
Repeatability: ±0.1GU ±0.2GU ±0.2%
Reproducibility: ±0.2GU ±0.5GU ±0.5%
Calibration and Diagnostics
Every Elcometer 480 Gloss Meter Gloss Tile is fitted with an RFID (radio frequency identification) tag which allows automatic identification of the tile's serial number and calibration data when the tile is attached to the base of the glossmeter.
Additional calibration tiles are available from the range of Elcometer 480 glossmeter accessories. View accessories to find out more.
Measurement Speed
The Elcometer 480 Glossmeter's rapid LED technology accurately and repeatably measures up to 3 angles at the same time.
Standard Mode: 1+ reading per second, (70+ readings per minute)>< 0.3 seconds per angle
Auto Repeat Mode: 3 readings per second, (180 readings per minute); ~ 0.1 seconds per angle
Scan Mode: 10 readings per second, (600 readings per minute); ~ 0.03 seconds per angle
Display Modes
Fully customisable, scratch and solvent resistant colour LCD allows the user to display:
- Gloss, % Reflectance or Haze measurements
- Statistics
- Readings and Differential with pass/fail
- Trend Graph
- Analogue Scan Bar
Triple angle readings
Gloss, Haze & %Reflectance
Readings & user selectable statistics
Readings & differential with pass/ fail
Run chart & statistics
Readings & differential with analogue scan bar
Standard, Auto Repeat & Scan Modes
No two inspections are the same. It is for this reason that the Elcometer 480 Glossmeter is equipped with three gloss measurement modes:
Standard Mode: Press the measure button to take an individual spot gloss measurement.
Auto Repeat Mode: When the glossmeter is slid over the surface a measurement of all three angles is automatically taken at a user definable rate between 10 - 180 readings per minute. When enabled all the individual readings are stored into memory.
Scan Mode: As the glossmeter slides over the entire surface area, the gauge measures all three gloss angles at a continuous rate of 10 readings per second. When stopped, the glossmeter displays and stores the average, highest and lowest gloss values - ideal for checking a sample's overall uniformity.Standard Mode
Auto Repeat Mode
Scan Mode
Memory and Batching
Store 40,000 date and timed stamped readings in up to 2,500 user definable alpha-numeric batches.
Readings can be transferred to PC, iPhone, Android™ or other mobile devices via USB or Bluetooth® for instant reporting using ElcoMaster® software.
Limit Standards and Differential Mode with Pass/Fail
When visual appearance is critical Master Standards are created. These are generated and approved by the customer and then used by manufacturers as part of their quality control inspection regime. As these Master Standards have been visually approved they often do not have numerical gloss values assigned.
In order to avoid subjectivity between inspectors, the Elcometer 480 Glossmeter can automatically generate and store the nominal (target), highest & lowest acceptable gloss values (Limits) from the Master Standard.
Up to 40 Limits for each customer’s Master Standards can be stored within, and recalled from, the gauge’s ‘Limit Standards’ memory.
When Limit Standards are used in combination with the gauge’s Differential Mode, the Elcometer 480 Gloss Meter displays the measurement value together with the difference from the nominal (target) value.
Readings outside the Limit Standards are displayed in red, providing quick Pass/Fail analysis.
Due to the Elcometer 480 Glossmeters industry leading inter-instrument agreement, once a Master Standard Limit has been created, the gauge can transfer these values to other Elcometer 480 glossmeters, via the ElcoMaster® Software’s Library of Limit Standards, at any time.
Information from multiple glossmeters can be combined into a single inspection report within ElcoMaster® Software, ideal for multiple production and assembly lines.
Create instant reports with ElcoMaster®
What you do with the collected data is just as important as taking the readings themselves.
Data transferred to ElcoMaster® includes;
- 20° 60° & 85° Gloss Units (GU)
- Haze Unit (HU)
- % Reflectance (%)
- Date & time for each reading
- Limit Standard values
- Batch information & statistics
- Calibration information including date/time, serial number & tile values
Elcometer 480 Model T: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPhone 4, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (4th and 5th generation).“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.
-
- Product Features
-
Product FeaturesElcometer 480 Single, Dual & Triple Angle Glossmeters
Model B Model T Measurement geometries 60° 60°, 20/60° or 20/60/85°* Measurement Units GU GU, HU1 & % Fast, accurate reading rate Repeatable & reproducible measurements Easy to use menu structure; in 30+ languages Tough, impact, waterproof & dust resistant Scratch & solvent resistant display; 2.4” (6cm) TFT Rotating display: auto, 0°, 180° Ambient light sensor; with adjustable auto brightness Data Output USB live readings USB batch download Bluetooth®: to PC, iOS or Android™ mobile devices USB & battery powered Calibration certificate Manual gauge calibration Auto gauge calibration; via RFID tagging of integrated calibration tile2 On screen statistics Number of readings, Mean (average), Standard deviation, Highest reading, Lowest reading, Range Coefficient of variation, Nominal value, High Limit value, Low Limit value Number above high limit, Number below low limit Measurement modes Standard Mode Auto Repeat Mode; programmable 10-180 readings per minute Scan Mode; 10 readings per second Differential Mode with Pass/ Fail mode; Limit Standards; up to 40 programmable standards Gauge & batch specific standard limits Gauge memory 40,000 readings in up to 2,500 batches Alpha-numeric batch names Fixed Batch Size Mode Date & time stamp Gauge auto diagnostics Display modes; user selectable Readings; gloss, % reflectance, haze1 Selected statistics Trend graph; last 20 readings Scan bar display Readings & differential (with pass/fail) Delete last reading 2 year extended warranty3 * Dependant on model
1 Haze on Dual and Triple models only
2 Radio Frequency Identification; European Patent Number: 2906904
3 The Elcometer 480 is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase.
-
- Technical Information
-
Technical SpecificationElcometer 480 Single, Dual & Triple Angle Glossmeters
Part Number Description Certificate J480B-6 Elcometer 480 Model B 60° Glossmeter J480T-6 Elcometer 480 Model T 60° Glossmeter J480T-26 Elcometer 480 Model T 20/60° Glossmeter J480T-268 Elcometer 480 Model T 20/60/85° Glossmeter Display information 2.4’’ (6cm) QVGA colour TFT display, 320 x 240 pixels Power Supply USB (via PC) or 2x AA batteries (~50,000 readings) 20° 60° 85° Measurement Dimensions 20°: 10 x 10mm 60°: 8 x 16mm 85°: 4 x 55mm Measurement Range 20°: 0 - 2000GU 60°: 0 - 1000GU 85°:0 - 160GU Repeatability 20°: ± 0.1GU (0 - 10GU) 60°: ±0.2GU (10 - 100GU) 85°: ±0.2%: 100 - 2000GU Reproducibility 20°: ± 0.2GU (0 - 10GU) 60°: ±0.5GU (10 - 100GU) 85°: ±0.5% 100 - 2000GU Resolution Gloss 0.01% (0 - 10%), 0.1% (10 - 100%) % Reflectance 0.1 HU (0 - 100HU), 1 HU (>100HU) Haze -10°C to 50°C (14 to 122°F) Operating Temperature -10°C to 50°C (14 to 122°F) Relative Humidity 0 - 85%RH Dimensions 68 x 155 x 50mm (2.68 x 6.10 x 1.97ˮ) Weight 534g (1lb 3oz) [including batteries] Packing List Elcometer 480 Glossmeter, integrated calibration tile, calibration certificates for gauge & calibration tile, 2x AA batteries, wrist strap, operating instructions, plastic carry case, ElcoMaster® Software (Model T) and USB cable (Model T) Part Number Description Certificate J480B-6 Elcometer 480 Model B 60° Glossmeter J480T-6 Elcometer 480 Model T 60° Glossmeter J480T-26 Elcometer 480 Model T 20/60° Glossmeter J480T-268 Elcometer 480 Model T 20/60/85° Glossmeter Display information 2.4’’ (6cm) QVGA colour TFT display, 320 x 240 pixels Power Supply USB (via PC) or 2x AA batteries (~50,000 readings) Measurement Dimensions 20°: 10 x 10mm, 60°: 8 x 16mm, 85°: 4 x 55mm Measurement Range 20°: 0 - 2000GU, 60°: 0 - 1000GU, 85°:0 - 160GU Repeatability 20°: ± 0.1GU (0 - 10GU), 60°: ±0.2GU (10 - 100GU), 85°: ±0.2%: 100 - 2000GU Reproducibility 20°: ± 0.2GU (0 - 10GU), 60°: ±0.5GU (10 - 100GU), 85°: ±0.5% 100 - 2000GU Gloss 0.1 GU (0 - 100GU), 1 GU (>100GU) % Reflectance 0.01% (0 - 10%), 0.1% (10 - 100%) Haze 0.1 HU (0 - 100HU), 1 HU (>100HU) Operating Temperature -10°C to 50°C (14 to 122°F) Relative Humidity 0 - 85%RH Dimensions 68 x 155 x 50mm (2.68 x 6.10 x 1.97ˮ) Weight 534g (1lb 3oz) [including batteries] Packing List Elcometer 480 Glossmeter, integrated calibration tile, calibration certificates for gauge & calibration tile, 2x AA batteries, wrist strap, operating instructions, plastic carry case, ElcoMaster® Software (Model T) and USB cable (Model T) ● Certificate supplied as standard.
-
- Standards
-
StandardsElcometer 480 Single, Dual & Triple Angle Glossmeters
AS/NZS 1580.602.2, ASTM C584, ASTM D523, ASTM D1455, ASTM D2457, ASTM D4039, ASTM E430, ASTM E2387, BS 3900 D5, DIN 67530, ECCA T2, EN 12373-11, EN 13523-2, ISO 7668, ISO 2813, ISO 13803, JIS K 5600-4-7, JIS Z 8741, TAPPI T 653 (20°)
Standards in grey have been superseded but are still recognised in some industries.
-
- Downloads
-
Downloads
-
Elcometer 480 Single, Dual & Triple Angle Glossmeter Multi-Lingual Instruction Manual
-
Elcometer 480 Single, Dual & Triple Angle Glossmeter Datasheet
-
Elcometer 480 Model B Single, Dual & Triple Angle Glossmeters Declaration of Conformity
-
Elcometer 480 Model T Single, Dual & Triple Angle Glossmeters Declaration of Conformity
- Part Numbers
-
Part NumbersElcometer 480 Single, Dual & Triple Angle GlossmetersNo data found!!
-
Elcometer 480 Model B 60° Glossmeter
The Elcometer 480 Model B gloss meter is a 60° unit without memory allowing the user to take simple gloss measurements.
- Model: Model B
- Measurement Geometry: 60°
- Part Number : J480B-6
- Certification : Calibration Certificate
-
Elcometer 480 Model T 60° Glossmeter
The Elcometer 480 Model T gloss meter is a 60° unit that can quickly and accurately measure and record gloss measurements on a wide range of materials, including paint, plastic, ceramic or metal.
- Model: Model T
- Measurement Geometry: 60°
- Part Number : J480T-6
- Certification : Calibration Certificate
-
Elcometer 480 Model T 20/60° Glossmeter
The Elcometer 480 dual angle gloss meter measure both 20/60° at the same time at a rate of 10 readings per second.
- Model: Model T
- Measurement Geometry: 20/60°
- Part Number : J480T-26
- Certification : Calibration Certificate
-
Elcometer 480 Model T 20/60/85° Glossmeter
The Elcometer 480 gloss meter rapid LED technology accurately measures up to 3 gloss angles at the same time at a rate of 10 readings per second.
- Model: Model T
- Measurement Geometry: 20/60/85°
- Part Number : J480T-268
- Certification : Calibration Certificate
- Accessories
-
AccessoriesElcometer 480 Single, Dual & Triple Angle Glossmeters
- Part NumberT48024798-LC
- Part NumberT48024798-MDC
- Part NumberT48024798-HC
- Part NumberT48024798-MRC
- Part NumberT48024798-SH
- Part NumberT48025004
- Part NumberT99923535
- Part NumberT99925002
Welcome to Elcometer.tv
Your ultimate training channel
- Home
- Elcometer 480 Single, Dual & Triple Angle Glossmeters
Elcometer 480 Single, Dual & Triple Angle Glossmeters
- Industrial Finishing
The Elcometer 480 range of handheld glossmeters combine accuracy, repeatability and reproducibility with functionality allowing you to measure Gloss, % Reflectance & Haze with ease.
Accurate
- Date and time stamped readings
- Differential mode with pass/fail
- Repeatable & reproducible readings
- 40 user definable limit standards
Efficient
- Small, robust & ergonomic
- Multiple angles; 20°, 60°, 85°
- Display readings, statistics, graphs & batch review
- Standard, auto repeat and scan modes
- Automatic gauge & tile diagnostics
- Auto calibration tile recognition via RFID*
*Radio Frequency Identification; European Patent Number: 2906904
Powerful
- USB & Bluetooth® data output
- PC, iPhone or Android™ compatible
- 40,000 reading memory in up to 2,500 batches
- 3 - 10 readings per second
Summary
Elcometer 480 Single, Dual & Triple Angle Glossmeters
Using state-of-the-art design and manufacturing techniques, the Elcometer 480 Glossmeters quickly and accurately measure and record gloss measurements on a wide range of materials, including paint, plastic, ceramic or metal.
The Elcometer 480 gloss meter rapid LED technology accurately measures up to 3 gloss angles at the same time at a rate of 10 readings per second. Gloss measurements can be instantly transferred from the glossmeter to PC, iPhone, Android™ or other mobile devices via USB or Bluetooth®.
Downloads-
Elcometer 480 Single, Dual & Triple Angle Glossmeter Multi-Lingual Instruction Manual
-
Elcometer 480 Single, Dual & Triple Angle Glossmeter Datasheet
-
Elcometer 480 Model B Single, Dual & Triple Angle Glossmeters Declaration of Conformity
-
Elcometer 480 Model T Single, Dual & Triple Angle Glossmeters Declaration of Conformity
Key Features
Elcometer 480 Single, Dual & Triple Angle Glossmeters
The Model Range
The Elcometer 480 Glossmeter is available as either a simple entry level 60° glossmeter or state of the art Single, Dual or Triple angle gloss meter variants.
The Elcometer 480 Glossmeter is available with (Model T) or without (Model B) memory.
The Elcometer 480 Model B gloss meter is a 60° unit, Model T gloss meters are available as single, dual or triple angle variants with %Reflectance and Haze.
Accuracy & Repeatability
Advanced electronics and a superior optical design combines highly accurate, repeatable and reproducible measurements with industry leading inter-instrument agreement - across the Elcometer 480 Glossmeter’s entire 0-2,000GU range.
Range: 0-10GU 10-100GU 100-2000GU
Repeatability: ±0.1GU ±0.2GU ±0.2%
Reproducibility: ±0.2GU ±0.5GU ±0.5%
Calibration and Diagnostics
Every Elcometer 480 Gloss Meter Gloss Tile is fitted with an RFID (radio frequency identification) tag which allows automatic identification of the tile's serial number and calibration data when the tile is attached to the base of the glossmeter.
Additional calibration tiles are available from the range of Elcometer 480 glossmeter accessories. View accessories to find out more.
Measurement Speed
The Elcometer 480 Glossmeter's rapid LED technology accurately and repeatably measures up to 3 angles at the same time.
Standard Mode: 1+ reading per second, (70+ readings per minute)>< 0.3 seconds per angle
Auto Repeat Mode: 3 readings per second, (180 readings per minute); ~ 0.1 seconds per angle
Scan Mode: 10 readings per second, (600 readings per minute); ~ 0.03 seconds per angle
Display Modes
Fully customisable, scratch and solvent resistant colour LCD allows the user to display:
- Gloss, % Reflectance or Haze measurements
- Statistics
- Readings and Differential with pass/fail
- Trend Graph
- Analogue Scan Bar
Triple angle readings
Gloss, Haze & %Reflectance
Readings & user selectable statistics
Readings & differential with pass/ fail
Run chart & statistics
Readings & differential with analogue scan bar
Standard, Auto Repeat & Scan Modes
No two inspections are the same. It is for this reason that the Elcometer 480 Glossmeter is equipped with three gloss measurement modes:
Standard Mode: Press the measure button to take an individual spot gloss measurement.
Auto Repeat Mode: When the glossmeter is slid over the surface a measurement of all three angles is automatically taken at a user definable rate between 10 - 180 readings per minute. When enabled all the individual readings are stored into memory.
Scan Mode: As the glossmeter slides over the entire surface area, the gauge measures all three gloss angles at a continuous rate of 10 readings per second. When stopped, the glossmeter displays and stores the average, highest and lowest gloss values - ideal for checking a sample's overall uniformity.Standard Mode
Auto Repeat Mode
Scan Mode
Memory and Batching
Store 40,000 date and timed stamped readings in up to 2,500 user definable alpha-numeric batches.
Readings can be transferred to PC, iPhone, Android™ or other mobile devices via USB or Bluetooth® for instant reporting using ElcoMaster® software.
Limit Standards and Differential Mode with Pass/Fail
When visual appearance is critical Master Standards are created. These are generated and approved by the customer and then used by manufacturers as part of their quality control inspection regime. As these Master Standards have been visually approved they often do not have numerical gloss values assigned.
In order to avoid subjectivity between inspectors, the Elcometer 480 Glossmeter can automatically generate and store the nominal (target), highest & lowest acceptable gloss values (Limits) from the Master Standard.
Up to 40 Limits for each customer’s Master Standards can be stored within, and recalled from, the gauge’s ‘Limit Standards’ memory.
When Limit Standards are used in combination with the gauge’s Differential Mode, the Elcometer 480 Gloss Meter displays the measurement value together with the difference from the nominal (target) value.
Readings outside the Limit Standards are displayed in red, providing quick Pass/Fail analysis.
Due to the Elcometer 480 Glossmeters industry leading inter-instrument agreement, once a Master Standard Limit has been created, the gauge can transfer these values to other Elcometer 480 glossmeters, via the ElcoMaster® Software’s Library of Limit Standards, at any time.
Information from multiple glossmeters can be combined into a single inspection report within ElcoMaster® Software, ideal for multiple production and assembly lines.
Create instant reports with ElcoMaster®
What you do with the collected data is just as important as taking the readings themselves.
Data transferred to ElcoMaster® includes;
- 20° 60° & 85° Gloss Units (GU)
- Haze Unit (HU)
- % Reflectance (%)
- Date & time for each reading
- Limit Standard values
- Batch information & statistics
- Calibration information including date/time, serial number & tile values
Elcometer 480 Model T: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPhone 4, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (4th and 5th generation).“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.
Product FeaturesElcometer 480 Single, Dual & Triple Angle GlossmetersModel B Model T Measurement geometries 60° 60°, 20/60° or 20/60/85°* Measurement Units GU GU, HU1 & % Fast, accurate reading rate Repeatable & reproducible measurements Easy to use menu structure; in 30+ languages Tough, impact, waterproof & dust resistant Scratch & solvent resistant display; 2.4” (6cm) TFT Rotating display: auto, 0°, 180° Ambient light sensor; with adjustable auto brightness Data Output USB live readings USB batch download Bluetooth®: to PC, iOS or Android™ mobile devices USB & battery powered Calibration certificate Manual gauge calibration Auto gauge calibration; via RFID tagging of integrated calibration tile2 On screen statistics Number of readings, Mean (average), Standard deviation, Highest reading, Lowest reading, Range Coefficient of variation, Nominal value, High Limit value, Low Limit value Number above high limit, Number below low limit Measurement modes Standard Mode Auto Repeat Mode; programmable 10-180 readings per minute Scan Mode; 10 readings per second Differential Mode with Pass/ Fail mode; Limit Standards; up to 40 programmable standards Gauge & batch specific standard limits Gauge memory 40,000 readings in up to 2,500 batches Alpha-numeric batch names Fixed Batch Size Mode Date & time stamp Gauge auto diagnostics Display modes; user selectable Readings; gloss, % reflectance, haze1 Selected statistics Trend graph; last 20 readings Scan bar display Readings & differential (with pass/fail) Delete last reading 2 year extended warranty3 * Dependant on model
1 Haze on Dual and Triple models only
2 Radio Frequency Identification; European Patent Number: 2906904
3 The Elcometer 480 is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase.
Technical SpecificationElcometer 480 Single, Dual & Triple Angle GlossmetersPart Number Description Certificate J480B-6 Elcometer 480 Model B 60° Glossmeter J480T-6 Elcometer 480 Model T 60° Glossmeter J480T-26 Elcometer 480 Model T 20/60° Glossmeter J480T-268 Elcometer 480 Model T 20/60/85° Glossmeter Display information 2.4’’ (6cm) QVGA colour TFT display, 320 x 240 pixels Power Supply USB (via PC) or 2x AA batteries (~50,000 readings) 20° 60° 85° Measurement Dimensions 20°: 10 x 10mm 60°: 8 x 16mm 85°: 4 x 55mm Measurement Range 20°: 0 - 2000GU 60°: 0 - 1000GU 85°:0 - 160GU Repeatability 20°: ± 0.1GU (0 - 10GU) 60°: ±0.2GU (10 - 100GU) 85°: ±0.2%: 100 - 2000GU Reproducibility 20°: ± 0.2GU (0 - 10GU) 60°: ±0.5GU (10 - 100GU) 85°: ±0.5% 100 - 2000GU Resolution Gloss 0.01% (0 - 10%), 0.1% (10 - 100%) % Reflectance 0.1 HU (0 - 100HU), 1 HU (>100HU) Haze -10°C to 50°C (14 to 122°F) Operating Temperature -10°C to 50°C (14 to 122°F) Relative Humidity 0 - 85%RH Dimensions 68 x 155 x 50mm (2.68 x 6.10 x 1.97ˮ) Weight 534g (1lb 3oz) [including batteries] Packing List Elcometer 480 Glossmeter, integrated calibration tile, calibration certificates for gauge & calibration tile, 2x AA batteries, wrist strap, operating instructions, plastic carry case, ElcoMaster® Software (Model T) and USB cable (Model T) Part Number Description Certificate J480B-6 Elcometer 480 Model B 60° Glossmeter J480T-6 Elcometer 480 Model T 60° Glossmeter J480T-26 Elcometer 480 Model T 20/60° Glossmeter J480T-268 Elcometer 480 Model T 20/60/85° Glossmeter Display information 2.4’’ (6cm) QVGA colour TFT display, 320 x 240 pixels Power Supply USB (via PC) or 2x AA batteries (~50,000 readings) Measurement Dimensions 20°: 10 x 10mm, 60°: 8 x 16mm, 85°: 4 x 55mm Measurement Range 20°: 0 - 2000GU, 60°: 0 - 1000GU, 85°:0 - 160GU Repeatability 20°: ± 0.1GU (0 - 10GU), 60°: ±0.2GU (10 - 100GU), 85°: ±0.2%: 100 - 2000GU Reproducibility 20°: ± 0.2GU (0 - 10GU), 60°: ±0.5GU (10 - 100GU), 85°: ±0.5% 100 - 2000GU Gloss 0.1 GU (0 - 100GU), 1 GU (>100GU) % Reflectance 0.01% (0 - 10%), 0.1% (10 - 100%) Haze 0.1 HU (0 - 100HU), 1 HU (>100HU) Operating Temperature -10°C to 50°C (14 to 122°F) Relative Humidity 0 - 85%RH Dimensions 68 x 155 x 50mm (2.68 x 6.10 x 1.97ˮ) Weight 534g (1lb 3oz) [including batteries] Packing List Elcometer 480 Glossmeter, integrated calibration tile, calibration certificates for gauge & calibration tile, 2x AA batteries, wrist strap, operating instructions, plastic carry case, ElcoMaster® Software (Model T) and USB cable (Model T) ● Certificate supplied as standard.StandardsElcometer 480 Single, Dual & Triple Angle GlossmetersAS/NZS 1580.602.2, ASTM C584, ASTM D523, ASTM D1455, ASTM D2457, ASTM D4039, ASTM E430, ASTM E2387, BS 3900 D5, DIN 67530, ECCA T2, EN 12373-11, EN 13523-2, ISO 7668, ISO 2813, ISO 13803, JIS K 5600-4-7, JIS Z 8741, TAPPI T 653 (20°)
Standards in grey have been superseded but are still recognised in some industries.
Part NumbersElcometer 480 Single, Dual & Triple Angle GlossmetersNo data found!!-
Elcometer 480 Model B 60° Glossmeter
The Elcometer 480 Model B gloss meter is a 60° unit without memory allowing the user to take simple gloss measurements.
- Model: Model B
- Measurement Geometry: 60°
- Part Number : J480B-6
- Certification : Calibration Certificate
-
Elcometer 480 Model T 60° Glossmeter
The Elcometer 480 Model T gloss meter is a 60° unit that can quickly and accurately measure and record gloss measurements on a wide range of materials, including paint, plastic, ceramic or metal.
- Model: Model T
- Measurement Geometry: 60°
- Part Number : J480T-6
- Certification : Calibration Certificate
-
Elcometer 480 Model T 20/60° Glossmeter
The Elcometer 480 dual angle gloss meter measure both 20/60° at the same time at a rate of 10 readings per second.
- Model: Model T
- Measurement Geometry: 20/60°
- Part Number : J480T-26
- Certification : Calibration Certificate
-
Elcometer 480 Model T 20/60/85° Glossmeter
The Elcometer 480 gloss meter rapid LED technology accurately measures up to 3 gloss angles at the same time at a rate of 10 readings per second.
- Model: Model T
- Measurement Geometry: 20/60/85°
- Part Number : J480T-268
- Certification : Calibration Certificate
Welcome to Elcometer.tv
Your ultimate training channelAccessoriesElcometer 480 Single, Dual & Triple Angle Glossmeters- Part Number: T48024798-LC
- Part Number: T48024798-MDC
- Part Number: T48024798-HC
- Part Number: T48024798-MRC
- Part Number: T48024798-SH
- Part Number: T48025004
- Part Number: T99923535
- Part Number: T99925002
-
-