Elcometer CG100 Corrosion Thickness Gauge

CG100B
CG100ABDL

Top of the range and easy to use, the Elcometer CG100 Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.

  • Summary
    • Summary

    • Elcometer CG100 Corrosion Thcikness Gauge

      Intelligent

      User definable limits for pass/fail indication

      Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.

      Dual Element Transducer

      Powerful

      Store each measurement for further analysis

      Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into ElcoMaster® Software for further analysis and reporting.

      Elcometer CG100 Ultrasonic Corrosion Thickness Gauge

      Versatile

      Able to measure coating and material thickness

      The Elcometer CG100 has the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.

      cg100-transparent-KEY-FEATURES

      Customisable

      Choose & customise the reading display

      The Elcometer CG100 range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the CG100ABDL and CG100ABDL+.

      The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.

      • Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
      • Manual or automatic gain control (AGC) with adjustable 110dB range
      • Gate control
      • Threshold adjustment
      • 64 User defined setups
      • Multiple language display
      • Multiple calibration and material selection options
      • High speed scan mode: 250 readings per second (CG100100B and CG100BDL), 50 readings per second (CG100ABDL and CG100ABDL+)
      • A-Scan portrait & landscape views (CG100ABDL+ only)
      • Differential and minimal thickness alarm modes
      • Data output and storage: 4GB internal memory
      • Download to ElcoMaster® data management software
  • Key Features
    • Key Features

      Elcometer CG100 Corrosion Thickness Gauge

      CG100 Features Explained

      Repeatability / Stability Indicator

      Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

      High Speed Scan with Minimum Thickness Display

      By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

      Differential Mode

      Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

      Limit Alarm Mode

      The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.

      V-Path Correction

      Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness

      Measurement Modes Explained

      CG100-PE-Mode

      Pulse - Echo Mode (PE):

      The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

      CG100-EE-Mode_1

      Echo - Echo Mode (EE):

      Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.

      CG100-PEPT-Mode

      Pulse - Echo Temp Comp Mode  (PETP):

      Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations. 

      CG100-EEV-Mode

      Echo - Echo Verify Mode (EEV):

      The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.

      CG100-CT-Mode

      Coating Only Mode (CT):

      Displays the thickness of the coating applied to the material.

      CG100-PECT-Mode

      Pulse - Echo Coating Mode (PECT):

      Displays both the material thickness (PE) and the coating thickness (CT) at the same time.

      CG100-FLAW-Mode

      Basic Flaw Mode (FLAW MODE):

      Basic prove-up flaw detection using single element angle beam transducers is available on the CG100ABDL and CG100ABDL+ corrosion thickness gauges.

      Display Modes Explained

      CG70-B-Scan_2

      Material Thickness Digits Display:

      The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).

      Scan Bar Display:

      A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

      B-Scan Display:

      A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

      CG70-A-Scan_1

      A-Scan Display; Full Wave (RF):*

      The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

      A-Scan Display; Rectified (+ or -):*

      Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

       

      * Available on CG100ABDL and CG100ABDL+ Models only

  • Product Features
    • Product Features
      Elcometer CG100 Corrosion Thickness Gauge
      Model CG100B CG100BDL CG100ABDL CG100ABDL+
      Display Mode
      Material thickness digits display
      B-Scan cross sectional display
      Combined B-Scan and digits display
      Coating Thickness Display
      Scan Bar Display
      A-Scan Display
      + Rectified, - Rectified, Full Waveform (RF)
      + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
      Measurement Range1
      PE: 0.63 - 1219.2mm (0.025 - 48”)
      PETP: 0.63 - 1219.2mm (0.025 - 48”)
      EE: 2.54 - 152.4mm (0.100 - 6.0“)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      CT: 0.01 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm (0.025 - 48”)
      PE: 0.63 - 1219.2mm (0.025 - 48”)
      PETP: 0.63 - 1219.2mm (0.025 - 48”)
      EE: 2.54 - 152.4mm (0.100 - 6.0“)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      CT: 0.01 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm (0.025 - 48”)
      PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
      EE: 2.54 - 152.4mm (0.100 - 6.0”)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      , CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 30,480mm (0.025 - 1200”)
      PECT: 0.01 - 2.54mm (0.001 - 0.100”)
      PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
      EE: 2.54 - 152.4mm (0.100 - 6.0”)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      , CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 30,480mm (0.025 - 1200”)
      PECT: 0.01 - 2.54mm (0.001 - 0.100”)
      Measurement Rate
      Manual
      8 readings per second
      8 readings per second
      8 readings per second
      8 readings per second
      Scan Mode
      250 readings per second
      250 readings per second
      50 readings per second
      50 readings per second
      Scan bar display
      10 readings per second
      10 readings per second
      10 readings per second
      10 readings per second
      Measurement Resolution
      0.01mm (0.001”)
      0.01mm (0.001”)
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      Velocity Calibration Range
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      Additional Features
      Additional Features
      Differential Mode
      Limit alarm mode
      B-Scan Display Speed
      10 to 200 readings per second
      10 to 200 readings per second
      10 to 200 readings per second
      10 to 200 readings per second
      Flaw Mode
      Basic prove-up flaw detection using single element angle beam transducers
      Basic prove-up flaw detection using single element angle beam transducers
      Calibration Setups
      64 user-definable setups transferable to and from a PC archive
      64 user-definable setups transferable to and from a PC archive
      64 user-definable setups transferable to and from a PC archive
      64 user-definable setups transferable to and from a PC archive
      Gates
      3 fully adjustable gates: start, stop, width & threshold
      3 fully adjustable gates: start, stop, width & threshold
      Damping
      Adjustable damping (50 - 1500ohms)
      Adjustable damping (50 - 1500ohms)
      Pulser Type
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Gain
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Manual or automatic gain control (AGC) with 110dB range (limited)
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Timing
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Memory and Data Logging
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Calibration Options
      1 - point
      2 - point
      Material selection
      Velocity (speed of sound)
      Transducer Probe Type
      Dual element
      Dual element
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      Transducer Frequency Range
      1 - 10MHz
      1 - 10MHz
      1 - 20MHz
      1 - 20MHz
      Transducer Recognition
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      Automatic & manual - selectable from a list
      V-path / dual path error correction
      Automatic
      Automatic
      Automatic
      Automatic
      Probe Zero
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Automatic & manual (via integrated probe disk)
      Display
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      •1/4 VGA AMOLED colour display
      •57.6 x 43.2mm (2.27 x 1.78”) viewable area
      •Landscape Mode
      Display Refresh Rate
      25Hz
      25Hz
      25Hz
      60Hz
      Units (selectable)
      mm or inches
      mm or inches
      mm or inches
      mm or inches
      LED Backlight
      on/off/auto
      on/off/auto
      on/off/auto
      adjustable brightness
      Repeatability / Stability Indicator
      Battery Save Mode
      Auto
      Auto
      Auto
      Auto
      Display Mode
      Material thickness digits display
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      B-Scan cross sectional display
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Combined B-Scan and digits display
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Coating Thickness Display
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Scan Bar Display
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      A-Scan Display
      CG100B
      CG100BDL
      CG100ABDL
      + Rectified, - Rectified, Full Waveform (RF)
      CG100ABDL+
      + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
      Measurement Range1
      CG100B
      PE: 0.63 - 1219.2mm (0.025 - 48”)
      PETP: 0.63 - 1219.2mm (0.025 - 48”)
      EE: 2.54 - 152.4mm (0.100 - 6.0“)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      CT: 0.01 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm (0.025 - 48”)
      CG100BDL
      PE: 0.63 - 1219.2mm (0.025 - 48”)
      PETP: 0.63 - 1219.2mm (0.025 - 48”)
      EE: 2.54 - 152.4mm (0.100 - 6.0“)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      CT: 0.01 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 1219.2mm (0.025 - 48”)
      CG100ABDL
      PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
      EE: 2.54 - 152.4mm (0.100 - 6.0”)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      , CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 30,480mm (0.025 - 1200”)
      PECT: 0.01 - 2.54mm (0.001 - 0.100”)
      CG100ABDL+
      PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
      EE: 2.54 - 152.4mm (0.100 - 6.0”)
      EEV: 2.54 - 25.4mm (0.100 - 1.0”)
      , CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
      PECT: 0.63 - 30,480mm (0.025 - 1200”)
      PECT: 0.01 - 2.54mm (0.001 - 0.100”)
      Measurement Rate
      Manual
      CG100B
      8 readings per second
      CG100BDL
      8 readings per second
      CG100ABDL
      8 readings per second
      CG100ABDL+
      8 readings per second
      Scan Mode
      CG100B
      250 readings per second
      CG100BDL
      250 readings per second
      CG100ABDL
      50 readings per second
      CG100ABDL+
      50 readings per second
      Scan bar display
      CG100B
      10 readings per second
      CG100BDL
      10 readings per second
      CG100ABDL
      10 readings per second
      CG100ABDL+
      10 readings per second
      Measurement Resolution
      CG100B
      0.01mm (0.001”)
      CG100BDL
      0.01mm (0.001”)
      CG100ABDL
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      CG100ABDL+
      0.01mm (0.001”), 0.001mm (0.0001”) selectable
      Velocity Calibration Range
      CG100B
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      CG100BDL
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      CG100ABDL
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      CG100ABDL+
      309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
      Additional Features
      Additional Features
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Differential Mode
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Limit alarm mode
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      B-Scan Display Speed
      CG100B
      10 to 200 readings per second
      CG100BDL
      10 to 200 readings per second
      CG100ABDL
      10 to 200 readings per second
      CG100ABDL+
      10 to 200 readings per second
      Flaw Mode
      CG100B
      CG100BDL
      CG100ABDL
      Basic prove-up flaw detection using single element angle beam transducers
      CG100ABDL+
      Basic prove-up flaw detection using single element angle beam transducers
      Calibration Setups
      CG100B
      64 user-definable setups transferable to and from a PC archive
      CG100BDL
      64 user-definable setups transferable to and from a PC archive
      CG100ABDL
      64 user-definable setups transferable to and from a PC archive
      CG100ABDL+
      64 user-definable setups transferable to and from a PC archive
      Gates
      CG100B
      CG100BDL
      CG100ABDL
      3 fully adjustable gates: start, stop, width & threshold
      CG100ABDL+
      3 fully adjustable gates: start, stop, width & threshold
      Damping
      CG100B
      CG100BDL
      CG100ABDL
      Adjustable damping (50 - 1500ohms)
      CG100ABDL+
      Adjustable damping (50 - 1500ohms)
      Pulser Type
      CG100B
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      CG100BDL
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      CG100ABDL
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      CG100ABDL+
      Dual square wave pulsers
      Pulse repetition frequency up to 250Hz
      Gain
      CG100B
      Manual or automatic gain control (AGC) with 110dB range (limited)
      CG100BDL
      Manual or automatic gain control (AGC) with 110dB range (limited)
      CG100ABDL
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      CG100ABDL+
      Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
      Timing
      CG100B
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      CG100BDL
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      CG100ABDL
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      CG100ABDL+
      Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
      Memory and Data Logging
      CG100B
      CG100BDL
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      CG100ABDL
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      CG100ABDL+
      • 4GB internal memory
      • Sequential and grid logging
      • Alpha numeric batch identification
      • OBSTRUCT indicates inaccessible locations
      • Bitmap graphic capture and capture viewer
      Calibration Options
      1 - point
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      2 - point
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Material selection
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Velocity (speed of sound)
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Transducer Probe Type
      CG100B
      Dual element
      CG100BDL
      Dual element
      CG100ABDL
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      CG100ABDL+
      Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
      Transducer Frequency Range
      CG100B
      1 - 10MHz
      CG100BDL
      1 - 10MHz
      CG100ABDL
      1 - 20MHz
      CG100ABDL+
      1 - 20MHz
      Transducer Recognition
      CG100B
      Automatic & manual - selectable from a list
      CG100BDL
      Automatic & manual - selectable from a list
      CG100ABDL
      Automatic & manual - selectable from a list
      CG100ABDL+
      Automatic & manual - selectable from a list
      V-path / dual path error correction
      CG100B
      Automatic
      CG100BDL
      Automatic
      CG100ABDL
      Automatic
      CG100ABDL+
      Automatic
      Probe Zero
      CG100B
      Automatic & manual (via integrated probe disk)
      CG100BDL
      Automatic & manual (via integrated probe disk)
      CG100ABDL
      Automatic & manual (via integrated probe disk)
      CG100ABDL+
      Automatic & manual (via integrated probe disk)
      Display
      CG100B
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      CG100BDL
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      CG100ABDL
      •1/8 VGA (greyscale)
      • 62 x 45.7mm (2.4 x 1.8”) viewable area
      CG100ABDL+
      •1/4 VGA AMOLED colour display
      •57.6 x 43.2mm (2.27 x 1.78”) viewable area
      •Landscape Mode
      Display Refresh Rate
      CG100B
      25Hz
      CG100BDL
      25Hz
      CG100ABDL
      25Hz
      CG100ABDL+
      60Hz
      Units (selectable)
      CG100B
      mm or inches
      CG100BDL
      mm or inches
      CG100ABDL
      mm or inches
      CG100ABDL+
      mm or inches
      LED Backlight
      CG100B
      on/off/auto
      CG100BDL
      on/off/auto
      CG100ABDL
      on/off/auto
      CG100ABDL+
      adjustable brightness
      Repeatability / Stability Indicator
      CG100B
      CG100BDL
      CG100ABDL
      CG100ABDL+
      Battery Save Mode
      CG100B
      Auto
      CG100BDL
      Auto
      CG100ABDL
      Auto
      CG100ABDL+
      Auto

      1 Measuring range & accuracy depends on material, surface conditions and the transducer selected

  • Technical Information
    • Technical Specification
      Elcometer CG100 Corrosion Thickness Gauge
      Part Number Description Certificate
      CG100B Elcometer CG100B Corrosion Thickness Gauge
      Test Certificate supplied as standard
      CG100BDL Elcometer CG100BDL Corrosion Thickness Gauge
      Test Certificate supplied as standard
      CG100ABDL Elcometer CG100ABDL Corrosion Thickness Gauge
      Test Certificate supplied as standard
      CG100ABDL+ Elcometer CG100ABDL+ Corrosion Thickness Gauge
      Test Certificate supplied as standard
      Transducer Probe Type Dual Element
      Measurement Accuracy1 0.01mm (0.001”)
      Memory 4GB Internal Memory
      Operating Temperature -10 to 60ºC (14 to 140ºF)
      Data Output USB
      Power Supply 3 x AA batteries and via USB
      Battery Life2 Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs
      Gauge Weight 383g (13.5oz) - including batteries
      Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
      Packing List Elcometer NDT CG100 gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, ElcoMaster® software, transfer cable
      1Measuring range & accuracy depends on material, surface conditions and the transducer selected
      2Approximate battery life, when in continuous measurement mode.
      ● Test Certificate supplied as standard.
  • Standards
    • Standards
      Elcometer CG100 Corrosion Thickness Gauge

      ASTM E 797, EN 14127, EN 15317

  • Downloads
    • Downloads
        • Elcometer NDT Model CG100B, CG100BDL & CG100ABDL Instruction Manual

        • Elcometer NDT Model CG100ABDL+ Instruction Manual

        • Elcometer CG100 Corrosion Thickness Gauges Datasheet

        • CG100B Corrosion Thickness Gauges Declaration of Conformity

        • CG100BDL Corrosion Thickness Gauges Declaration of Conformity

        • CG100ABDL Corrosion Thickness Gauges Declaration of Conformity

        • CG100ABDL+ Corrosion Thickness Gauges Declaration of Conformity

  • Part Numbers
    • Part Numbers
      Elcometer CG100 Corrosion Thickness Gauge
      • Elcometer CG100B Corrosion Thickness Gauge
        • Part Number : CG100B
      • Elcometer CG100BDL Corrosion Thickness Gauge
        • Part Number : CG100BDL
      • Elcometer CG100ABDL Corrosion Thickness Gauge
        • Gates: 3 fully adjustable gates: start, stop, width & threshold
        • Damping: Adjustable damping (50 - 1500ohms)
        • Part Number : CG100ABDL
      • Elcometer CG100ABDL+ Corrosion Thickness Gauge
        • Gates: 3 fully adjustable gates: start, stop, width & threshold
        • Damping: Adjustable damping (50 - 1500ohms)
        • Part Number : CG100ABDL+
  • Accessories
    • Accessories
      Elcometer CG100 Corrosion Thickness Gauge
      • Part Number: TC-24034-1
      • Part Number: TC-24034-2
      • Part Number: TC-24034-3
      • Part Number: TC-24034-9
      • Part Number: TL-24030-1
      • Part Number: TL-24030-2
      • Part Number: TL-24030-3
      • Part Number: TL-24030-6
      • Part Number: TL-24031
      • Part Number: TL-24032

Elcometer CG100 Corrosion Thickness Gauge

CG100B
CG100ABDL

Top of the range and easy to use, the Elcometer CG100 Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.

Elcometer CG100 Corrosion Thcikness Gauge

Intelligent

User definable limits for pass/fail indication

Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.

Dual Element Transducer

Powerful

Store each measurement for further analysis

Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into ElcoMaster® Software for further analysis and reporting.

Elcometer CG100 Ultrasonic Corrosion Thickness Gauge

Versatile

Able to measure coating and material thickness

The Elcometer CG100 has the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.

cg100-transparent-KEY-FEATURES

Customisable

Choose & customise the reading display

The Elcometer CG100 range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the CG100ABDL and CG100ABDL+.

Summary

Elcometer CG100 Corrosion Thickness Gauge

The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.

  • Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
  • Manual or automatic gain control (AGC) with adjustable 110dB range
  • Gate control
  • Threshold adjustment
  • 64 User defined setups
  • Multiple language display
  • Multiple calibration and material selection options
  • High speed scan mode: 250 readings per second (CG100100B and CG100BDL), 50 readings per second (CG100ABDL and CG100ABDL+)
  • A-Scan portrait & landscape views (CG100ABDL+ only)
  • Differential and minimal thickness alarm modes
  • Data output and storage: 4GB internal memory
  • Download to ElcoMaster® data management software
Downloads
    • Elcometer NDT Model CG100B, CG100BDL & CG100ABDL Instruction Manual

    • Elcometer NDT Model CG100ABDL+ Instruction Manual

    • Elcometer CG100 Corrosion Thickness Gauges Datasheet

    • CG100B Corrosion Thickness Gauges Declaration of Conformity

    • CG100BDL Corrosion Thickness Gauges Declaration of Conformity

    • CG100ABDL Corrosion Thickness Gauges Declaration of Conformity

    • CG100ABDL+ Corrosion Thickness Gauges Declaration of Conformity

Key Features

Elcometer CG100 Corrosion Thickness Gauge

CG100 Features Explained

Repeatability / Stability Indicator

Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.

High Speed Scan with Minimum Thickness Display

By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).

Differential Mode

Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.

Limit Alarm Mode

The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.

V-Path Correction

Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness

Measurement Modes Explained

CG100-PE-Mode

Pulse - Echo Mode (PE):

The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.

CG100-EE-Mode_1

Echo - Echo Mode (EE):

Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.

CG100-PEPT-Mode

Pulse - Echo Temp Comp Mode  (PETP):

Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations. 

CG100-EEV-Mode

Echo - Echo Verify Mode (EEV):

The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.

CG100-CT-Mode

Coating Only Mode (CT):

Displays the thickness of the coating applied to the material.

CG100-PECT-Mode

Pulse - Echo Coating Mode (PECT):

Displays both the material thickness (PE) and the coating thickness (CT) at the same time.

CG100-FLAW-Mode

Basic Flaw Mode (FLAW MODE):

Basic prove-up flaw detection using single element angle beam transducers is available on the CG100ABDL and CG100ABDL+ corrosion thickness gauges.

Display Modes Explained

CG70-B-Scan_2

Material Thickness Digits Display:

The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).

Scan Bar Display:

A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.

B-Scan Display:

A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.

CG70-A-Scan_1

A-Scan Display; Full Wave (RF):*

The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.

A-Scan Display; Rectified (+ or -):*

Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.

 

* Available on CG100ABDL and CG100ABDL+ Models only

Product Features
Elcometer CG100 Corrosion Thickness Gauge
Model CG100B CG100BDL CG100ABDL CG100ABDL+
Display Mode
Material thickness digits display
B-Scan cross sectional display
Combined B-Scan and digits display
Coating Thickness Display
Scan Bar Display
A-Scan Display
+ Rectified, - Rectified, Full Waveform (RF)
+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
Measurement Range1
PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)
PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)
PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)
PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)
Measurement Rate
Manual
8 readings per second
8 readings per second
8 readings per second
8 readings per second
Scan Mode
250 readings per second
250 readings per second
50 readings per second
50 readings per second
Scan bar display
10 readings per second
10 readings per second
10 readings per second
10 readings per second
Measurement Resolution
0.01mm (0.001”)
0.01mm (0.001”)
0.01mm (0.001”), 0.001mm (0.0001”) selectable
0.01mm (0.001”), 0.001mm (0.0001”) selectable
Velocity Calibration Range
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
Additional Features
Additional Features
Differential Mode
Limit alarm mode
B-Scan Display Speed
10 to 200 readings per second
10 to 200 readings per second
10 to 200 readings per second
10 to 200 readings per second
Flaw Mode
Basic prove-up flaw detection using single element angle beam transducers
Basic prove-up flaw detection using single element angle beam transducers
Calibration Setups
64 user-definable setups transferable to and from a PC archive
64 user-definable setups transferable to and from a PC archive
64 user-definable setups transferable to and from a PC archive
64 user-definable setups transferable to and from a PC archive
Gates
3 fully adjustable gates: start, stop, width & threshold
3 fully adjustable gates: start, stop, width & threshold
Damping
Adjustable damping (50 - 1500ohms)
Adjustable damping (50 - 1500ohms)
Pulser Type
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Gain
Manual or automatic gain control (AGC) with 110dB range (limited)
Manual or automatic gain control (AGC) with 110dB range (limited)
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Timing
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Memory and Data Logging
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Calibration Options
1 - point
2 - point
Material selection
Velocity (speed of sound)
Transducer Probe Type
Dual element
Dual element
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
Transducer Frequency Range
1 - 10MHz
1 - 10MHz
1 - 20MHz
1 - 20MHz
Transducer Recognition
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
Automatic & manual - selectable from a list
V-path / dual path error correction
Automatic
Automatic
Automatic
Automatic
Probe Zero
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Automatic & manual (via integrated probe disk)
Display
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
•1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape Mode
Display Refresh Rate
25Hz
25Hz
25Hz
60Hz
Units (selectable)
mm or inches
mm or inches
mm or inches
mm or inches
LED Backlight
on/off/auto
on/off/auto
on/off/auto
adjustable brightness
Repeatability / Stability Indicator
Battery Save Mode
Auto
Auto
Auto
Auto
Display Mode
Material thickness digits display
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
B-Scan cross sectional display
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Combined B-Scan and digits display
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Coating Thickness Display
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Scan Bar Display
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
A-Scan Display
CG100B
CG100BDL
CG100ABDL
+ Rectified, - Rectified, Full Waveform (RF)
CG100ABDL+
+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape views
Measurement Range1
CG100B
PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)
CG100BDL
PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)
CG100ABDL
PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)
CG100ABDL+
PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)
Measurement Rate
Manual
CG100B
8 readings per second
CG100BDL
8 readings per second
CG100ABDL
8 readings per second
CG100ABDL+
8 readings per second
Scan Mode
CG100B
250 readings per second
CG100BDL
250 readings per second
CG100ABDL
50 readings per second
CG100ABDL+
50 readings per second
Scan bar display
CG100B
10 readings per second
CG100BDL
10 readings per second
CG100ABDL
10 readings per second
CG100ABDL+
10 readings per second
Measurement Resolution
CG100B
0.01mm (0.001”)
CG100BDL
0.01mm (0.001”)
CG100ABDL
0.01mm (0.001”), 0.001mm (0.0001”) selectable
CG100ABDL+
0.01mm (0.001”), 0.001mm (0.0001”) selectable
Velocity Calibration Range
CG100B
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
CG100BDL
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
CG100ABDL
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
CG100ABDL+
309.88 - 18,542m/s (0.0122 - 0.7300in/µs)
Additional Features
Additional Features
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Differential Mode
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Limit alarm mode
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
B-Scan Display Speed
CG100B
10 to 200 readings per second
CG100BDL
10 to 200 readings per second
CG100ABDL
10 to 200 readings per second
CG100ABDL+
10 to 200 readings per second
Flaw Mode
CG100B
CG100BDL
CG100ABDL
Basic prove-up flaw detection using single element angle beam transducers
CG100ABDL+
Basic prove-up flaw detection using single element angle beam transducers
Calibration Setups
CG100B
64 user-definable setups transferable to and from a PC archive
CG100BDL
64 user-definable setups transferable to and from a PC archive
CG100ABDL
64 user-definable setups transferable to and from a PC archive
CG100ABDL+
64 user-definable setups transferable to and from a PC archive
Gates
CG100B
CG100BDL
CG100ABDL
3 fully adjustable gates: start, stop, width & threshold
CG100ABDL+
3 fully adjustable gates: start, stop, width & threshold
Damping
CG100B
CG100BDL
CG100ABDL
Adjustable damping (50 - 1500ohms)
CG100ABDL+
Adjustable damping (50 - 1500ohms)
Pulser Type
CG100B
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
CG100BDL
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
CG100ABDL
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
CG100ABDL+
Dual square wave pulsers
Pulse repetition frequency up to 250Hz
Gain
CG100B
Manual or automatic gain control (AGC) with 110dB range (limited)
CG100BDL
Manual or automatic gain control (AGC) with 110dB range (limited)
CG100ABDL
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
CG100ABDL+
Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slope
Timing
CG100B
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
CG100BDL
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
CG100ABDL
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
CG100ABDL+
Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizer
Memory and Data Logging
CG100B
CG100BDL
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
CG100ABDL
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
CG100ABDL+
• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer
Calibration Options
1 - point
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
2 - point
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Material selection
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Velocity (speed of sound)
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Transducer Probe Type
CG100B
Dual element
CG100BDL
Dual element
CG100ABDL
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
CG100ABDL+
Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and Pencil
Transducer Frequency Range
CG100B
1 - 10MHz
CG100BDL
1 - 10MHz
CG100ABDL
1 - 20MHz
CG100ABDL+
1 - 20MHz
Transducer Recognition
CG100B
Automatic & manual - selectable from a list
CG100BDL
Automatic & manual - selectable from a list
CG100ABDL
Automatic & manual - selectable from a list
CG100ABDL+
Automatic & manual - selectable from a list
V-path / dual path error correction
CG100B
Automatic
CG100BDL
Automatic
CG100ABDL
Automatic
CG100ABDL+
Automatic
Probe Zero
CG100B
Automatic & manual (via integrated probe disk)
CG100BDL
Automatic & manual (via integrated probe disk)
CG100ABDL
Automatic & manual (via integrated probe disk)
CG100ABDL+
Automatic & manual (via integrated probe disk)
Display
CG100B
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
CG100BDL
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
CG100ABDL
•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area
CG100ABDL+
•1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape Mode
Display Refresh Rate
CG100B
25Hz
CG100BDL
25Hz
CG100ABDL
25Hz
CG100ABDL+
60Hz
Units (selectable)
CG100B
mm or inches
CG100BDL
mm or inches
CG100ABDL
mm or inches
CG100ABDL+
mm or inches
LED Backlight
CG100B
on/off/auto
CG100BDL
on/off/auto
CG100ABDL
on/off/auto
CG100ABDL+
adjustable brightness
Repeatability / Stability Indicator
CG100B
CG100BDL
CG100ABDL
CG100ABDL+
Battery Save Mode
CG100B
Auto
CG100BDL
Auto
CG100ABDL
Auto
CG100ABDL+
Auto

1 Measuring range & accuracy depends on material, surface conditions and the transducer selected

Technical Specification
Elcometer CG100 Corrosion Thickness Gauge
Part Number Description Certificate
CG100B Elcometer CG100B Corrosion Thickness Gauge
Test Certificate supplied as standard
CG100BDL Elcometer CG100BDL Corrosion Thickness Gauge
Test Certificate supplied as standard
CG100ABDL Elcometer CG100ABDL Corrosion Thickness Gauge
Test Certificate supplied as standard
CG100ABDL+ Elcometer CG100ABDL+ Corrosion Thickness Gauge
Test Certificate supplied as standard
Transducer Probe Type Dual Element
Measurement Accuracy1 0.01mm (0.001”)
Memory 4GB Internal Memory
Operating Temperature -10 to 60ºC (14 to 140ºF)
Data Output USB
Power Supply 3 x AA batteries and via USB
Battery Life2 Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs
Gauge Weight 383g (13.5oz) - including batteries
Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”)
Packing List Elcometer NDT CG100 gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, ElcoMaster® software, transfer cable
1Measuring range & accuracy depends on material, surface conditions and the transducer selected
2Approximate battery life, when in continuous measurement mode.
● Test Certificate supplied as standard.
Standards
Elcometer CG100 Corrosion Thickness Gauge

ASTM E 797, EN 14127, EN 15317

Part Numbers
Elcometer CG100 Corrosion Thickness Gauge
  • Elcometer CG100B Corrosion Thickness Gauge
    • Part Number : CG100B
  • Elcometer CG100BDL Corrosion Thickness Gauge
    • Part Number : CG100BDL
  • Elcometer CG100ABDL Corrosion Thickness Gauge
    • Gates: 3 fully adjustable gates: start, stop, width & threshold
    • Damping: Adjustable damping (50 - 1500ohms)
    • Part Number : CG100ABDL
  • Elcometer CG100ABDL+ Corrosion Thickness Gauge
    • Gates: 3 fully adjustable gates: start, stop, width & threshold
    • Damping: Adjustable damping (50 - 1500ohms)
    • Part Number : CG100ABDL+
   
Accessories
Elcometer CG100 Corrosion Thickness Gauge
  • Part Number: TC-24034-1
  • Part Number: TC-24034-2
  • Part Number: TC-24034-3
  • Part Number: TC-24034-9
  • Part Number: TL-24030-1
  • Part Number: TL-24030-2
  • Part Number: TL-24030-3
  • Part Number: TL-24030-6
  • Part Number: TL-24031
  • Part Number: TL-24032