

Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
- Industrial Finishing

The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) offers the same feature as the Active Cool Closed Cup Tester but comes with a corrosion resisting insert in the cup for testing corrosive samples.
- Summary
-
Summary
-
It has been designed to carry out flash/no flash tests with a temperature range of 10°C to 130°C (50°F to 266°F) with no external cooling required. When connected to a suitable chilled water supply, the range is extended down to -20°C (-4°F).
There is also the Ramp Mode which increases the sample temperature at the rate of 2°C/min and automatically dips the ignitor every 1°C up to 100°C (every 2°C above 100°C), until either a flash is detected or the end of test temperature is reached.
- Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
- Flash/No Flash & Ramp Modes
- Electric ignitor
- Automatic dipping and flash detection
- ActiveCool electronic Peltier cooling
- 64 test memory & USB port
- Corrosion resisting insert
-
- Technical Information
-
Technical SpecificationElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
Part Number Description Certificate K6910M022 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) Temperature Range -30°C to 135°C (-22°F to 275°F) Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method Test Modes Rapid Equilibrium and Ramp Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes Test Duration Ramp Mode Typically 7 minutes Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes Cup Material Corrosion Resistant Steel Insert, Aluminium Cup Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”) Weight 8kg (17.6lb) Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting), 2ml (0.067fl oz) syringe, flash detector, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions ● Calibration Certificate supplied as standard.
-
- Standards
-
StandardsElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids
Standards in grey have been superseded but are still recognised in some industries.
-
- Downloads
-
- Part Numbers
-
Part NumbersElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)No data found!!
-
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) offers the same feature as the Active Cool Closed Cup Tester but comes with a corrosion resisting insert in the cup for testing corrosive samples.
- Part Number : K6910M022
- Certification : Calibration Certificate
- Accessories
-
AccessoriesElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
- Part NumberKT006910N009
- Home
- Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
- Industrial Finishing
The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) offers the same feature as the Active Cool Closed Cup Tester but comes with a corrosion resisting insert in the cup for testing corrosive samples.
Summary
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
It has been designed to carry out flash/no flash tests with a temperature range of 10°C to 130°C (50°F to 266°F) with no external cooling required. When connected to a suitable chilled water supply, the range is extended down to -20°C (-4°F).
There is also the Ramp Mode which increases the sample temperature at the rate of 2°C/min and automatically dips the ignitor every 1°C up to 100°C (every 2°C above 100°C), until either a flash is detected or the end of test temperature is reached.
- Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
- Flash/No Flash & Ramp Modes
- Electric ignitor
- Automatic dipping and flash detection
- ActiveCool electronic Peltier cooling
- 64 test memory & USB port
- Corrosion resisting insert
Technical SpecificationElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)Part Number Description Certificate K6910M022 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) Temperature Range -30°C to 135°C (-22°F to 275°F) Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method Test Modes Rapid Equilibrium and Ramp Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes Test Duration Ramp Mode Typically 7 minutes Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes Cup Material Corrosion Resistant Steel Insert, Aluminium Cup Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”) Weight 8kg (17.6lb) Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting), 2ml (0.067fl oz) syringe, flash detector, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions ● Calibration Certificate supplied as standard.StandardsElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids
Standards in grey have been superseded but are still recognised in some industries.
Part NumbersElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)No data found!!-
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)
The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting) offers the same feature as the Active Cool Closed Cup Tester but comes with a corrosion resisting insert in the cup for testing corrosive samples.
- Part Number : K6910M022
- Certification : Calibration Certificate
AccessoriesElcometer 6910 Setaflash ‘Series 8’ Active-Cool (Corrosion Resisting)- Part Number: KT006910N009
-
- Part Numbers
-