Elcometer 456 Coating Thickness Gauge Probe Range
- Protective Coatings
- Industrial Finishing


All Elcometer 456 Coating Thickness Gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.
- Summary
-
Summary
-
Ferrous Probes (F)
- Ferrous probes measure non-magnetic coatings on ferromagnetic substrates
- Elcometer 456 ferrous gauges accept any ferrous probe
Non-Ferrous Probes (N)
- Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates
- Elcometer 456 non-ferrous gauges accept any non-ferrous probe
Dual Probes (FNF)
- Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection
- Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes
High Temperature
- Elcometer probes have a maximum operating temperature of 80°C (176°F)*
- Separate ferrous probes have a maximum operating temperature of 150°C (300°F)*
- Hi-Temperature PINIP™ has a maximum operating temperature of 250°C (480°F)*
*The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.
Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.
Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.
-
- Key Features
-
Key Features
Elcometer 456 Coating Thickness Gauge Probe Range
Straight Probes
Standard Straight Probe
Standard probes measure coatings on both flat and curved surfaces.Anodising Probe
Chemical resistant & washable - ideal for the anodising environment.Mini Probe
Mini probes are ideal for harder to reach areas and edges.Waterproof Probe
Sealed for use underwater at depth, even in diving gloves.Soft Coating Probe
Large surface area probes are for soft materials (HVCA approved).Thick Coatings Probe
Ideal for measuring coatings up to 31mm thick.Scan Probes
Standard Scan Probe
Rapidly scan large surface areas without damaging the probe or the coating.Ball Bearing Scan Probe*
Clip on adaptors for large coated structures, abrasive coatings and pre-construction primers.Angled Probes
Right Angle Probe
Take readings in areas with restricted clearance.Mini Right Angle Probe
For measuring coatings on edges, narrow pipes or small surface areas.Telescopic Probe
Extending probes for hard to reach areas.45° Angle Probe
Measure difficult to access or complex areas.Plug In Integral Probes (PINIP™)
PINIP™ Integral Probe
Transforms a separate gauge into an integral gauge, ideal for single-handed use.Hi-Temperature PINIP™
Measure coatings on ferrous substrates up to 250°C (480°F).Armoured Cable Probes
F / FNF Armoured Probe
Reinforced heavy duty cables reduce the risk of cable damage.*UK Patent Number: 2571577
-
- Technical Information
-
Technical SpecificationElcometer 456 Coating Thickness Gauge Probe Range
Scale 0.5: Range : 0-500μm (0-20mils) Accuracya (±1-3% or ±0.1mil) Range 0-500μm (0-20mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3---A 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3R90A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3R45A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Straight Mini Probe
Probe Length: 150mm (5.90”)cT456CFM3---C 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CFM3R90C 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") 45° Angle Mini Probe
Probe Length: 300mm (11.80”)cT456CFM3R45D 18mm (0.71”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 300mm (11.80”)cT456CFM3R90D 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Non-Ferrous (N) Straight Mini Probe
Probe Length: 45mm (1.77”)cT456CNM3---A 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CNM3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Straight Mini Probe
Probe Length: 150mm (5.90”)cT456CNM3---C 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CNM3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 400mm (15.70”)cT456CNM3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Non-Ferrous - Graphite (N) Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CNMG3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CNMG3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 400mm (15.70”)cT456CNMG3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Scale 1: Range : 0-1500μm (0-60mils) Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil) Ranged 0-1500μm (0-60mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF1S 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") Straight Probe - sealed
Probe Length: 45mm (1.77”)cT456CF1E 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") Scan Probe
Probe Length: 45mm (1.77”)cT456CF1U 86mm (3.38”) 15mm (0.59”) Flat Surface Flat Surface Scan Probe - armoured
Probe Length: 45mm (1.77”)cT456CF1UARM 140mm (5.51”) 15mm (0.59”) Flat Surface Flat Surface 90° Probe
Probe Length: 45mm (1.77”)cT456CF1R 28mm (1.10”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") 90° Mini Probe
Probe Length: 45mm (1.77”)cT456CFM5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") 90° Mini Probe - sealed
Probe Length: 45mm (1.77”)cT456CFME5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") 90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)cT456CFME5R90A-2 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") PINIP™ Integral Probe T456CF1P 170mm (6.69”) 4mm (0.16”) 4mm (0.16") 60mm (2.36") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN1S 85mm (3.35”) 4mm (0.16”) 10mm (0.39") 10mm (0.39") 90° Probe
Probe Length: 45mm (1.77”)cT456CN1R 28mm (1.10”) 4mm (0.16”) 10mm (0.39") 14mm (0.55") Mini 90° Probe
Probe Length: 45mm (1.77”)cT456CNM5R90A 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Mini 90°Probe
Probe Length: 150mm (5.90”)cT456CNM5R90C 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Mini 90° Probe
Probe Length: 400mm (15.7”)cT456CNM5R90E 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Anodiser Probe
Probe Length: 45mm (1.77”)cT456CN1AS 100mm (3.94”) 4mm (0.16”) 10mm (0.39") 14mm (0.55") PINIP™ Integral Probe T456CN1P 180mm (7.09”) 4mm (0.16”) 10mm (0.39") 50mm (1.97") Ferrous & Non-Ferrous (FNF) Straight Probe
Probe Length: 45mm (1.77”)cT456CFNF1S 88mm (3.46”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CFNF1ARM 185mm (7.28") F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") Scan Probe
Probe Length: 45mm (1.77”)cT456CFNF1U 89mm (3.50”) 15mm (0.59”) Flat Surface Flat Surface Right Angle Probe
Probe Length: 45mm (1.77”)cT456CFNF1R 38mm (1.50”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") PINIP™ Integral Probe T456CFNF1P 180mm (7.09”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")65mm (2.56") Scale 2: Range : 0-5mm (0-200mils) Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil) Ranged 0-5mm (0-200mils) Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF2S 89mm (3.50”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Scan Probe
Probe Length: 45mm (1.77”)cT456CF2U 90mm (3.54”) 15mm (0.59”) Flat Surface Flat Surface 90° Probe
Probe Length: 45mm (1.77”)cT456CF2R 32mm (1.26”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CF2ARM 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Telescopic Probe
Probe Length: 56-122cm (22-48”)cT456CF2T 36mm (1.42”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Soft Coating Probe
Probe Length: 45mm (1.77”)cT456CF2B 89mm (3.50”) 8mm (0.32”) Flat Surface Flat Surface Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)cT456CF2SW 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-5 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-15 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-30 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-50 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-75 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") PINIP™ Integral Probe T456CF2P 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36") Hi-Temperature PINIP™ T456CF2PHT 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN2S 88mm (3.46”) 14mm (0.55”) 100mm (3.97") 150mm (5.90") PINIP™ Integral Probe T456CN2P 185mm (7.28") 14mm (0.55”) 100mm (3.97") 150mm (5.90") Scale 3: Range : 0-13mm (0-500mils) Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils) Ranged 0-13mm (0-500mils) Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF3S 102mm (4.02”) 14mm (0.55”) 15mm (0.59") 40mm (1.98") PINIP™ Integral Probe T456CF3P 184mm (7.24”) 14mm (0.55”) 15mm (0.59") 45mm (1.77") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN3S 170mm (6.69”) 35mm (1.38”) Flat Surface Flat Surface Scale FM7: Range: 0.60-3.8mm (25-150mils) Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils) Ranged 0.60-3.8mm (25-150mils) Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM7R45A 20mm (0.79”) 6.5 mm (0.26’’) - - Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF6S 150mm (5.90”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CF6ARM 190mm (7.48”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN6S 160mm (6.30”) 58mm (2.29”) Flat Surface Flat Surface Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CN6ARM 200mm (7.87") 58mm (2.29”) Flat Surface Flat Surface Scale 7: Range : 0-31mm (0-1220mils) Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged 0-31mm (0-1220mils) Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe armoured cable
Probe Length: 45mm (1.77”)cT456CF7ARM 200mm (7.87") 55 x 55mm2 (2.17 x 2.17 inch2) 40mm (1.58") 170mm (6.70") Scale 0.5: Range : 0-500μm (0-20mils) Accuracya (±1-3% or ±0.1mil) Range 0-500μm (0-20mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)Certificate Ferrous (F) Part Number T456CFM3---A Description Straight Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R45A Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3---C Description Straight Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R45D Description 45° Angle Mini Probe
Probe Length: 300mm (11.80”)cMinimum Headroom 18mm (0.71”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90D Description Right Angle Mini Probe
Probe Length: 300mm (11.80”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Non-Ferrous (N) Part Number T456CNM3---A Description Straight Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3---C Description Straight Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90E Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Non-Ferrous - Graphite (N) Part Number T456CNMG3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNMG3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNMG3R90E Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Scale 1: Range : 0-1500μm (0-60mils) Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil) Ranged 0-1500μm (0-60mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)Certificate Ferrous (F) Part Number T456CF1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF1E Description Straight Probe - sealed
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF1U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 86mm (3.38”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF1UARM Description Scan Probe - armoured
Probe Length: 45mm (1.77”)cMinimum Headroom 140mm (5.51”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF1R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 28mm (1.10”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CFM5R90A Description 90° Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFME5R90A Description 90° Mini Probe - sealed
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFME5R90A-2 Description 90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CF1P Description PINIP™ Integral Probe Minimum Headroom 170mm (6.69”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Non-Ferrous (N) Part Number T456CN1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 10mm (0.39") Part Number T456CN1R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 28mm (1.10”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 14mm (0.55") Part Number T456CNM5R90A Description Mini 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM5R90C Description Mini 90°Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM5R90E Description Mini 90° Probe
Probe Length: 400mm (15.7”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CN1AS Description Anodiser Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 100mm (3.94”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 14mm (0.55") Part Number T456CN1P Description PINIP™ Integral Probe Minimum Headroom 180mm (7.09”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 50mm (1.97") Ferrous & Non-Ferrous (FNF) Part Number T456CFNF1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 88mm (3.46”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 185mm (7.28") Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CFNF1R Description Right Angle Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 38mm (1.50”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1P Description PINIP™ Integral Probe Minimum Headroom 180mm (7.09”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 65mm (2.56") Scale 2: Range : 0-5mm (0-200mils) Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil) Ranged 0-5mm (0-200mils) Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)Certificate Ferrous (F) Part Number T456CF2S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 90mm (3.54”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF2R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 32mm (1.26”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2T Description Telescopic Probe
Probe Length: 56-122cm (22-48”)cMinimum Headroom 36mm (1.42”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2B Description Soft Coating Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF2SW Description Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-5 Description Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-15 Description Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-30 Description Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-50 Description Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-75 Description Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2P Description PINIP™ Integral Probe Minimum Headroom 174mm (6.85”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Part Number T456CF2PHT Description Hi-Temperature PINIP™ Minimum Headroom 174mm (6.85”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Non-Ferrous (N) Part Number T456CN2S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 88mm (3.46”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 100mm (3.97") Minimum Concave Surface Radius 150mm (5.90") Part Number T456CN2P Description PINIP™ Integral Probe Minimum Headroom 185mm (7.28") Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 100mm (3.97") Minimum Concave Surface Radius 150mm (5.90") Scale 3: Range : 0-13mm (0-500mils) Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils) Ranged 0-13mm (0-500mils) Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)Certificate Ferrous (F) Part Number T456CF3S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 102mm (4.02”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 15mm (0.59") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF3P Description PINIP™ Integral Probe Minimum Headroom 184mm (7.24”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 15mm (0.59") Minimum Concave Surface Radius 45mm (1.77") Non-Ferrous (N) Part Number T456CN3S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 170mm (6.69”) Minimum Sample Diameterb 35mm (1.38”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Scale FM7: Range : 0.60-3.8mm (25-150mils) Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils) Ranged 0.60-3.8mm (25-150mils) Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)Certificate Ferrous (F) Part Number T456CFM7R45A Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 20mm (0.79”) Minimum Sample Diameterb 6.5 mm (0.26’’) Minimum Convex Surface Diameter - Minimum Concave Surface Radius - Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)Certificate Ferrous (F) Part Number T456CF6S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 150mm (5.90”) Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 35mm (1.40") Minimum Concave Surface Radius 170mm (6.70") Part Number T456CF6ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 190mm (7.48”) Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 35mm (1.40") Minimum Concave Surface Radius 170mm (6.70") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN6S Minimum Headroom 160mm (6.30”) Minimum Sample Diameterb 58mm (2.29”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CN6ARM Minimum Headroom 200mm (7.87") Minimum Sample Diameterb 58mm (2.29”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Scale 7: Range : 0-31mm (0-1220mils) Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged 0-31mm (0-1220mils) Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)Certificate Ferrous (F) Part Number T456CF7ARM Description Straight Probe armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 200mm (7.87") Minimum Sample Diameterb 55 x 55mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 40mm (1.58") Minimum Concave Surface Radius 170mm (6.70") a. Whichever is the greater
b. FNF (F): FNF probe in F Mode / FNF (N): FNF probe in N
c. Probe length is measured from X to Y
d. Excluding Scan Probe end cap
e. Scan Probe accuracy is ±3% or ±0.02mm (0.8mil) with cap fitted, ±1-3% or ±0.02mm (0.8mil) without cap, when calibrated using a sample of the uncoated substrate
● Test Certificate supplied as standard.
Elcometer 456 Probes are covered by a one-year warranty
-
- Downloads
-
Downloads
- Part Numbers
-
Part NumbersElcometer 456 Coating Thickness Gauge Probe RangeNo data found!!
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 300mm (11.80”)
- Minimum Headroom: 18mm (0.71”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R45D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 300mm (11.80”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3---C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3---A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3---C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3---A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale FM7
- Substrate Probe: Ferrous (F) Probes
- Range: 0.60-3.8mm, 25-150mils
- Accuracy: ±7.5% or ±114μm, ±7,5% or ±4,5mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 20mm (0.79”)
- Minimum Sample Diameter: 6.5 mm (0.26’’)
- Part Number : T456CFM7R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 86mm (3.38”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe Armoured - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 140mm (5.51”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF1UARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 28mm (1.10”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFME5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed, 2m cable - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFME5R90A-2
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 170mm (6.69”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe sealed - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 28mm (1.10”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 180mm (7.09”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Anodiser Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 100mm (3.94”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1AS
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 88mm (3.46”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CFNF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 38mm (1.50”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 180mm (7.09”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 185mm (7.28")
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 90mm (3.54”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF2U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 32mm (1.26”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Telescopic Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 56-122cm (22-48”)
- Minimum Headroom: 36mm (1.42”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2T
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Soft Coating Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2B
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 1m (3’) cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 5m (15") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-5
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 15m (45") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-15
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 30m (98") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-30
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 50m (164") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-50
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 75m (250") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-75
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 174mm (6.85”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Hi-Temperature PINIP™ - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 174mm (6.85”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2PHT
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 88mm (3.46”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CN2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 185mm (7.28")
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CN2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 102mm (4.02”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CF3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 3
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Minimum Headroom: 184mm (7.24”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CF3P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 170mm (6.69”)
- Minimum Sample Diameter: 35mm (1.38”)
- Part Number : T456CN3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 150mm (5.90”)
- Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 190mm (7.48”)
- Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 160mm (6.30”)
- Minimum Sample Diameter: 58mm (2.29”)
- Part Number : T456CN6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 200mm (7.87")
- Minimum Sample Diameter: 58mm (2.29”)
- Part Number : T456CN6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 7
- Substrate Probe: Ferrous (F) Probes
- Range: 0-31mm, 0-1220mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 200mm (7.87")
- Minimum Sample Diameter: 55 x 55mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF7ARM
- Certification : Test Certificate
- Accessories
-
AccessoriesElcometer 456 Coating Thickness Gauge Probe Range
- Part NumberT9997766-
- Part NumberT99913225
- Part NumberT9997381-
- Part NumberT99913133
- Part NumberT456C23956
- Part NumberT456C29050
- Home
- Elcometer 456 Coating Thickness Gauge Probe Range
Elcometer 456 Coating Thickness Gauge Probe Range
- Protective Coatings
- Industrial Finishing
All Elcometer 456 Coating Thickness Gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.
Ferrous Probes (F)
- Ferrous probes measure non-magnetic coatings on ferromagnetic substrates
- Elcometer 456 ferrous gauges accept any ferrous probe
Non-Ferrous Probes (N)
- Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates
- Elcometer 456 non-ferrous gauges accept any non-ferrous probe
Dual Probes (FNF)
- Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection
- Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes
High Temperature
- Elcometer probes have a maximum operating temperature of 80°C (176°F)*
- Separate ferrous probes have a maximum operating temperature of 150°C (300°F)*
- Hi-Temperature PINIP™ has a maximum operating temperature of 250°C (480°F)*
*The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.
Summary
Elcometer 456 Coating Thickness Gauge Probe Range
Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.
Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.
Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.
Key Features
Elcometer 456 Coating Thickness Gauge Probe Range
Straight Probes
Standard Straight Probe
Standard probes measure coatings on both flat and curved surfaces.Anodising Probe
Chemical resistant & washable - ideal for the anodising environment.Mini Probe
Mini probes are ideal for harder to reach areas and edges.Waterproof Probe
Sealed for use underwater at depth, even in diving gloves.Soft Coating Probe
Large surface area probes are for soft materials (HVCA approved).Thick Coatings Probe
Ideal for measuring coatings up to 31mm thick.Scan Probes
Standard Scan Probe
Rapidly scan large surface areas without damaging the probe or the coating.Ball Bearing Scan Probe*
Clip on adaptors for large coated structures, abrasive coatings and pre-construction primers.Angled Probes
Right Angle Probe
Take readings in areas with restricted clearance.Mini Right Angle Probe
For measuring coatings on edges, narrow pipes or small surface areas.Telescopic Probe
Extending probes for hard to reach areas.45° Angle Probe
Measure difficult to access or complex areas.Plug In Integral Probes (PINIP™)
PINIP™ Integral Probe
Transforms a separate gauge into an integral gauge, ideal for single-handed use.Hi-Temperature PINIP™
Measure coatings on ferrous substrates up to 250°C (480°F).Armoured Cable Probes
F / FNF Armoured Probe
Reinforced heavy duty cables reduce the risk of cable damage.*UK Patent Number: 2571577
Technical SpecificationElcometer 456 Coating Thickness Gauge Probe RangeScale 0.5: Range : 0-500μm (0-20mils) Accuracya (±1-3% or ±0.1mil) Range 0-500μm (0-20mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3---A 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3R90A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM3R45A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Straight Mini Probe
Probe Length: 150mm (5.90”)cT456CFM3---C 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CFM3R90C 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") 45° Angle Mini Probe
Probe Length: 300mm (11.80”)cT456CFM3R45D 18mm (0.71”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Right Angle Mini Probe
Probe Length: 300mm (11.80”)cT456CFM3R90D 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26") Non-Ferrous (N) Straight Mini Probe
Probe Length: 45mm (1.77”)cT456CNM3---A 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CNM3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Straight Mini Probe
Probe Length: 150mm (5.90”)cT456CNM3---C 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CNM3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 400mm (15.70”)cT456CNM3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Non-Ferrous - Graphite (N) Right Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CNMG3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 150mm (5.90”)cT456CNMG3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Right Angle Mini Probe
Probe Length: 400mm (15.70”)cT456CNMG3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33") Scale 1: Range : 0-1500μm (0-60mils) Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil) Ranged 0-1500μm (0-60mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF1S 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") Straight Probe - sealed
Probe Length: 45mm (1.77”)cT456CF1E 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") Scan Probe
Probe Length: 45mm (1.77”)cT456CF1U 86mm (3.38”) 15mm (0.59”) Flat Surface Flat Surface Scan Probe - armoured
Probe Length: 45mm (1.77”)cT456CF1UARM 140mm (5.51”) 15mm (0.59”) Flat Surface Flat Surface 90° Probe
Probe Length: 45mm (1.77”)cT456CF1R 28mm (1.10”) 4mm (0.16”) 4mm (0.16") 25mm (0.98") 90° Mini Probe
Probe Length: 45mm (1.77”)cT456CFM5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") 90° Mini Probe - sealed
Probe Length: 45mm (1.77”)cT456CFME5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") 90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)cT456CFME5R90A-2 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26") PINIP™ Integral Probe T456CF1P 170mm (6.69”) 4mm (0.16”) 4mm (0.16") 60mm (2.36") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN1S 85mm (3.35”) 4mm (0.16”) 10mm (0.39") 10mm (0.39") 90° Probe
Probe Length: 45mm (1.77”)cT456CN1R 28mm (1.10”) 4mm (0.16”) 10mm (0.39") 14mm (0.55") Mini 90° Probe
Probe Length: 45mm (1.77”)cT456CNM5R90A 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Mini 90°Probe
Probe Length: 150mm (5.90”)cT456CNM5R90C 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Mini 90° Probe
Probe Length: 400mm (15.7”)cT456CNM5R90E 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33") Anodiser Probe
Probe Length: 45mm (1.77”)cT456CN1AS 100mm (3.94”) 4mm (0.16”) 10mm (0.39") 14mm (0.55") PINIP™ Integral Probe T456CN1P 180mm (7.09”) 4mm (0.16”) 10mm (0.39") 50mm (1.97") Ferrous & Non-Ferrous (FNF) Straight Probe
Probe Length: 45mm (1.77”)cT456CFNF1S 88mm (3.46”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CFNF1ARM 185mm (7.28") F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") Scan Probe
Probe Length: 45mm (1.77”)cT456CFNF1U 89mm (3.50”) 15mm (0.59”) Flat Surface Flat Surface Right Angle Probe
Probe Length: 45mm (1.77”)cT456CFNF1R 38mm (1.50”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")12.5mm (0.49") PINIP™ Integral Probe T456CFNF1P 180mm (7.09”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")65mm (2.56") Scale 2: Range : 0-5mm (0-200mils) Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil) Ranged 0-5mm (0-200mils) Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF2S 89mm (3.50”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Scan Probe
Probe Length: 45mm (1.77”)cT456CF2U 90mm (3.54”) 15mm (0.59”) Flat Surface Flat Surface 90° Probe
Probe Length: 45mm (1.77”)cT456CF2R 32mm (1.26”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CF2ARM 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Telescopic Probe
Probe Length: 56-122cm (22-48”)cT456CF2T 36mm (1.42”) 8mm (0.32”) 4mm (0.16") 25mm (0.98") Soft Coating Probe
Probe Length: 45mm (1.77”)cT456CF2B 89mm (3.50”) 8mm (0.32”) Flat Surface Flat Surface Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)cT456CF2SW 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-5 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-15 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-30 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-50 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)cT456CF2SW-75 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98") PINIP™ Integral Probe T456CF2P 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36") Hi-Temperature PINIP™ T456CF2PHT 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN2S 88mm (3.46”) 14mm (0.55”) 100mm (3.97") 150mm (5.90") PINIP™ Integral Probe T456CN2P 185mm (7.28") 14mm (0.55”) 100mm (3.97") 150mm (5.90") Scale 3: Range : 0-13mm (0-500mils) Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils) Ranged 0-13mm (0-500mils) Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF3S 102mm (4.02”) 14mm (0.55”) 15mm (0.59") 40mm (1.98") PINIP™ Integral Probe T456CF3P 184mm (7.24”) 14mm (0.55”) 15mm (0.59") 45mm (1.77") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN3S 170mm (6.69”) 35mm (1.38”) Flat Surface Flat Surface Scale FM7: Range: 0.60-3.8mm (25-150mils) Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils) Ranged 0.60-3.8mm (25-150mils) Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cT456CFM7R45A 20mm (0.79”) 6.5 mm (0.26’’) - - Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe
Probe Length: 45mm (1.77”)cT456CF6S 150mm (5.90”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70") Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CF6ARM 190mm (7.48”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN6S 160mm (6.30”) 58mm (2.29”) Flat Surface Flat Surface Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CN6ARM 200mm (7.87") 58mm (2.29”) Flat Surface Flat Surface Scale 7: Range : 0-31mm (0-1220mils) Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged 0-31mm (0-1220mils) Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)Certificate Description Part Number Minimum Headroom Minimum Sample Diameterb Minimum Convex Surface Diameter Minimum Concave Surface Radius Ferrous (F) Straight Probe armoured cable
Probe Length: 45mm (1.77”)cT456CF7ARM 200mm (7.87") 55 x 55mm2 (2.17 x 2.17 inch2) 40mm (1.58") 170mm (6.70") Scale 0.5: Range : 0-500μm (0-20mils) Accuracya (±1-3% or ±0.1mil) Range 0-500μm (0-20mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)Certificate Ferrous (F) Part Number T456CFM3---A Description Straight Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R45A Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3---C Description Straight Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R45D Description 45° Angle Mini Probe
Probe Length: 300mm (11.80”)cMinimum Headroom 18mm (0.71”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFM3R90D Description Right Angle Mini Probe
Probe Length: 300mm (11.80”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 3mm (0.12”) Minimum Convex Surface Diameter 1.9mm (0.07") Minimum Concave Surface Radius 6.5mm (0.26") Non-Ferrous (N) Part Number T456CNM3---A Description Straight Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3---C Description Straight Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 6mm (0.24”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM3R90E Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Non-Ferrous - Graphite (N) Part Number T456CNMG3R90A Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNMG3R90C Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNMG3R90E Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 6mm (0.24") Minimum Concave Surface Radius 8.5mm (0.33") Scale 1: Range : 0-1500μm (0-60mils) Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil) Ranged 0-1500μm (0-60mils) Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)Certificate Ferrous (F) Part Number T456CF1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF1E Description Straight Probe - sealed
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF1U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 86mm (3.38”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF1UARM Description Scan Probe - armoured
Probe Length: 45mm (1.77”)cMinimum Headroom 140mm (5.51”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF1R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 28mm (1.10”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CFM5R90A Description 90° Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFME5R90A Description 90° Mini Probe - sealed
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CFME5R90A-2 Description 90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 3mm (0.12") Minimum Concave Surface Radius 6.5mm (0.26") Part Number T456CF1P Description PINIP™ Integral Probe Minimum Headroom 170mm (6.69”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Non-Ferrous (N) Part Number T456CN1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 10mm (0.39") Part Number T456CN1R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 28mm (1.10”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 14mm (0.55") Part Number T456CNM5R90A Description Mini 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM5R90C Description Mini 90°Probe
Probe Length: 150mm (5.90”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CNM5R90E Description Mini 90° Probe
Probe Length: 400mm (15.7”)cMinimum Headroom 16mm (0.63”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 8.5mm (0.33") Part Number T456CN1AS Description Anodiser Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 100mm (3.94”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 14mm (0.55") Part Number T456CN1P Description PINIP™ Integral Probe Minimum Headroom 180mm (7.09”) Minimum Sample Diameterb 4mm (0.16”) Minimum Convex Surface Diameter 10mm (0.39") Minimum Concave Surface Radius 50mm (1.97") Ferrous & Non-Ferrous (FNF) Part Number T456CFNF1S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 88mm (3.46”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 185mm (7.28") Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CFNF1R Description Right Angle Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 38mm (1.50”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 12.5mm (0.49") Part Number T456CFNF1P Description PINIP™ Integral Probe Minimum Headroom 180mm (7.09”) Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”) Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")Minimum Concave Surface Radius 65mm (2.56") Scale 2: Range : 0-5mm (0-200mils) Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil) Ranged 0-5mm (0-200mils) Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)Certificate Ferrous (F) Part Number T456CF2S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2U Description Scan Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 90mm (3.54”) Minimum Sample Diameterb 15mm (0.59”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF2R Description 90° Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 32mm (1.26”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2T Description Telescopic Probe
Probe Length: 56-122cm (22-48”)cMinimum Headroom 36mm (1.42”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 25mm (0.98") Part Number T456CF2B Description Soft Coating Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 89mm (3.50”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Part Number T456CF2SW Description Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-5 Description Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-15 Description Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-30 Description Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-50 Description Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2SW-75 Description Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)cMinimum Headroom 138mm (5.43”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF2P Description PINIP™ Integral Probe Minimum Headroom 174mm (6.85”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Part Number T456CF2PHT Description Hi-Temperature PINIP™ Minimum Headroom 174mm (6.85”) Minimum Sample Diameterb 8mm (0.32”) Minimum Convex Surface Diameter 4mm (0.16") Minimum Concave Surface Radius 60mm (2.36") Non-Ferrous (N) Part Number T456CN2S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 88mm (3.46”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 100mm (3.97") Minimum Concave Surface Radius 150mm (5.90") Part Number T456CN2P Description PINIP™ Integral Probe Minimum Headroom 185mm (7.28") Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 100mm (3.97") Minimum Concave Surface Radius 150mm (5.90") Scale 3: Range : 0-13mm (0-500mils) Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils) Ranged 0-13mm (0-500mils) Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)Certificate Ferrous (F) Part Number T456CF3S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 102mm (4.02”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 15mm (0.59") Minimum Concave Surface Radius 40mm (1.98") Part Number T456CF3P Description PINIP™ Integral Probe Minimum Headroom 184mm (7.24”) Minimum Sample Diameterb 14mm (0.55”) Minimum Convex Surface Diameter 15mm (0.59") Minimum Concave Surface Radius 45mm (1.77") Non-Ferrous (N) Part Number T456CN3S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 170mm (6.69”) Minimum Sample Diameterb 35mm (1.38”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Scale FM7: Range : 0.60-3.8mm (25-150mils) Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils) Ranged 0.60-3.8mm (25-150mils) Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)Certificate Ferrous (F) Part Number T456CFM7R45A Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 20mm (0.79”) Minimum Sample Diameterb 6.5 mm (0.26’’) Minimum Convex Surface Diameter - Minimum Concave Surface Radius - Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)Certificate Ferrous (F) Part Number T456CF6S Description Straight Probe
Probe Length: 45mm (1.77”)cMinimum Headroom 150mm (5.90”) Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 35mm (1.40") Minimum Concave Surface Radius 170mm (6.70") Part Number T456CF6ARM Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 190mm (7.48”) Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 35mm (1.40") Minimum Concave Surface Radius 170mm (6.70") Non-Ferrous (N) Straight Probe
Probe Length: 45mm (1.77”)cT456CN6S Minimum Headroom 160mm (6.30”) Minimum Sample Diameterb 58mm (2.29”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Straight Probe - armoured cable
Probe Length: 45mm (1.77”)cT456CN6ARM Minimum Headroom 200mm (7.87") Minimum Sample Diameterb 58mm (2.29”) Minimum Convex Surface Diameter Flat Surface Minimum Concave Surface Radius Flat Surface Scale 7: Range : 0-31mm (0-1220mils) Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils) Ranged 0-31mm (0-1220mils) Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)Certificate Ferrous (F) Part Number T456CF7ARM Description Straight Probe armoured cable
Probe Length: 45mm (1.77”)cMinimum Headroom 200mm (7.87") Minimum Sample Diameterb 55 x 55mm2 (2.17 x 2.17 inch2) Minimum Convex Surface Diameter 40mm (1.58") Minimum Concave Surface Radius 170mm (6.70") a. Whichever is the greater
b. FNF (F): FNF probe in F Mode / FNF (N): FNF probe in N
c. Probe length is measured from X to Y
d. Excluding Scan Probe end cap
e. Scan Probe accuracy is ±3% or ±0.02mm (0.8mil) with cap fitted, ±1-3% or ±0.02mm (0.8mil) without cap, when calibrated using a sample of the uncoated substrate
● Test Certificate supplied as standard.
Elcometer 456 Probes are covered by a one-year warranty
Part NumbersElcometer 456 Coating Thickness Gauge Probe RangeNo data found!!-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 300mm (11.80”)
- Minimum Headroom: 18mm (0.71”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R45D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 300mm (11.80”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90D
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3---C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Ferrous (F) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 3mm (0.12”)
- Part Number : T456CFM3---A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3---C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 6mm (0.24”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM3---A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
- Substrate Probe: Non-Ferrous - Graphite (N)
- Range: 0-500μm, 0-20mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNMG3R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale FM7
- Substrate Probe: Ferrous (F) Probes
- Range: 0.60-3.8mm, 25-150mils
- Accuracy: ±7.5% or ±114μm, ±7,5% or ±4,5mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 20mm (0.79”)
- Minimum Sample Diameter: 6.5 mm (0.26’’)
- Part Number : T456CFM7R45A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 86mm (3.38”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe Armoured - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 140mm (5.51”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF1UARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 28mm (1.10”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFME5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed, 2m cable - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CFME5R90A-2
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 170mm (6.69”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe sealed - Scale 1
- Substrate Probe: Ferrous (F) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 85mm (3.35”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CF1E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 28mm (1.10”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90A
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 150mm (5.90”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90C
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 400mm (15.70”)
- Minimum Headroom: 16mm (0.63”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CNM5R90E
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 180mm (7.09”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Anodiser Probe - Scale 1
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 100mm (3.94”)
- Minimum Sample Diameter: 4mm (0.16”)
- Part Number : T456CN1AS
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 88mm (3.46”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CFNF1U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Right Angle Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 38mm (1.50”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Minimum Headroom: 180mm (7.09”)
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 1
- Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
- Range: 0-1,500μm, 0-60mils
- Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 185mm (7.28")
- Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
- Part Number : T456CFNF1ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 90mm (3.54”)
- Minimum Sample Diameter: 15mm (0.59”)
- Part Number : T456CF2U
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 32mm (1.26”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2R
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Telescopic Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 56-122cm (22-48”)
- Minimum Headroom: 36mm (1.42”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2T
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Soft Coating Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 89mm (3.50”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2B
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 1m (3’) cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 5m (15") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-5
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 15m (45") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-15
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 30m (98") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-30
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 50m (164") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-50
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Waterproof Probe 75m (250") cable - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 138mm (5.43”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2SW-75
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 174mm (6.85”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Hi-Temperature PINIP™ - Scale 2
- Substrate Probe: Ferrous (F) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 174mm (6.85”)
- Minimum Sample Diameter: 8mm (0.32”)
- Part Number : T456CF2PHT
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 88mm (3.46”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CN2S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-5mm, 0-200mils
- Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
- Minimum Headroom: 185mm (7.28")
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CN2P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 102mm (4.02”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CF3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 3
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Minimum Headroom: 184mm (7.24”)
- Minimum Sample Diameter: 14mm (0.55”)
- Part Number : T456CF3P
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils
- Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 170mm (6.69”)
- Minimum Sample Diameter: 35mm (1.38”)
- Part Number : T456CN3S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 150mm (5.90”)
- Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
- Substrate Probe: Ferrous (F) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 190mm (7.48”)
- Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 160mm (6.30”)
- Minimum Sample Diameter: 58mm (2.29”)
- Part Number : T456CN6S
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
- Substrate Probe: Non-Ferrous (N) Probes
- Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 200mm (7.87")
- Minimum Sample Diameter: 58mm (2.29”)
- Part Number : T456CN6ARM
- Certification : Test Certificate
-
Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 7
- Substrate Probe: Ferrous (F) Probes
- Range: 0-31mm, 0-1220mils
- Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
- Probe Length: 45mm (1.77”)
- Minimum Headroom: 200mm (7.87")
- Minimum Sample Diameter: 55 x 55mm2 (2.17 x 2.17 inch2)
- Part Number : T456CF7ARM
- Certification : Test Certificate
AccessoriesElcometer 456 Coating Thickness Gauge Probe Range- Part Number: T9997766-
- Part Number: T99913225
- Part Number: T9997381-
- Part Number: T99913133
- Part Number: T456C23956
- Part Number: T456C29050
- Part Numbers
-