Elcometer 355 Precision Coating Thickness Gauge Probe Range
- Industrial Finishing


Unique probe modules allow the Elcometer 355 Coating Thickness Gauge to be versatile and flexible for any coating thickness measurement application.
- Summary
-
Summary
-
Probe modules can be freely interchanged as required for both ferrous (F) and non-ferrous (N) metal substrates.
Most coating thickness gauge probes are capable of an accuracy of ±1% of the reading on a variety of coatings and surfaces.
Telescopic probes extend from 410mm (16”) to 1100mm (43”).
-
- Technical Information
-
Technical SpecificationElcometer 355 Precision Coating Thickness Gauge Probe Range
Scale 1 Range 0-1,500μm Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate F1 Standard T35511952 85mm (3.35”) 6mm (0.24")
N1 Standard T35511982 85mm (3.35”) 8mm (0.31”)
Scale 4 Range 0-250μm (0-10mils) Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils) Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate F4 Standard T35511950 85mm (3.35”) 4mm (0.16”)
N4 Standard T35511980 90mm (3.54”) 8mm (0.32”)
Scale 1 Range 0-1,500μm Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)Part Number Certificate T35511952
Probe Design F1 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 6mm (0.24") T35511982
Probe Design N1 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 8mm (0.31”) Scale 4 Range 0-250μm (0-10mils) Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils) Part Number Certificate T35511950
Probe Design F4 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) T35511980
Probe Design N4 Standard Minimum Headroom 90mm (3.54”) Minimum Sample Diameterb 8mm (0.32”) * Whichever is greater
● Test Certificate supplied as standard.
-
- Downloads
-
Downloads
- Part Numbers
-
Part NumbersElcometer 355 Precision Coating Thickness Gauge Probe RangeNo data found!!
-
Elcometer 355 Precision Coating Thickness Gauge F1 Standard - Scale 1- Range: 0-1,500μm
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511952
-
Elcometer 355 Precision Coating Thickness Gauge N1 Standard - Scale 1- Range: 0-1,500μm
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511982
-
Elcometer 355 Precision Coating Thickness Gauge F4 Standard - Scale 4- Range: 0-250μm (0-10mils)
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511950
-
Elcometer 355 Precision Coating Thickness Gauge N4 Standard - Scale 4- Range: 0-250μm (0-10mils)
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 90mm (3.54”)
- Part Number : T35511980
- Accessories
-
AccessoriesElcometer 355 Precision Coating Thickness Gauge Probe Range
Part Number: T95012880
Part Number: T95013028
Part Number: T95012888
Part Number: T9997766-
Part Number: T9997381-
Part Number: T95015589
- Home
- Elcometer 355 Precision Coating Thickness Gauge Probe Range
Elcometer 355 Precision Coating Thickness Gauge Probe Range
- Industrial Finishing


Unique probe modules allow the Elcometer 355 Coating Thickness Gauge to be versatile and flexible for any coating thickness measurement application.
Summary
Elcometer 355 Precision Coating Thickness Gauge Probe Range
Probe modules can be freely interchanged as required for both ferrous (F) and non-ferrous (N) metal substrates.
Most coating thickness gauge probes are capable of an accuracy of ±1% of the reading on a variety of coatings and surfaces.
Telescopic probes extend from 410mm (16”) to 1100mm (43”).
Technical SpecificationElcometer 355 Precision Coating Thickness Gauge Probe RangeScale 1 Range 0-1,500μm Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate F1 Standard T35511952 85mm (3.35”) 6mm (0.24")
N1 Standard T35511982 85mm (3.35”) 8mm (0.31”)
Scale 4 Range 0-250μm (0-10mils) Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils) Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate F4 Standard T35511950 85mm (3.35”) 4mm (0.16”)
N4 Standard T35511980 90mm (3.54”) 8mm (0.32”)
Scale 1 Range 0-1,500μm Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)Part Number Certificate T35511952
Probe Design F1 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 6mm (0.24") T35511982
Probe Design N1 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 8mm (0.31”) Scale 4 Range 0-250μm (0-10mils) Accuracy ±1% or ±1μm (±0.04mil)* Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils) Part Number Certificate T35511950
Probe Design F4 Standard Minimum Headroom 85mm (3.35”) Minimum Sample Diameterb 4mm (0.16”) T35511980
Probe Design N4 Standard Minimum Headroom 90mm (3.54”) Minimum Sample Diameterb 8mm (0.32”) * Whichever is greater
● Test Certificate supplied as standard. Part NumbersElcometer 355 Precision Coating Thickness Gauge Probe RangeNo data found!!-
Elcometer 355 Precision Coating Thickness Gauge F1 Standard - Scale 1- Range: 0-1,500μm
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511952
-
Elcometer 355 Precision Coating Thickness Gauge N1 Standard - Scale 1- Range: 0-1,500μm
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511982
-
Elcometer 355 Precision Coating Thickness Gauge F4 Standard - Scale 4- Range: 0-250μm (0-10mils)
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 85mm (3.35”)
- Part Number : T35511950
-
Elcometer 355 Precision Coating Thickness Gauge N4 Standard - Scale 4- Range: 0-250μm (0-10mils)
- Accuracy: ±1% or ±1μm (±0.04mil)*
- Minimum Headroom: 90mm (3.54”)
- Part Number : T35511980
AccessoriesElcometer 355 Precision Coating Thickness Gauge Probe Range
Part Number: T95012880
Part Number: T95013028
Part Number: T95012888
Part Number: T9997766-
Part Number: T9997381-
Part Number: T95015589
- Part Numbers
-