Elcometer 355 Precision Coating Thickness Gauge Probe Range

  • Industrial Finishing
Elcometer-355-Probe-intro
Elcometer-355-Probe-Range-intro

Unique probe modules allow the Elcometer 355 Coating Thickness Gauge to be versatile and flexible for any coating thickness measurement application.

  • Summary
    • Summary

    • Probe modules can be freely interchanged as required for both ferrous (F) and non-ferrous (N) metal substrates.

      Most coating thickness gauge probes are capable of an accuracy of ±1% of the reading on a variety of coatings and surfaces.

      Telescopic probes extend from 410mm (16”) to 1100mm (43”).

  • Technical Information
    • Technical Specification
      Elcometer 355 Precision Coating Thickness Gauge Probe Range
      Scale 1
      Range 0-1,500μm
      Accuracy ±1% or ±1μm (±0.04mil)*
      Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
      (0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)
      Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate
      F1 Standard T35511952 85mm (3.35”) 6mm (0.24")
      Test Certificate supplied as standard
      N1 Standard T35511982 85mm (3.35”) 8mm (0.31”)
      Test Certificate supplied as standard
      Scale 4
      Range 0-250μm (0-10mils)
      Accuracy ±1% or ±1μm (±0.04mil)*
      Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils)
      Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate
      F4 Standard T35511950 85mm (3.35”) 4mm (0.16”)
      Test Certificate supplied as standard
      N4 Standard T35511980 90mm (3.54”) 8mm (0.32”)
      Test Certificate supplied as standard
      Scale 1
      Range 0-1,500μm
      Accuracy ±1% or ±1μm (±0.04mil)*
      Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
      (0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)
      Part Number Certificate
      T35511952
      Test Certificate supplied as standard
      Probe Design F1 Standard
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 6mm (0.24")
      T35511982
      Test Certificate supplied as standard
      Probe Design N1 Standard
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 8mm (0.31”)
      Scale 4
      Range 0-250μm (0-10mils)
      Accuracy ±1% or ±1μm (±0.04mil)*
      Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils)
      Part Number Certificate
      T35511950
      Test Certificate supplied as standard
      Probe Design F4 Standard
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 4mm (0.16”)
      T35511980
      Test Certificate supplied as standard
      Probe Design N4 Standard
      Minimum Headroom 90mm (3.54”)
      Minimum Sample Diameterb 8mm (0.32”)
      * Whichever is greater
      ● Test Certificate supplied as standard.
  • Downloads
    • Downloads
        • Elcometer 355 Coating Thickness Gauge Instruction Manual

        • Elcometer 355 Coating Thickness Gauge Datasheet

  • Part Numbers
    • Part Numbers
      Elcometer 355 Precision Coating Thickness Gauge Probe Range
      • Elcometer 355 Precision Coating Thickness Gauge F1 Standard - Scale 1
        • Range: 0-1,500μm
        • Accuracy: ±1% or ±1μm (±0.04mil)*
        • Minimum Headroom: 85mm (3.35”)
        • Part Number : T35511952
      • Elcometer 355 Precision Coating Thickness Gauge N1 Standard - Scale 1
        • Range: 0-1,500μm
        • Accuracy: ±1% or ±1μm (±0.04mil)*
        • Minimum Headroom: 85mm (3.35”)
        • Part Number : T35511982
      • Elcometer 355 Precision Coating Thickness Gauge F4 Standard - Scale 4
        • Range: 0-250μm (0-10mils)
        • Accuracy: ±1% or ±1μm (±0.04mil)*
        • Minimum Headroom: 85mm (3.35”)
        • Part Number : T35511950
      • Elcometer 355 Precision Coating Thickness Gauge N4 Standard - Scale 4
        • Range: 0-250μm (0-10mils)
        • Accuracy: ±1% or ±1μm (±0.04mil)*
        • Minimum Headroom: 90mm (3.54”)
        • Part Number : T35511980
  • Accessories
    • Accessories
      Elcometer 355 Precision Coating Thickness Gauge Probe Range
      • Part Number: T95012880
      • Part Number: T95013028
      • Part Number: T95012888
      • Part Number: T9997766-
      • Part Number: T9997381-
      • Part Number: T95015589

Elcometer 355 Precision Coating Thickness Gauge Probe Range

  • Industrial Finishing
Elcometer-355-Probe-intro
Elcometer-355-Probe-Range-intro

Unique probe modules allow the Elcometer 355 Coating Thickness Gauge to be versatile and flexible for any coating thickness measurement application.

Summary

Elcometer 355 Precision Coating Thickness Gauge Probe Range

Probe modules can be freely interchanged as required for both ferrous (F) and non-ferrous (N) metal substrates.

Most coating thickness gauge probes are capable of an accuracy of ±1% of the reading on a variety of coatings and surfaces.

Telescopic probes extend from 410mm (16”) to 1100mm (43”).

Downloads
    • Elcometer 355 Coating Thickness Gauge Instruction Manual

    • Elcometer 355 Coating Thickness Gauge Datasheet

Technical Specification
Elcometer 355 Precision Coating Thickness Gauge Probe Range
Scale 1
Range 0-1,500μm
Accuracy ±1% or ±1μm (±0.04mil)*
Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)
Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate
F1 Standard T35511952 85mm (3.35”) 6mm (0.24")
Test Certificate supplied as standard
N1 Standard T35511982 85mm (3.35”) 8mm (0.31”)
Test Certificate supplied as standard
Scale 4
Range 0-250μm (0-10mils)
Accuracy ±1% or ±1μm (±0.04mil)*
Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils)
Probe Design Part Number Minimum Headroom Minimum Sample Diameterb Certificate
F4 Standard T35511950 85mm (3.35”) 4mm (0.16”)
Test Certificate supplied as standard
N4 Standard T35511980 90mm (3.54”) 8mm (0.32”)
Test Certificate supplied as standard
Scale 1
Range 0-1,500μm
Accuracy ±1% or ±1μm (±0.04mil)*
Resolution 0.1μm: 0-200μm; 0.5μm: 200-500μm; 1μm: 500-1,500μm
(0.005mil: 0-8mils; 0.02mil: 8-20mils; 0.05mil: 20-60mils)
Part Number Certificate
T35511952
Test Certificate supplied as standard
Probe Design F1 Standard
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 6mm (0.24")
T35511982
Test Certificate supplied as standard
Probe Design N1 Standard
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 8mm (0.31”)
Scale 4
Range 0-250μm (0-10mils)
Accuracy ±1% or ±1μm (±0.04mil)*
Resolution 0.1μm: 0-250μm (0.005mil: 0-10mils)
Part Number Certificate
T35511950
Test Certificate supplied as standard
Probe Design F4 Standard
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 4mm (0.16”)
T35511980
Test Certificate supplied as standard
Probe Design N4 Standard
Minimum Headroom 90mm (3.54”)
Minimum Sample Diameterb 8mm (0.32”)
* Whichever is greater
● Test Certificate supplied as standard.
Part Numbers
Elcometer 355 Precision Coating Thickness Gauge Probe Range
  • Elcometer 355 Precision Coating Thickness Gauge F1 Standard - Scale 1
    • Range: 0-1,500μm
    • Accuracy: ±1% or ±1μm (±0.04mil)*
    • Minimum Headroom: 85mm (3.35”)
    • Part Number : T35511952
  • Elcometer 355 Precision Coating Thickness Gauge N1 Standard - Scale 1
    • Range: 0-1,500μm
    • Accuracy: ±1% or ±1μm (±0.04mil)*
    • Minimum Headroom: 85mm (3.35”)
    • Part Number : T35511982
  • Elcometer 355 Precision Coating Thickness Gauge F4 Standard - Scale 4
    • Range: 0-250μm (0-10mils)
    • Accuracy: ±1% or ±1μm (±0.04mil)*
    • Minimum Headroom: 85mm (3.35”)
    • Part Number : T35511950
  • Elcometer 355 Precision Coating Thickness Gauge N4 Standard - Scale 4
    • Range: 0-250μm (0-10mils)
    • Accuracy: ±1% or ±1μm (±0.04mil)*
    • Minimum Headroom: 90mm (3.54”)
    • Part Number : T35511980
   
Accessories
Elcometer 355 Precision Coating Thickness Gauge Probe Range
  • Part Number: T95012880
  • Part Number: T95013028
  • Part Number: T95012888
  • Part Number: T9997766-
  • Part Number: T9997381-
  • Part Number: T95015589