Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
- Industrial Finishing

The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester offers the same features as the Setaflash ‘Series 8’ Closed Cup Tester but is designed with a temperature range of -30°C to 135°C (-22°F to 275°F) with no external cooling required.
- Summary
-
Summary
-
This Active Cool Closed Cup Tester uses the Peltier cell technology for heating and cooling, ensuring precise temperature control and rapid cool down after a test is completed.
When connected to a suitable water supply, the temperature range is extended down to -20°C (- 4°F) and operates with an electric ignition.
- Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
- Flash/No Flash & Ramp Modes
- Electric ignitor
- Automatic dipping and flash detection
- Active-Cool electronic Peltier cooling
- 64 test memory & USB port
-
- Technical Information
-
Technical SpecificationElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
Part Number Description Certificate K6910M021 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester Temperature Range -30°C to 135°C (-22°F to 275°F) Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method Test Modes Rapid Equilibrium and Ramp Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes Test Duration Ramp Mode Typically 7 minutes Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes Cup Material Aluminium Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”) Weight 8kg (17.6lb) Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester, 2ml (0.067fl oz) syringe, ignitor, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions ● Calibration Certificate supplied as standard.
-
- Standards
-
StandardsElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
ASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids
Standards in grey have been superseded but are still recognised in some industries.
-
- Downloads
-
- Part Numbers
-
Part NumbersElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup TesterNo data found!!
-
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
- Part Number : K6910M021
- Accessories
-
AccessoriesElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
- Part Number: KT006910N009
-
- Home
- Coatings Inspection
- Flash Point
- Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
- Industrial Finishing
The Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester offers the same features as the Setaflash ‘Series 8’ Closed Cup Tester but is designed with a temperature range of -30°C to 135°C (-22°F to 275°F) with no external cooling required.
Summary
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
This Active Cool Closed Cup Tester uses the Peltier cell technology for heating and cooling, ensuring precise temperature control and rapid cool down after a test is completed.
When connected to a suitable water supply, the temperature range is extended down to -20°C (- 4°F) and operates with an electric ignition.
- Small sample size, 2ml (0.067fl oz) or 4ml (0.135fl oz)
- Flash/No Flash & Ramp Modes
- Electric ignitor
- Automatic dipping and flash detection
- Active-Cool electronic Peltier cooling
- 64 test memory & USB port
Technical SpecificationElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup TesterPart Number Description Certificate K6910M021 Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester Temperature Range -30°C to 135°C (-22°F to 275°F) Sample Size 2ml (0.067fl oz) or 4ml (0.135fl oz) according to method Test Modes Rapid Equilibrium and Ramp Test Duration Rapid Equilibrium Mode 1 minute below 100°C (212°F), 2 minutes above 100°C (212°F), FAME 1 minute or user defined 1 to 99 minutes Test Duration Ramp Mode Typically 7 minutes Cool Down Time 80°C to 20°C (176°F to 68°F) in 4 minutes Cup Material Aluminium Dimensions 300 x 340 x 380mm (11.8 x 13.4 x 15.0”) Weight 8kg (17.6lb) Packing List Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester, 2ml (0.067fl oz) syringe, ignitor, mains power cable, programming plug, 2mm Allen key, 2.5mm Allen key, certified flash point material (50ml/1.7fl oz), certificate of calibration, warranty registration form and operating instructions ● Calibration Certificate supplied as standard.StandardsElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup TesterASTM D3278, ASTM D3828, ASTM D7236, ASTM E502, BS 2000-523, CLP Regulations EC No 1272/2008, EPA 1020 A & B, ISO 3679, ISO 3680, UN Class 3 Non-viscous Flammable Liquids
Standards in grey have been superseded but are still recognised in some industries.
Part NumbersElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup TesterNo data found!!-
Elcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester
- Part Number : K6910M021
AccessoriesElcometer 6910 Setaflash ‘Series 8’ Active-Cool Closed Cup Tester- Part Number: KT006910N009
- Part Numbers
-