Users can either place a sample on the meter’s flat sensor or immerse the meter’s sensor directly into the solution under test. The Elcometer 138 can be used for a broad range of applications, including: soluble salt concentrations, the electric conductivity (EC) of solutions used in agricultural operations and measuring rainwater pollution levels.
The Elcometer 138 Conductivity Meter includes a convenient salinity conversion indicator.
Features:
- Highly precise measurements can be obtained from a single drop
- Automatic range switching gives a wide measurement range of 1μS/cm to 19.99mS/cm
- Out of range and low battery alarms
- Visual indication when ambient temperature is outside the operating range
-
- Technical Information
-
Technical SpecificationElcometer 138 Conductivity Meter
Part Number Description E138-CM Elcometer 138 Conductivity Meter Measurement Principle Measurement Principle Measurement Mode Conductivity, Temperature Minimum Sample Volume 0.12ml Measuring Range 0 - 19.99mS/cm Resolution 0 - 1999μS/cm: 1μS/cm
2.00 - 19.99mS/cm: 0.01mS/cmAccuracy ±2% full scale (for each range) Operating Temperature 5°C to 40°C (41°F to 104°F) Operating Humidity 85% or less relative humidity (no condensation) Battery Type 2 x CR2032 lithium batteries Battery Life approx. 200 hours of continuous use without backlight Weight 50g (1.76oz) - including sensor and batteries Dimensions 164 x 29 x 20mm (6.5 x 1.1 x 0.79”) Packing List Elcometer 138 Conductivity Meter, 14ml (0.5fl oz) bottle of conditioning solution, 14ml (0.5fl oz) bottle of standard 1413μS/cm calibration solution, 2 x CR2032 lithium batteries and operating instructions
-
- Downloads
-
Downloads
-
Elcometer 138 Conductivity Meter Instruction Manual
-
Elcometer 138 Conductivity Meter Datasheet
-
Elcometer 138 Conductivity Meter CE Declaration of Conformity
-
Elcometer 138 Conductivity Meter UKCA Declaration of Conformity
-
Elcometer 138 Standard 1413μS/cm Calibration Solution Material Safety Data Sheet
- Part Numbers
-
Part NumbersElcometer 138 Conductivity MeterNo data found!!
-
Elcometer 138 Conductivity Meter
- Part Number : E138-CM
- Accessories
-
AccessoriesElcometer 138 Conductivity Meter
- Part Number: T13830628
- Part Number: T13830629-2
-
- Home
- Coatings Inspection
- Coatings Inspection Division
- Surface Cleanliness
- Elcometer 138 Conductivity Meter
Elcometer 138 Conductivity Meter
- Protective Coatings
- Industrial Finishing
Incorporating a flat sensor, the Elcometer 138 Conductivity Meter can measure the conductivity of a solution from a single drop of a sample.
Summary
Elcometer 138 Conductivity Meter
Users can either place a sample on the meter’s flat sensor or immerse the meter’s sensor directly into the solution under test. The Elcometer 138 can be used for a broad range of applications, including: soluble salt concentrations, the electric conductivity (EC) of solutions used in agricultural operations and measuring rainwater pollution levels.
The Elcometer 138 Conductivity Meter includes a convenient salinity conversion indicator.
Features:
- Highly precise measurements can be obtained from a single drop
- Automatic range switching gives a wide measurement range of 1μS/cm to 19.99mS/cm
- Out of range and low battery alarms
- Visual indication when ambient temperature is outside the operating range
Downloads-
Elcometer 138 Conductivity Meter Instruction Manual
-
Elcometer 138 Conductivity Meter Datasheet
-
Elcometer 138 Conductivity Meter CE Declaration of Conformity
-
Elcometer 138 Conductivity Meter UKCA Declaration of Conformity
-
Elcometer 138 Standard 1413μS/cm Calibration Solution Material Safety Data Sheet
Technical SpecificationElcometer 138 Conductivity MeterPart Number Description E138-CM Elcometer 138 Conductivity Meter Measurement Principle Measurement Principle Measurement Mode Conductivity, Temperature Minimum Sample Volume 0.12ml Measuring Range 0 - 19.99mS/cm Resolution 0 - 1999μS/cm: 1μS/cm
2.00 - 19.99mS/cm: 0.01mS/cmAccuracy ±2% full scale (for each range) Operating Temperature 5°C to 40°C (41°F to 104°F) Operating Humidity 85% or less relative humidity (no condensation) Battery Type 2 x CR2032 lithium batteries Battery Life approx. 200 hours of continuous use without backlight Weight 50g (1.76oz) - including sensor and batteries Dimensions 164 x 29 x 20mm (6.5 x 1.1 x 0.79”) Packing List Elcometer 138 Conductivity Meter, 14ml (0.5fl oz) bottle of conditioning solution, 14ml (0.5fl oz) bottle of standard 1413μS/cm calibration solution, 2 x CR2032 lithium batteries and operating instructions Part NumbersElcometer 138 Conductivity MeterNo data found!!-
Elcometer 138 Conductivity Meter
- Part Number : E138-CM
AccessoriesElcometer 138 Conductivity Meter- Part Number: T13830628
- Part Number: T13830629-2
-
-