Elcometer 134S Chloride Ion Test Kit for Surfaces
- Protective Coatings

The Elcometer 134S Chloride Ion Test Kit for Surfaces allows the surface to be tested for chloride salts prior to application of a coating.
- Summary
-
Summary
-
Chloride salts left on the surface before the first coat is applied can result in the coating system being forced off the surface by corrosion or blistering before the full life of the coating has been reached.
To ensure that the chloride has been removed it is essential that the surface is tested before the coating is applied.
Elcometer 134S test method: a latex sleeve is filled with a Chlor*Rid extract solution and stuck to the test surface where the solution is worked against the surface to extract the salts. The titration tube is inserted and the results can be recorded.
-
- Key Features
-
Key Features
Elcometer 134S Chloride Ion Test Kit for Surfaces
How to use a Chloride Ion Test Kit for Surfaces
1. Remove cap from CHLOR*EXTRACT solution bottle and pour entire contents into the test sleeve.
2. Firmly apply test sleeve to test surface, allowing extract solution to come into contact with test surface.
3. Insert the titration tube into the test sleeve.
-
- Technical Information
-
Technical SpecificationElcometer 134S Chloride Ion Test Kit for Surfaces
Part Number Description E134----1 Elcometer 134S Salt Detection Kit for Blast Cleaned Surfaces Measuring Range 1 - 60μg/cm² (1 - 60ppm) Tests per Kit 5 Scale Resolution 1μg/cm² (1ppm) Dimensions 185 x 125 x 110mm (7 x 5 x 4.5”) Weight 250g (9oz) Packing List 5 x test kits each containing: titration tube snapper, strap, clip, pre-measured bottle of Chlor*Rid extract solution, sleeve, titration tube and operating instructions
-
- Standards
-
StandardsElcometer 134S Chloride Ion Test Kit for Surfaces
ISO 8502-5, SSPC Guide 15
-
- Downloads
-
Downloads
- Part Numbers
-
Part NumbersElcometer 134S Chloride Ion Test Kit for SurfacesNo data found!!
-
Elcometer 134S Chloride Ion Test Kit for Surfaces
- Part Number : E134----1
-
- Home
- Coatings Inspection
- Coatings Inspection Division
- Surface Cleanliness
- Elcometer 134S Chloride Ion Test Kit for Surfaces
Elcometer 134S Chloride Ion Test Kit for Surfaces
- Protective Coatings
The Elcometer 134S Chloride Ion Test Kit for Surfaces allows the surface to be tested for chloride salts prior to application of a coating.
Summary
Elcometer 134S Chloride Ion Test Kit for Surfaces
Chloride salts left on the surface before the first coat is applied can result in the coating system being forced off the surface by corrosion or blistering before the full life of the coating has been reached.
To ensure that the chloride has been removed it is essential that the surface is tested before the coating is applied.
Elcometer 134S test method: a latex sleeve is filled with a Chlor*Rid extract solution and stuck to the test surface where the solution is worked against the surface to extract the salts. The titration tube is inserted and the results can be recorded.
Key Features
Elcometer 134S Chloride Ion Test Kit for Surfaces
How to use a Chloride Ion Test Kit for Surfaces
1. Remove cap from CHLOR*EXTRACT solution bottle and pour entire contents into the test sleeve.
2. Firmly apply test sleeve to test surface, allowing extract solution to come into contact with test surface.
3. Insert the titration tube into the test sleeve.
Technical SpecificationElcometer 134S Chloride Ion Test Kit for SurfacesPart Number Description E134----1 Elcometer 134S Salt Detection Kit for Blast Cleaned Surfaces Measuring Range 1 - 60μg/cm² (1 - 60ppm) Tests per Kit 5 Scale Resolution 1μg/cm² (1ppm) Dimensions 185 x 125 x 110mm (7 x 5 x 4.5”) Weight 250g (9oz) Packing List 5 x test kits each containing: titration tube snapper, strap, clip, pre-measured bottle of Chlor*Rid extract solution, sleeve, titration tube and operating instructions Part NumbersElcometer 134S Chloride Ion Test Kit for SurfacesNo data found!!-
Elcometer 134S Chloride Ion Test Kit for Surfaces
- Part Number : E134----1