The PTG8 is the top of the range gauge with all the features and functionality necessary for measuring, with precision, material thickness on virtually any material.
With a user definable display, users can choose to view readings, statistical information, bar graph together with the highest (Hi); lowest (Lo); and average (x); reading or a run chart; a trend graph of the last 20 readings.
Measurement Mode
In Scan Mode, readings can be taken at a rate of 16Hz (16 readings per second) over a large surface area. When the transducer is lifted off the surface, the average, lowest and highest thickness values are displayed.
Calibration Options
The PTG8 allows users to store into memory up to three calibrations. Once saved the user can select a calibration without the need to re-calibrate the gauge, ideal for users who are measuring a variety of materials or thicknesses.
Using the gauge’s alpha-numeric function, calibration memories can be re-named to suit the calibration setting.
Display Modes
The PTG8 has user definable upper and lower limits with audible and visual pass/fail warnings. Limits can be set for individual readings or for each batch. If a measurement is taken which falls outside set limits, the reading value and the limit icon turns red, the red LED flashes and the alarm beeps.
The PTG8 has Differential Mode; once a user defined nominal thickness value is set, the gauge displays the measured thickness together with the variation from the set nominal value thus indicating areas of the material which are thinner or thicker than expected.
The PTG8 offers B-Scan, a time based, cross sectional 2 dimentional graphical view of the material under test, ideal for relative depth analysis. The zoom of the B-Scan reading can either be set to automatic or can be defined by the user to focus on areas of interest.
Data Logging
The PTG8 can store 100,000 readings in up to 1,000 sequential or grid type batches. Using grid batching, readings are stored in a spreadsheet type format. The Obst feature, allows the user to record an obstruction within the grid.
Data Output
Compatible with ElcoMaster®, PC & Mobile Apps, readings can be downloaded via USB or Bluetooth® to PC, iOS or Android™ devices for further analysis and reporting.
|
Features:
|
Elcometer PTG Model 8: Made for iPhone 6 Plus, iPhone 6, iPhone 5S, iPhone 5C, iPhone 5, iPhone 4S, iPhone 4, iPad (4th generation), iPad mini, iPad 2, and iPod touch (4th and 5th generation).“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.
iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android software version 2.1 and upwards. All other trademarks acknowledged.
Part Number (with Transducer)1 |
PTG8BDL-TXC | |||
Part Number (gauge only) |
PTG8BDL | |||
Easy to use menu structure in multiple languages |
■ | |||
Tough, impact, waterproof and dust resistant equivalent to IP54 |
■ | |||
Bright colour screen with permanent backlight |
■ | |||
Ambient light sensor, with adjustable brightness |
■ | |||
Scratch and solvent resistant display; 2.4" (6cm) TFT |
■ | |||
Large positive feedback buttons |
■ | |||
USB power supply via PC |
■ | |||
Gauge software updates2 via ElcoMaster® Software |
■ | |||
2 year gauge warranty3 |
■ | |||
Limits: 40 definable audible & visual pass/fail warnings |
||||
Measurement Rate |
4, 8, 16Hz4 | |||
Measurement Mode |
Range5 | Accuracy6 | ||
Echo-Echo (E-E) |
0.15-10.15mm (0.006-0.400") |
±0.015mm (0.15-2.99mm) ±0.5% (3.00-10.15mm) |
±0.0006" (0.006-0.117") ±0.5% (0.118-0.400") |
■ |
Interface Echo (I-E) |
1.65-25.40mm (0.065-1.000") |
±0.015mm (1.65-2.99mm) ±0.5%(3.00-25.4mm) |
±0.0006" (0.065-0.117") ±0.5% (0.118-1.000") |
■ |
Plastic Mode (PLAS) |
0.15-5.00mm (0.006-0.197") |
±0.015mm (0.15-2.99mm) ±0.5% (3.00-5.00mm) |
±0.0006" (0.006-0.117") ±0.5% (0.118-0.197") |
■ |
Measurement Units |
mm or inches | |||
Repeatability / Stability Indicator |
■ | |||
Display Mode |
| |||
Reading |
■ | |||
Selected statistics |
■ | |||
Scan thickness bar graph |
■ | |||
Run Chart |
■ | |||
Readings and Differential |
■ | |||
B-Scan cross sectional display |
■ | |||
Selectable Reading Resolution |
||||
Lo; 0.1mm, 0.01 Inch, 10m/s, or 0.001 in/μs |
■ | |||
Hi; 0.01mm, 0.001 Inch, 1m/s, or 0.0001 in/μs |
■ | |||
Statistics |
||||
Number of readings,n; Mean average, x ; Standard deviation, σ. |
■ | |||
Lowest reading, Lo; Highest reading, Hi |
■ | |||
Low / high limit value |
■ | |||
Reading Range Value |
■ | |||
Nominal Value |
■ | |||
Number of readings below low limit |
■ | |||
Number of readings above high limit |
■ | |||
Calibration Options |
||||
1 - point |
■ | |||
2 - point |
■ | |||
Material selection; 39 preset materials |
■ | |||
Factory; resets to the factory calibration |
■ | |||
Velocity (speed of sound) |
■ | |||
Calibration Features |
||||
Calibration lock; with optional PIN Lock |
■ | |||
Test calibration feature |
■ | |||
Calibration memories: 3 programmable memories |
■ | |||
Measurement outside calibration warning |
■ | |||
Data Logging |
||||
Number of readings |
100,000 | |||
Number of batches |
1,000 | |||
Sequential batching |
■ | |||
Grid batching |
■ | |||
Fixed batch size mode; with batch linking |
■ | |||
Obstruct entry; add 'obst' into grid location |
■ | |||
Delete last reading |
■ | |||
Date & time stamp |
■ | |||
Review, clear & delete batches |
■ | |||
Alpha numeric batch names; user definable |
■ | |||
Batch review graph |
■ | |||
Data Output |
||||
USB to PC |
■ | |||
Bluetooth® to PC, AndroidTM & iOS devices |
■ | |||
ElcoMaster® software |
■ | |||
Transducer Probe Type |
Single Element | |||
Auto transducer recognition |
■ | |||
Auto V-path correction |
■ | |||
Battery Type7 |
2 x AA | |||
Battery Life7 |
Alkaline: 15 hours Lithium: 28 hours | |||
Operating Temperature |
-10 to 50°C (14 to 122°F) | |||
Size (w x h x d) |
145 x 73 x 37mm (5.7 x 2.84 x 1.46") | |||
Weight (including batteries) |
210g (7.4oz) | |||
Packing List |
Elcometer PTG8BDL, 15MHz 1/4" Microdot right angle single element transducer, couplant, wrist harness, 3 x screen protector, protective case, plastic transit case, 2 x AA batteries, calibration certificate, USB cable, ElcoMaster® Software, two year warranty extension card, operating instructions |
STANDARDS:
EN14127, EN15317
1 Supplied with 15MHz 1/4"Microdot right angle single element transducer
2 Internet connection required
3 The Elcometer MTG range is extendable within 60 days from date of purchase, free of charge to two years
4 User selectable default setting in scan mode is 16 Hz
5 Dependent on the material being measured and the transducer being used
6 On steel
7 Supplied with Alkaline, Lithium and rechargable can be used with the gauges, continuous use at 1 reading per second
PTG Transducers | |
The PTG range of intelligent single element transducers has an automatic transducer recognition which ensures correct probe identification even when the transducer is changed. | ![]() |
|
|
|
|
Suitable for measuring |
Suitable for | |||
Part Number |
Probe Diameter |
Probe Characteristic |
Damping |
Thin Plastics |
Steel |
Aluminium |
Titanium |
PTG6 PTG8 |
15.0 MHz Single Element Transducer | ||||||||
TXC15M0CM |
1/4" |
Right Angle |
S |
■ |
■ |
■ |
■ |
■ |
20.0 MHz Single Element Transducer | ||||||||
TXC20M0CM |
1/4" |
Right Angle |
S |
■ |
■ |
■ |
■ |
■ |
All transducers are supplied with a calibration certificate.
Calibration Standard Sets | ||
Part Number | Description | |
T920CALSTD-SET1 |
Calibration Standard Set; Nominal Thickness; 2-30mm (0.08-1.18")1 Comprising of nominal thickness; 2, 5, 10, 15, 20, 25 & 30mm (0.08, 0.20, 0.39, 0.59, 0.79, 0.98 & 1.18"), complete with holder and calibration certificate. | |
T920CALSTD-SET2 |
Calibration Standard Set; Nominal Thickness; 40 - 100mm (1.57 - 3.94")1 Comprising of nominal thickness; 40, 50, 60, 70, 80, 90 & 100mm (1.57, 1.97, 2.36, 2.76, 3.15, 3.54 & 3.94"), complete with holder and calibration certificate | |
T920CALSTD-HLD |
Calibration Holder; for thicknesses up to 100mm (3.94") | |
Individual Calibration Standards | ||
Part Number |
Nominal Thickness (mm) |
Nominal Thickness (inches)1 |
T920CALSTD-2 |
2 | 0.078 |
T920CALSTD-5 |
5 | 0.196 |
T920CALSTD-10 |
10 | 0.393 |
T920CALSTD-15 |
15 | 0.590 |
T920CALSTD-20 |
20 | 0.787 |
T920CALSTD-25 |
25 |
0.984 |
T920CALSTD-30 |
30 | 1.181 |
T920CALSTD-40 |
40 | 1.574 |
T920CALSTD-50 |
50 |
1.966 |
T920CALSTD-60 |
60 |
2.362 |
T920CALSTD-70 |
70 |
2.755 |
T920CALSTD-80 |
80 |
3.149 |
T920CALSTD-90 |
90 |
3.543 |
T920CALSTD-100 |
100 | 3.937 |
|
||
Ultrasonic Couplant | ||
T92015701 |
Ultrasonic Couplant; 120ml (4fl oz) | |
T92015701-5 |
Ultrasonic Couplant; 120ml (4fl oz), Pack of 5 Bottles | |
T92024034-7 |
Ultrasonic Couplant; 300ml (10fl oz) | |
T92024034-8 |
Ultrasonic Couplant; 500ml (17fl oz) | |
T92024034-3 |
Ultrasonic Couplant; 3.8l (1 US Gallon) | |
T92024034-9 |
High Temperature Couplant 371°C (700°F); 60ml (2fl oz) | |
T92024034-10 |
High Temperature Couplant 371°C (700°F); 60ml (2fl oz), Pack of 2 | |
|
| |
Transducer Adaptor
These adaptors allow single & dual element, 'non-intelligent' and other transducers with lemoconnectors from Elcometer NDT and other manufacturers, to be used with the MTG & PTG product range. | ||
Part Number |
Description | |
T92025657 |
Transducer Adaptor Single Element2 | |
|
| |
Delay Lines
Each single element transducer is supplied complete with 9mm and 12mm acrylic delay lines suitable for measuring on steel, aluminium and titanium. If measuring on thin plastics using Plastic Mode (PLAS), a graphite delay line must be used. | ||
Part Number |
Description | |
T92016528 |
Acrylic Delay Line; 1/4 Dia x 9mm | |
T92016529 |
Acrylic Delay Line; 1/4 Dia x 12mm | |
T92023853-4 |
Graphite Delay Line; 1/4 Dia x 3/8" |
1 Imperial values for information purposes only. Calibration standards are manufactured and measured in millimeters.
2 This adaptor allows single element, 'non-intelligent' and other transducers with Lemo Connectors from Elcometer and other manufacturers to be used with the PTG product range.
When it comes to measuring the thickness of small, thin, or intricate components, how do you quickly and non-destructively measure the thickness of the material, when you don’t have access to both sides? Typically, using an ultrasonic precision thickness gauge.
Click here to download the video script in English.
When it comes to measuring the thickness of small, thin, or intricate components, how do you quickly and non-destructively measure the thickness of the material, when you don’t have access to both sides? Typically, using an ultrasonic precision thickness gauge.
Click here to download the video script in English.
How to choose the correct Delay Line for your Elcometer PTG Ultrasonic Thickness Gauge
Measuring thin materials means that the ultrasonic signal will return to the transducer incredibly quickly, and as a result there is not always enough time between the pulse leaving the element, and the echo returning. This is why, when using an Elcometer PTG, single element transducers use a delay line, to increase the time between the pulse being sent and the echo being received, ensuring more accurate results.
Click here to download the video script in English.
Ultrasonic NDT gauges such as the Elcometer MTG Material Thickness Gauges, and the Elcometer PTG Precision Thickness Gauges; are designed to provide accurate, reliable material thickness measurements for a wide range of applications - including pipelines, storage tanks, rubber linings or thin plastic bottles for example.
Click here to download the video script in English.