Elcometer CG100 Corrosion Thickness Gauge


Top of the range and easy to use, the Elcometer CG100 Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.
- Summary
-
Summary
-
Intelligent
User definable limits for pass/fail indication
Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.
Powerful
Store each measurement for further analysis
Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into ElcoMaster® Software for further analysis and reporting.
Versatile
Able to measure coating and material thickness
The Elcometer CG100 has the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.
Customisable
Choose & customise the reading display
The Elcometer CG100 range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the CG100ABDL and CG100ABDL+.
The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.
- Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
- Manual or automatic gain control (AGC) with adjustable 110dB range
- Gate control
- Threshold adjustment
- 64 User defined setups
- Multiple language display
- Multiple calibration and material selection options
- High speed scan mode: 250 readings per second (CG100100B and CG100BDL), 50 readings per second (CG100ABDL and CG100ABDL+)
- A-Scan portrait & landscape views (CG100ABDL+ only)
- Differential and minimal thickness alarm modes
- Data output and storage: 4GB internal memory
- Download to ElcoMaster® data management software
-
- Key Features
-
Key Features
Elcometer CG100 Corrosion Thickness Gauge
CG100 Features Explained
Repeatability / Stability Indicator
Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.
High Speed Scan with Minimum Thickness Display
By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).
Differential Mode
Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.
Limit Alarm Mode
The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.
V-Path Correction
Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness
Measurement Modes Explained
Pulse - Echo Mode (PE):
The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.
Echo - Echo Mode (EE):
Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.
Pulse - Echo Temp Comp Mode (PETP):
Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations.
Echo - Echo Verify Mode (EEV):
The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.
Coating Only Mode (CT):
Displays the thickness of the coating applied to the material.
Pulse - Echo Coating Mode (PECT):
Displays both the material thickness (PE) and the coating thickness (CT) at the same time.
Basic Flaw Mode (FLAW MODE):
Basic prove-up flaw detection using single element angle beam transducers is available on the CG100ABDL and CG100ABDL+ corrosion thickness gauges.
Display Modes Explained
Material Thickness Digits Display:
The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).
Scan Bar Display:
A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.
B-Scan Display:
A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.
A-Scan Display; Full Wave (RF):*
The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.
A-Scan Display; Rectified (+ or -):*
Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.
* Available on CG100ABDL and CG100ABDL+ Models only
-
- Product Features
-
Product FeaturesElcometer CG100 Corrosion Thickness Gauge
Model CG100B CG100BDL CG100ABDL CG100ABDL+ Display Mode Material thickness digits display B-Scan cross sectional display Combined B-Scan and digits display Coating Thickness Display Scan Bar Display A-Scan Display + Rectified, - Rectified, Full Waveform (RF)+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape viewsMeasurement Range1 PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)Measurement Rate Manual 8 readings per second8 readings per second8 readings per second8 readings per secondScan Mode 250 readings per second250 readings per second50 readings per second50 readings per secondScan bar display 10 readings per second10 readings per second10 readings per second10 readings per secondMeasurement Resolution 0.01mm (0.001”)0.01mm (0.001”)0.01mm (0.001”), 0.001mm (0.0001”) selectable0.01mm (0.001”), 0.001mm (0.0001”) selectableVelocity Calibration Range 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)Additional Features Additional Features Differential Mode Limit alarm mode B-Scan Display Speed 10 to 200 readings per second10 to 200 readings per second10 to 200 readings per second10 to 200 readings per secondFlaw Mode Basic prove-up flaw detection using single element angle beam transducersBasic prove-up flaw detection using single element angle beam transducersCalibration Setups 64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archiveGates 3 fully adjustable gates: start, stop, width & threshold3 fully adjustable gates: start, stop, width & thresholdDamping Adjustable damping (50 - 1500ohms)Adjustable damping (50 - 1500ohms)Pulser Type Dual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzGain Manual or automatic gain control (AGC) with 110dB range (limited)Manual or automatic gain control (AGC) with 110dB range (limited)Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeManual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeTiming Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerMemory and Data Logging • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCalibration Options 1 - point 2 - point Material selection Velocity (speed of sound) Transducer Probe Type Dual elementDual elementDual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilDual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilTransducer Frequency Range 1 - 10MHz1 - 10MHz1 - 20MHz1 - 20MHzTransducer Recognition Automatic & manual - selectable from a listAutomatic & manual - selectable from a listAutomatic & manual - selectable from a listAutomatic & manual - selectable from a listV-path / dual path error correction AutomaticAutomaticAutomaticAutomaticProbe Zero Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Display •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape ModeDisplay Refresh Rate 25Hz25Hz25Hz60HzUnits (selectable) mm or inchesmm or inchesmm or inchesmm or inchesLED Backlight on/off/autoon/off/autoon/off/autoadjustable brightnessRepeatability / Stability Indicator Battery Save Mode AutoAutoAutoAutoDisplay Mode Material thickness digits display CG100B CG100BDL CG100ABDL CG100ABDL+ B-Scan cross sectional display CG100B CG100BDL CG100ABDL CG100ABDL+ Combined B-Scan and digits display CG100B CG100BDL CG100ABDL CG100ABDL+ Coating Thickness Display CG100B CG100BDL CG100ABDL CG100ABDL+ Scan Bar Display CG100B CG100BDL CG100ABDL CG100ABDL+ A-Scan Display CG100B CG100BDL CG100ABDL + Rectified, - Rectified, Full Waveform (RF)CG100ABDL+ + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape viewsMeasurement Range1 CG100B PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)CG100BDL PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)CG100ABDL PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)CG100ABDL+ PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)Measurement Rate Manual CG100B 8 readings per secondCG100BDL 8 readings per secondCG100ABDL 8 readings per secondCG100ABDL+ 8 readings per secondScan Mode CG100B 250 readings per secondCG100BDL 250 readings per secondCG100ABDL 50 readings per secondCG100ABDL+ 50 readings per secondScan bar display CG100B 10 readings per secondCG100BDL 10 readings per secondCG100ABDL 10 readings per secondCG100ABDL+ 10 readings per secondMeasurement Resolution CG100B 0.01mm (0.001”)CG100BDL 0.01mm (0.001”)CG100ABDL 0.01mm (0.001”), 0.001mm (0.0001”) selectableCG100ABDL+ 0.01mm (0.001”), 0.001mm (0.0001”) selectableVelocity Calibration Range CG100B 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100BDL 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100ABDL 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100ABDL+ 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)Additional Features Additional Features CG100B CG100BDL CG100ABDL CG100ABDL+ Differential Mode CG100B CG100BDL CG100ABDL CG100ABDL+ Limit alarm mode CG100B CG100BDL CG100ABDL CG100ABDL+ B-Scan Display Speed CG100B 10 to 200 readings per secondCG100BDL 10 to 200 readings per secondCG100ABDL 10 to 200 readings per secondCG100ABDL+ 10 to 200 readings per secondFlaw Mode CG100B CG100BDL CG100ABDL Basic prove-up flaw detection using single element angle beam transducersCG100ABDL+ Basic prove-up flaw detection using single element angle beam transducersCalibration Setups CG100B 64 user-definable setups transferable to and from a PC archiveCG100BDL 64 user-definable setups transferable to and from a PC archiveCG100ABDL 64 user-definable setups transferable to and from a PC archiveCG100ABDL+ 64 user-definable setups transferable to and from a PC archiveGates CG100B CG100BDL CG100ABDL 3 fully adjustable gates: start, stop, width & thresholdCG100ABDL+ 3 fully adjustable gates: start, stop, width & thresholdDamping CG100B CG100BDL CG100ABDL Adjustable damping (50 - 1500ohms)CG100ABDL+ Adjustable damping (50 - 1500ohms)Pulser Type CG100B Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100BDL Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100ABDL Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100ABDL+ Dual square wave pulsers
Pulse repetition frequency up to 250HzGain CG100B Manual or automatic gain control (AGC) with 110dB range (limited)CG100BDL Manual or automatic gain control (AGC) with 110dB range (limited)CG100ABDL Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeCG100ABDL+ Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeTiming CG100B Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100BDL Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100ABDL Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100ABDL+ Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerMemory and Data Logging CG100B CG100BDL • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCG100ABDL • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCG100ABDL+ • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCalibration Options 1 - point CG100B CG100BDL CG100ABDL CG100ABDL+ 2 - point CG100B CG100BDL CG100ABDL CG100ABDL+ Material selection CG100B CG100BDL CG100ABDL CG100ABDL+ Velocity (speed of sound) CG100B CG100BDL CG100ABDL CG100ABDL+ Transducer Probe Type CG100B Dual elementCG100BDL Dual elementCG100ABDL Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilCG100ABDL+ Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilTransducer Frequency Range CG100B 1 - 10MHzCG100BDL 1 - 10MHzCG100ABDL 1 - 20MHzCG100ABDL+ 1 - 20MHzTransducer Recognition CG100B Automatic & manual - selectable from a listCG100BDL Automatic & manual - selectable from a listCG100ABDL Automatic & manual - selectable from a listCG100ABDL+ Automatic & manual - selectable from a listV-path / dual path error correction CG100B AutomaticCG100BDL AutomaticCG100ABDL AutomaticCG100ABDL+ AutomaticProbe Zero CG100B Automatic & manual (via integrated probe disk)CG100BDL Automatic & manual (via integrated probe disk)CG100ABDL Automatic & manual (via integrated probe disk)CG100ABDL+ Automatic & manual (via integrated probe disk)Display CG100B •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100BDL •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100ABDL •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100ABDL+ •1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape ModeDisplay Refresh Rate CG100B 25HzCG100BDL 25HzCG100ABDL 25HzCG100ABDL+ 60HzUnits (selectable) CG100B mm or inchesCG100BDL mm or inchesCG100ABDL mm or inchesCG100ABDL+ mm or inchesLED Backlight CG100B on/off/autoCG100BDL on/off/autoCG100ABDL on/off/autoCG100ABDL+ adjustable brightnessRepeatability / Stability Indicator CG100B CG100BDL CG100ABDL CG100ABDL+ Battery Save Mode CG100B AutoCG100BDL AutoCG100ABDL AutoCG100ABDL+ Auto1 Measuring range & accuracy depends on material, surface conditions and the transducer selected
-
- Technical Information
-
Technical SpecificationElcometer CG100 Corrosion Thickness Gauge
Part Number Description Certificate CG100B Elcometer CG100B Corrosion Thickness Gauge CG100BDL Elcometer CG100BDL Corrosion Thickness Gauge CG100ABDL Elcometer CG100ABDL Corrosion Thickness Gauge CG100ABDL+ Elcometer CG100ABDL+ Corrosion Thickness Gauge Transducer Probe Type Dual Element Measurement Accuracy1 0.01mm (0.001”) Memory 4GB Internal Memory Operating Temperature -10 to 60ºC (14 to 140ºF) Data Output USB Power Supply 3 x AA batteries and via USB Battery Life2 Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs Gauge Weight 383g (13.5oz) - including batteries Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”) Packing List Elcometer NDT CG100 gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, ElcoMaster® software, transfer cable 1Measuring range & accuracy depends on material, surface conditions and the transducer selected
2Approximate battery life, when in continuous measurement mode.
● Test Certificate supplied as standard.
-
- Standards
-
StandardsElcometer CG100 Corrosion Thickness Gauge
ASTM E 797, EN 14127, EN 15317
-
- Downloads
-
Downloads
-
Elcometer NDT Model CG100B, CG100BDL & CG100ABDL Instruction Manual
-
Elcometer NDT Model CG100ABDL+ Instruction Manual
-
Elcometer CG100 Corrosion Thickness Gauges Datasheet
-
CG100B Corrosion Thickness Gauges Declaration of Conformity
-
CG100BDL Corrosion Thickness Gauges Declaration of Conformity
-
CG100ABDL Corrosion Thickness Gauges Declaration of Conformity
-
CG100ABDL+ Corrosion Thickness Gauges Declaration of Conformity
- Part Numbers
-
Part NumbersElcometer CG100 Corrosion Thickness GaugeNo data found!!
-
Elcometer CG100B Corrosion Thickness Gauge
The CG100B Corrosion Thickness Gauge featuring manual or automatic gain control (AGC) with adjustable 110dB range to increase the amplitude of the received echo to suit the material properties.
- Part Number : CG100B
- Certification : Test Certificate
-
Elcometer CG100BDL Corrosion Thickness Gauge
The CG100BDL Corrosion Thickness Gauge stores up to 4GB worth of readings with individual waveforms in alpha-numeric batches and full data logging through USB data output to ElcoMaster® data management software.
- Part Number : CG100BDL
- Certification : Test Certificate
-
Elcometer CG100ABDL Corrosion Thickness Gauge
The CG100ABDL Corrosion Thickness Gauge stores up to 4GB worth of readings with individual waveforms, displays A-Scan and B-Scan and offers full data logging through USB data output to ElcoMaster® data management software.
- Gates: 3 fully adjustable gates: start, stop, width & threshold
- Damping: Adjustable damping (50 - 1500ohms)
- Part Number : CG100ABDL
- Certification : Test Certificate
-
Elcometer CG100ABDL+ Corrosion Thickness Gauge
With its high contrasting colour display the CG100ABDL+ Corrosion Thickness Gauge has a refresh rate of 60Hz providing users with an instant measurement response.
- Gates: 3 fully adjustable gates: start, stop, width & threshold
- Damping: Adjustable damping (50 - 1500ohms)
- Part Number : CG100ABDL+
- Certification : Test Certificate
- Accessories
-
AccessoriesElcometer CG100 Corrosion Thickness Gauge
- Part NumberTC-24034-1
- Part NumberTC-24034-2
- Part NumberTC-24034-3
- Part NumberTC-24034-9
- Part NumberTL-24030-1
- Part NumberTL-24030-2
- Part NumberTL-24030-3
- Part NumberTL-24030-6
- Part NumberTL-24031
- Part NumberTL-24032
- Home
- Elcometer CG100 Corrosion Thickness Gauge
Elcometer CG100 Corrosion Thickness Gauge
Top of the range and easy to use, the Elcometer CG100 Corrosion Thickness Gauges provide inspectors with all the features necessary to measure the material and coating thickness at the same time.
- Summary
- Product Features
- Technical Information
- Standards
- Part Numbers
- Video
- Accessories
- Downloads
- Elcometer CG100
Intelligent
User definable limits for pass/fail indication
Set limits for pass/fail indication on individual reading or for each batch with audible & visual warnings.
Powerful
Store each measurement for further analysis
Up to 4GB of readings can be saved into the gauge memory as each measurement is taken, which can be downloaded later into an inspection application or into ElcoMaster® Software for further analysis and reporting.
Versatile
Able to measure coating and material thickness
The Elcometer CG100 has the ability to measure coatings and material thickness simultaneously while maintaining the ability to locate pits, flaws and defects in the material.
Customisable
Choose & customise the reading display
The Elcometer CG100 range has a choice of display modes allowing the user to select the most appropriate for their needs; Readings, B-Scan, B-Scan combined with readings, Scan bar & the A-Scan on the CG100ABDL and CG100ABDL+.
Summary
Elcometer CG100 Corrosion Thickness Gauge
The Elcometer CG100 ultrasonic corrosion thickness gauge is available in four models - from an entry level CG100B to the top of the range CG100ABDL+.
- Range of display & measurement options: Pulse-Echo, Echo-Echo, Pulse-Echo Temp, Comp Mode (PETP), Coating Only Mode (CT), Pulse-Echo Coating Mode (PECT)
- Manual or automatic gain control (AGC) with adjustable 110dB range
- Gate control
- Threshold adjustment
- 64 User defined setups
- Multiple language display
- Multiple calibration and material selection options
- High speed scan mode: 250 readings per second (CG100100B and CG100BDL), 50 readings per second (CG100ABDL and CG100ABDL+)
- A-Scan portrait & landscape views (CG100ABDL+ only)
- Differential and minimal thickness alarm modes
- Data output and storage: 4GB internal memory
- Download to ElcoMaster® data management software
Downloads-
Elcometer NDT Model CG100B, CG100BDL & CG100ABDL Instruction Manual
-
Elcometer NDT Model CG100ABDL+ Instruction Manual
-
Elcometer CG100 Corrosion Thickness Gauges Datasheet
-
CG100B Corrosion Thickness Gauges Declaration of Conformity
-
CG100BDL Corrosion Thickness Gauges Declaration of Conformity
-
CG100ABDL Corrosion Thickness Gauges Declaration of Conformity
-
CG100ABDL+ Corrosion Thickness Gauges Declaration of Conformity
Key Features
Elcometer CG100 Corrosion Thickness Gauge
CG100 Features Explained
Repeatability / Stability Indicator
Consisting of 6 vertical bars, when all the bars are fully illuminated and the last digit on the digital thickness value is stable, the gauge is reliably measuring the material thickness.
High Speed Scan with Minimum Thickness Display
By significantly increasing the measurement refresh rate this mode allows the user to make scanned passes over the test material. The smallest thickness value is held in memory and displayed when scanning is complete. This feature can also be used in conjunction with the minimum & maximum limit alarm feature (model dependant).
Differential Mode
Once a user defined nominal thickness value has been set, the gauge will display the +/- thickness difference from the nominal value entered.
Limit Alarm Mode
The user can define minimum and maximum thickness limits. If the measurement falls outside the upper or lower limit a red LED will light and the beeper sounds. A green LED will light to indicate an acceptable thickness.
V-Path Correction
Dual element transducers consist of a probe with two crystals (one to transmit and one to receive the sound pulse). The crystals are separated by an acoustic barrier - generating a 'V-shaped' sound path as the sound travels from one element to the other. This path is slightly longer than the direct path therefore V-path correction is used to calculate the correct thickness
Measurement Modes Explained
Pulse - Echo Mode (PE):
The normal display mode, measures the total thickness from the base of the transducer probe to the material density boundary (typically the back wall). Ideal for pit and flaw detection.
Echo - Echo Mode (EE):
Also known as the ThruPaint™ Mode, EE ignores the coating thickness, displaying the material thickness from the top surface of the material to the material density boundary.
Pulse - Echo Temp Comp Mode (PETP):
Similar to the PE mode, PETP takes into account and compensates for the variations in measurement caused by temperature variations.
Echo - Echo Verify Mode (EEV):
The echo-echo verify mode measures by comparing the values between 3 reflections and is commonly used to eliminate errors from surface coatings and to make measurements in multiple layered materials.
Coating Only Mode (CT):
Displays the thickness of the coating applied to the material.
Pulse - Echo Coating Mode (PECT):
Displays both the material thickness (PE) and the coating thickness (CT) at the same time.
Basic Flaw Mode (FLAW MODE):
Basic prove-up flaw detection using single element angle beam transducers is available on the CG100ABDL and CG100ABDL+ corrosion thickness gauges.
Display Modes Explained
Material Thickness Digits Display:
The standard display on all models, this displays the numerical thickness value in either millimetres (MM)or inches (IN).
Scan Bar Display:
A linear graphic display which allows users to graphically monitor changes in thickness readings. As the scale range can be adjusted by the user, this display is ideal for observing tiny variations in material thicknesses.
B-Scan Display:
A time based cross sectional 2D block view of the thickness provides a graphical view of the material thickness - ideal for relative depth analysis.
A-Scan Display; Full Wave (RF):*
The A-Scan display shows the sine wave created by the reflected sound, or oscillation, from the material being measured. In RF mode the full wave form is displayed.
A-Scan Display; Rectified (+ or -):*
Users can select to view either the positive or the negative cycle of the full waveform (RF). This rectified (RECT) display shows the amplitude of the echo versus the transit time.
* Available on CG100ABDL and CG100ABDL+ Models only
Product FeaturesElcometer CG100 Corrosion Thickness GaugeModel CG100B CG100BDL CG100ABDL CG100ABDL+ Display Mode Material thickness digits display B-Scan cross sectional display Combined B-Scan and digits display Coating Thickness Display Scan Bar Display A-Scan Display + Rectified, - Rectified, Full Waveform (RF)+ Rectified, - Rectified, Full Waveform (RF) Portrait & landscape viewsMeasurement Range1 PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)Measurement Rate Manual 8 readings per second8 readings per second8 readings per second8 readings per secondScan Mode 250 readings per second250 readings per second50 readings per second50 readings per secondScan bar display 10 readings per second10 readings per second10 readings per second10 readings per secondMeasurement Resolution 0.01mm (0.001”)0.01mm (0.001”)0.01mm (0.001”), 0.001mm (0.0001”) selectable0.01mm (0.001”), 0.001mm (0.0001”) selectableVelocity Calibration Range 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)309.88 - 18,542m/s (0.0122 - 0.7300in/µs)Additional Features Additional Features Differential Mode Limit alarm mode B-Scan Display Speed 10 to 200 readings per second10 to 200 readings per second10 to 200 readings per second10 to 200 readings per secondFlaw Mode Basic prove-up flaw detection using single element angle beam transducersBasic prove-up flaw detection using single element angle beam transducersCalibration Setups 64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archive64 user-definable setups transferable to and from a PC archiveGates 3 fully adjustable gates: start, stop, width & threshold3 fully adjustable gates: start, stop, width & thresholdDamping Adjustable damping (50 - 1500ohms)Adjustable damping (50 - 1500ohms)Pulser Type Dual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzDual square wave pulsers
Pulse repetition frequency up to 250HzGain Manual or automatic gain control (AGC) with 110dB range (limited)Manual or automatic gain control (AGC) with 110dB range (limited)Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeManual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeTiming Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerPrecision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerMemory and Data Logging • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewer• 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCalibration Options 1 - point 2 - point Material selection Velocity (speed of sound) Transducer Probe Type Dual elementDual elementDual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilDual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilTransducer Frequency Range 1 - 10MHz1 - 10MHz1 - 20MHz1 - 20MHzTransducer Recognition Automatic & manual - selectable from a listAutomatic & manual - selectable from a listAutomatic & manual - selectable from a listAutomatic & manual - selectable from a listV-path / dual path error correction AutomaticAutomaticAutomaticAutomaticProbe Zero Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Automatic & manual (via integrated probe disk)Display •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable area•1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape ModeDisplay Refresh Rate 25Hz25Hz25Hz60HzUnits (selectable) mm or inchesmm or inchesmm or inchesmm or inchesLED Backlight on/off/autoon/off/autoon/off/autoadjustable brightnessRepeatability / Stability Indicator Battery Save Mode AutoAutoAutoAutoDisplay Mode Material thickness digits display CG100B CG100BDL CG100ABDL CG100ABDL+ B-Scan cross sectional display CG100B CG100BDL CG100ABDL CG100ABDL+ Combined B-Scan and digits display CG100B CG100BDL CG100ABDL CG100ABDL+ Coating Thickness Display CG100B CG100BDL CG100ABDL CG100ABDL+ Scan Bar Display CG100B CG100BDL CG100ABDL CG100ABDL+ A-Scan Display CG100B CG100BDL CG100ABDL + Rectified, - Rectified, Full Waveform (RF)CG100ABDL+ + Rectified, - Rectified, Full Waveform (RF) Portrait & landscape viewsMeasurement Range1 CG100B PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)CG100BDL PE: 0.63 - 1219.2mm (0.025 - 48”)
PETP: 0.63 - 1219.2mm (0.025 - 48”)
EE: 2.54 - 152.4mm (0.100 - 6.0“)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
CT: 0.01 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 1219.2mm (0.025 - 48”)CG100ABDL PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)CG100ABDL+ PE: 0.63 - 3br>PETP: 0.63 - 30,480mm (0.025 - 1200”)
EE: 2.54 - 152.4mm (0.100 - 6.0”)
EEV: 2.54 - 25.4mm (0.100 - 1.0”)
, CT: 0.0127 - 2.54mm (0.0005 - 0.100”)
PECT: 0.63 - 30,480mm (0.025 - 1200”)
PECT: 0.01 - 2.54mm (0.001 - 0.100”)Measurement Rate Manual CG100B 8 readings per secondCG100BDL 8 readings per secondCG100ABDL 8 readings per secondCG100ABDL+ 8 readings per secondScan Mode CG100B 250 readings per secondCG100BDL 250 readings per secondCG100ABDL 50 readings per secondCG100ABDL+ 50 readings per secondScan bar display CG100B 10 readings per secondCG100BDL 10 readings per secondCG100ABDL 10 readings per secondCG100ABDL+ 10 readings per secondMeasurement Resolution CG100B 0.01mm (0.001”)CG100BDL 0.01mm (0.001”)CG100ABDL 0.01mm (0.001”), 0.001mm (0.0001”) selectableCG100ABDL+ 0.01mm (0.001”), 0.001mm (0.0001”) selectableVelocity Calibration Range CG100B 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100BDL 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100ABDL 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)CG100ABDL+ 309.88 - 18,542m/s (0.0122 - 0.7300in/µs)Additional Features Additional Features CG100B CG100BDL CG100ABDL CG100ABDL+ Differential Mode CG100B CG100BDL CG100ABDL CG100ABDL+ Limit alarm mode CG100B CG100BDL CG100ABDL CG100ABDL+ B-Scan Display Speed CG100B 10 to 200 readings per secondCG100BDL 10 to 200 readings per secondCG100ABDL 10 to 200 readings per secondCG100ABDL+ 10 to 200 readings per secondFlaw Mode CG100B CG100BDL CG100ABDL Basic prove-up flaw detection using single element angle beam transducersCG100ABDL+ Basic prove-up flaw detection using single element angle beam transducersCalibration Setups CG100B 64 user-definable setups transferable to and from a PC archiveCG100BDL 64 user-definable setups transferable to and from a PC archiveCG100ABDL 64 user-definable setups transferable to and from a PC archiveCG100ABDL+ 64 user-definable setups transferable to and from a PC archiveGates CG100B CG100BDL CG100ABDL 3 fully adjustable gates: start, stop, width & thresholdCG100ABDL+ 3 fully adjustable gates: start, stop, width & thresholdDamping CG100B CG100BDL CG100ABDL Adjustable damping (50 - 1500ohms)CG100ABDL+ Adjustable damping (50 - 1500ohms)Pulser Type CG100B Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100BDL Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100ABDL Dual square wave pulsers
Pulse repetition frequency up to 250HzCG100ABDL+ Dual square wave pulsers
Pulse repetition frequency up to 250HzGain CG100B Manual or automatic gain control (AGC) with 110dB range (limited)CG100BDL Manual or automatic gain control (AGC) with 110dB range (limited)CG100ABDL Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeCG100ABDL+ Manual, automatic gain control (AGC) with 110dB range (limited), Linear time dependent gain (TDG) with adjustable slopeTiming CG100B Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100BDL Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100ABDL Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerCG100ABDL+ Precision temperature controlled crystal oscillator (TCXO) timing with single shot 100MHz 8bit ultra-low power digitizerMemory and Data Logging CG100B CG100BDL • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCG100ABDL • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCG100ABDL+ • 4GB internal memory
• Sequential and grid logging
• Alpha numeric batch identification
• OBSTRUCT indicates inaccessible locations
• Bitmap graphic capture and capture viewerCalibration Options 1 - point CG100B CG100BDL CG100ABDL CG100ABDL+ 2 - point CG100B CG100BDL CG100ABDL CG100ABDL+ Material selection CG100B CG100BDL CG100ABDL CG100ABDL+ Velocity (speed of sound) CG100B CG100BDL CG100ABDL CG100ABDL+ Transducer Probe Type CG100B Dual elementCG100BDL Dual elementCG100ABDL Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilCG100ABDL+ Dual Element, Single Element (1 - 20Mhz), Contact, Matching Layer, Delay Line and PencilTransducer Frequency Range CG100B 1 - 10MHzCG100BDL 1 - 10MHzCG100ABDL 1 - 20MHzCG100ABDL+ 1 - 20MHzTransducer Recognition CG100B Automatic & manual - selectable from a listCG100BDL Automatic & manual - selectable from a listCG100ABDL Automatic & manual - selectable from a listCG100ABDL+ Automatic & manual - selectable from a listV-path / dual path error correction CG100B AutomaticCG100BDL AutomaticCG100ABDL AutomaticCG100ABDL+ AutomaticProbe Zero CG100B Automatic & manual (via integrated probe disk)CG100BDL Automatic & manual (via integrated probe disk)CG100ABDL Automatic & manual (via integrated probe disk)CG100ABDL+ Automatic & manual (via integrated probe disk)Display CG100B •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100BDL •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100ABDL •1/8 VGA (greyscale)
• 62 x 45.7mm (2.4 x 1.8”) viewable areaCG100ABDL+ •1/4 VGA AMOLED colour display
•57.6 x 43.2mm (2.27 x 1.78”) viewable area
•Landscape ModeDisplay Refresh Rate CG100B 25HzCG100BDL 25HzCG100ABDL 25HzCG100ABDL+ 60HzUnits (selectable) CG100B mm or inchesCG100BDL mm or inchesCG100ABDL mm or inchesCG100ABDL+ mm or inchesLED Backlight CG100B on/off/autoCG100BDL on/off/autoCG100ABDL on/off/autoCG100ABDL+ adjustable brightnessRepeatability / Stability Indicator CG100B CG100BDL CG100ABDL CG100ABDL+ Battery Save Mode CG100B AutoCG100BDL AutoCG100ABDL AutoCG100ABDL+ Auto1 Measuring range & accuracy depends on material, surface conditions and the transducer selected
Technical SpecificationElcometer CG100 Corrosion Thickness GaugePart Number Description Certificate CG100B Elcometer CG100B Corrosion Thickness Gauge CG100BDL Elcometer CG100BDL Corrosion Thickness Gauge CG100ABDL Elcometer CG100ABDL Corrosion Thickness Gauge CG100ABDL+ Elcometer CG100ABDL+ Corrosion Thickness Gauge Transducer Probe Type Dual Element Measurement Accuracy1 0.01mm (0.001”) Memory 4GB Internal Memory Operating Temperature -10 to 60ºC (14 to 140ºF) Data Output USB Power Supply 3 x AA batteries and via USB Battery Life2 Alkaline: greyscale 35 hrs, colour 12 hrs, Nicad: greyscale 10 hrs, colour 5 hrs, NI-MH: greyscale 35 hrs, colour 12 hrs Gauge Weight 383g (13.5oz) - including batteries Gauge Dimensions 63.5 x 165 x 31.5mm (2.5 x 6.5 x 1.24”) Packing List Elcometer NDT CG100 gauge, couplant, carry case, user manual, test certificate, 3 x AA batteries, ElcoMaster® software, transfer cable 1Measuring range & accuracy depends on material, surface conditions and the transducer selected
2Approximate battery life, when in continuous measurement mode.
● Test Certificate supplied as standard.Part NumbersElcometer CG100 Corrosion Thickness GaugeNo data found!!-
Elcometer CG100B Corrosion Thickness Gauge
The CG100B Corrosion Thickness Gauge featuring manual or automatic gain control (AGC) with adjustable 110dB range to increase the amplitude of the received echo to suit the material properties.
- Part Number : CG100B
- Certification : Test Certificate
-
Elcometer CG100BDL Corrosion Thickness Gauge
The CG100BDL Corrosion Thickness Gauge stores up to 4GB worth of readings with individual waveforms in alpha-numeric batches and full data logging through USB data output to ElcoMaster® data management software.
- Part Number : CG100BDL
- Certification : Test Certificate
-
Elcometer CG100ABDL Corrosion Thickness Gauge
The CG100ABDL Corrosion Thickness Gauge stores up to 4GB worth of readings with individual waveforms, displays A-Scan and B-Scan and offers full data logging through USB data output to ElcoMaster® data management software.
- Gates: 3 fully adjustable gates: start, stop, width & threshold
- Damping: Adjustable damping (50 - 1500ohms)
- Part Number : CG100ABDL
- Certification : Test Certificate
-
Elcometer CG100ABDL+ Corrosion Thickness Gauge
With its high contrasting colour display the CG100ABDL+ Corrosion Thickness Gauge has a refresh rate of 60Hz providing users with an instant measurement response.
- Gates: 3 fully adjustable gates: start, stop, width & threshold
- Damping: Adjustable damping (50 - 1500ohms)
- Part Number : CG100ABDL+
- Certification : Test Certificate
AccessoriesElcometer CG100 Corrosion Thickness Gauge- Part Number: TC-24034-1
- Part Number: TC-24034-2
- Part Number: TC-24034-3
- Part Number: TC-24034-9
- Part Number: TL-24030-1
- Part Number: TL-24030-2
- Part Number: TL-24030-3
- Part Number: TL-24030-6
- Part Number: TL-24031
- Part Number: TL-24032
-
-