Elcometer Duct Deposit Measuring System

  • Industrial Finishing
intro-imageiduct-deposit-kit
intro-image-duct-deposit-kit-1

By using the Elcometer 456 Ferrous Top Gauge with the specially designed probe and duct cleaning templates, readings can be taken of the deposit thickness on a specific test area, before and after cleaning.

  • Summary
    • Summary

    • Controlling ducting deposits and monitoring their build-up is essential to maintain hygiene standards and reduce fire risks in heating and ventilation systems.

      The Elcometer 456 Duct Deposit Measuring System has been specifically designed to meet the requirements of the DTT (Deposit Thickness Test) in HVCA’s (Heating & Ventilation Contractor’s Association) Guide to Good Practice, for the measurement of dust and grease deposits within ventilation systems and kitchen ducts made of ferrous metals.

      ElcoMaster® software, supplied as standard with the Elcometer 456 Duct Deposit Measuring System includes a template designed specifically for reporting duct deposit measurements.

  • Technical Information
    • Technical Specification
      Elcometer Duct Deposit Measuring System
      Part Number Description Certificate
      A456CDUCT Elcometer Duct Deposit Measuring System
      Optional Calibration Certificate available
      Measurement Range 0 - 1500μm (0 - 60mils)
      Packing List Elcometer 456 Top Separate Gauge, Ferrous duct probe, duct cleaning template, precision foil set 25μm, 50μm, 125μm, 250μm, 500μm, 1000μm, 2mm (x2), ElcoMaster® Software, 2x AA batteries, wrist harness, carry case and operating instructions.
      Part Number Certificate
      A456CDUCT
      Optional Calibration Certificate available
      Description Elcometer Duct Deposit Measuring System
      Measurement Range 0 - 1500μm (0 - 60mils)
      Packing List Elcometer 456 Top Separate Gauge, Ferrous duct probe, duct cleaning template, precision foil set 25μm, 50μm, 125μm, 250μm, 500μm, 1000μm, 2mm (x2), ElcoMaster® Software, 2x AA batteries, wrist harness, carry case and operating instructions.
      Optional Calibration Certificate available.
  • Standards
    • Standards
      Elcometer Duct Deposit Measuring System

      AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, JIS K 5600-1-7, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

      Standards in grey have been superseded but are still recognised in some industries.

  • Downloads
    • Downloads
        • Elcometer Duct Deposit Measuring System Instruction Manual

        • Elcometer Duct Deposit Measuring System Datasheet

  • Part Numbers
    • Part Numbers
      Elcometer Duct Deposit Measuring System
      • Elcometer Duct Deposit Measuring System
        • Part Number : A456CDUCT
  • Accessories
    • Accessories
      Elcometer Duct Deposit Measuring System

      ElcoMaster®

      It’s not all about taking readings, it’s what you do with them that counts - save up to 30% of your working week by producing professional reports in seconds with ElcoMaster® Software.

      • Part Number: T99022255-8
      • Part Number: T99022255-8C
      • Part Number: T99920130
      • Part Number: T456CF2B
      • Part Number: T99913939
      • Part Number: T99913969

Elcometer Duct Deposit Measuring System

  • Industrial Finishing
intro-imageiduct-deposit-kit
intro-image-duct-deposit-kit-1

By using the Elcometer 456 Ferrous Top Gauge with the specially designed probe and duct cleaning templates, readings can be taken of the deposit thickness on a specific test area, before and after cleaning.

Summary

Elcometer Duct Deposit Measuring System

Controlling ducting deposits and monitoring their build-up is essential to maintain hygiene standards and reduce fire risks in heating and ventilation systems.

The Elcometer 456 Duct Deposit Measuring System has been specifically designed to meet the requirements of the DTT (Deposit Thickness Test) in HVCA’s (Heating & Ventilation Contractor’s Association) Guide to Good Practice, for the measurement of dust and grease deposits within ventilation systems and kitchen ducts made of ferrous metals.

ElcoMaster® software, supplied as standard with the Elcometer 456 Duct Deposit Measuring System includes a template designed specifically for reporting duct deposit measurements.

Downloads
    • Elcometer Duct Deposit Measuring System Instruction Manual

    • Elcometer Duct Deposit Measuring System Datasheet

Technical Specification
Elcometer Duct Deposit Measuring System
Part Number Description Certificate
A456CDUCT Elcometer Duct Deposit Measuring System
Optional Calibration Certificate available
Measurement Range 0 - 1500μm (0 - 60mils)
Packing List Elcometer 456 Top Separate Gauge, Ferrous duct probe, duct cleaning template, precision foil set 25μm, 50μm, 125μm, 250μm, 500μm, 1000μm, 2mm (x2), ElcoMaster® Software, 2x AA batteries, wrist harness, carry case and operating instructions.
Part Number Certificate
A456CDUCT
Optional Calibration Certificate available
Description Elcometer Duct Deposit Measuring System
Measurement Range 0 - 1500μm (0 - 60mils)
Packing List Elcometer 456 Top Separate Gauge, Ferrous duct probe, duct cleaning template, precision foil set 25μm, 50μm, 125μm, 250μm, 500μm, 1000μm, 2mm (x2), ElcoMaster® Software, 2x AA batteries, wrist harness, carry case and operating instructions.
Optional Calibration Certificate available.
Standards
Elcometer Duct Deposit Measuring System

AS 2331.1.4, AS 3894.3-B, AS/NZS 1580.108.1, ASTM B 499, ASTM D 1186-B, ASTM D 1400, ASTM D 7091, ASTM E 376, ASTM G 12, BS 3900-C5-6B, BS 3900-C5-6A, BS 5411-11, BS 5411-3, BS 5599, DIN 50981, DIN 50984, ECCA T1, EN 13523-1, IMO MSC.215(82), IMO MSC.244 (83), ISO 1461, ISO 19840, ISO 2063, ISO 2360, ISO 2808-6A, ISO 2808-6B, ISO 2808-7C, ISO 2808-7D, ISO 2808-12, JIS K 5600-1-7, NF T30-124, SS 184159, SSPC PA 2, US Navy PPI 63101-000, US Navy NSI 009-32

Standards in grey have been superseded but are still recognised in some industries.

Part Numbers
Elcometer Duct Deposit Measuring System
  • Elcometer Duct Deposit Measuring System
    • Part Number : A456CDUCT
   
Accessories
Elcometer Duct Deposit Measuring System

ElcoMaster®

It’s not all about taking readings, it’s what you do with them that counts - save up to 30% of your working week by producing professional reports in seconds with ElcoMaster® Software.

  • Part Number: T99022255-8
  • Part Number: T99022255-8C
  • Part Number: T99920130
  • Part Number: T456CF2B
  • Part Number: T99913939
  • Part Number: T99913969