Elcometer 5100 Payne Permeability Cup

  • Industrial Finishing
  • Paint Manufacture
  • Laboratory & Physical Test
5100-intro-1

The Elcometer 5100 Payne Permeability Cups are made of anodised aluminium and are used to determine the permeability of films of paints, varnish, plastic, cellophane, etc.

  • Summary
    • Summary

    • The water evaporates or is absorbed by the cups and, after a certain time, the weight change relative to the film thickness is calculated, indicating the degree of permeability or permeance.

  • Key Features
    • Key Features

      Elcometer 5100 Payne Permeability Cup

      How to use Payne Permeability Cups

      Prepare the film to be tested using a film applicator and suitable test chart.

        Disassemble the permeability cup.


      Fill with required liquid (typically water) or dry desiccant (absorbent).

      Place the film on to the cup and reassemble making sure the gasket is fitted.

      Weigh the prepared permeability cup and record the result (in grams).

      Leave for appropriate time, re-weigh, calculate the change in mass (∆m) & water vapour transmission rate.

  • Technical Information
    • Technical Specification
      Elcometer 5100 Payne Permeability Cup
      Part Number Description Area Volume
          cm2 inches2 cm3 inches3
      K0005100M201 Elcometer 5100/1 Payne Permeability Cup 10 1.55 15 0.91
      K0005100M202 Elcometer 5100/2 Payne Permeability Cup 30 4.65 50 3.05
      K0005100M203 Elcometer 5100/3 Payne Permeability Cup 30 4.65 75 4.58
      Packing List Elcometer 5100 Payne Permeability Cup, storage case and operating instructions
      Part Number Description
      K0005100M201 Elcometer 5100/1 Payne Permeability Cup
      Area
      cm2 inches2
      10 1.55
      Volume
      cm3 inches3
      15 0.91
      Part Number Description
      K0005100M202 Elcometer 5100/2 Payne Permeability Cup
      Area
      cm2 inches2
      30 4.65
      Volume
      cm3 inches3
      50 3.05
      Part Number Description
      K0005100M203 Elcometer 5100/3 Payne Permeability Cup
      Area
      cm2 inches2
      30 4.65
      Volume
      cm3 inches3
      75 4.58
      Packing List Elcometer 5100 Payne Permeability Cup, storage case and operating instructions
  • Standards
    • Standards
      Elcometer 5100 Payne Permeability Cup

      ASTM D1653, ASTM E96, ISO 7783-1, ISO 7783-2

  • Downloads
    • Downloads
        • Elcometer 5100 Payne Permeability Cups Instruction Manual

        • Elcometer 5100 Payne Permeability Cups Datasheet

  • Part Numbers
    • Part Numbers
      Elcometer 5100 Payne Permeability Cup
      • Elcometer 5100/1 Payne Permeability Cup
        • Part Number : K0005100M201
      • Elcometer 5100/2 Payne Permeability Cup
        • Part Number : K0005100M202
      • Elcometer 5100/3 Payne Permeability Cup
        • Part Number : K0005100M203
  • Accessories
    • Accessories
      Elcometer 5100 Payne Permeability Cup
      • Part Number: K0004695M112

Elcometer 5100 Payne Permeability Cup

  • Industrial Finishing
  • Paint Manufacture
  • Laboratory & Physical Test
5100-intro-1

The Elcometer 5100 Payne Permeability Cups are made of anodised aluminium and are used to determine the permeability of films of paints, varnish, plastic, cellophane, etc.

Summary

Elcometer 5100 Payne Permeability Cup

The water evaporates or is absorbed by the cups and, after a certain time, the weight change relative to the film thickness is calculated, indicating the degree of permeability or permeance.

Downloads
    • Elcometer 5100 Payne Permeability Cups Instruction Manual

    • Elcometer 5100 Payne Permeability Cups Datasheet

Key Features

Elcometer 5100 Payne Permeability Cup

How to use Payne Permeability Cups

Prepare the film to be tested using a film applicator and suitable test chart.

  Disassemble the permeability cup.


Fill with required liquid (typically water) or dry desiccant (absorbent).

Place the film on to the cup and reassemble making sure the gasket is fitted.

Weigh the prepared permeability cup and record the result (in grams).

Leave for appropriate time, re-weigh, calculate the change in mass (∆m) & water vapour transmission rate.

Technical Specification
Elcometer 5100 Payne Permeability Cup
Part Number Description Area Volume
    cm2 inches2 cm3 inches3
K0005100M201 Elcometer 5100/1 Payne Permeability Cup 10 1.55 15 0.91
K0005100M202 Elcometer 5100/2 Payne Permeability Cup 30 4.65 50 3.05
K0005100M203 Elcometer 5100/3 Payne Permeability Cup 30 4.65 75 4.58
Packing List Elcometer 5100 Payne Permeability Cup, storage case and operating instructions
Part Number Description
K0005100M201 Elcometer 5100/1 Payne Permeability Cup
Area
cm2 inches2
10 1.55
Volume
cm3 inches3
15 0.91
Part Number Description
K0005100M202 Elcometer 5100/2 Payne Permeability Cup
Area
cm2 inches2
30 4.65
Volume
cm3 inches3
50 3.05
Part Number Description
K0005100M203 Elcometer 5100/3 Payne Permeability Cup
Area
cm2 inches2
30 4.65
Volume
cm3 inches3
75 4.58
Packing List Elcometer 5100 Payne Permeability Cup, storage case and operating instructions
Standards
Elcometer 5100 Payne Permeability Cup

ASTM D1653, ASTM E96, ISO 7783-1, ISO 7783-2

Part Numbers
Elcometer 5100 Payne Permeability Cup
  • Elcometer 5100/1 Payne Permeability Cup
    • Part Number : K0005100M201
  • Elcometer 5100/2 Payne Permeability Cup
    • Part Number : K0005100M202
  • Elcometer 5100/3 Payne Permeability Cup
    • Part Number : K0005100M203
   
Accessories
Elcometer 5100 Payne Permeability Cup
  • Part Number: K0004695M112