Elcometer 456 Coating Thickness Gauge Probe Range

  • Protective Coatings
  • Industrial Finishing
456-probesIntro-Images
Elcometer 456 Probe Range

All Elcometer 456 Coating Thickness Gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.

  • Summary
    • Summary

    • Telescopic Probes for hard to reach places

      Ferrous Probes (F)

      • Ferrous probes measure non-magnetic coatings on ferromagnetic substrates
      • Elcometer 456 ferrous gauges accept any ferrous probe
      Non-Ferrous Probes

      Non-Ferrous Probes (N)

      • Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates
      • Elcometer 456 non-ferrous gauges accept any non-ferrous probe
      Dual FNF Probes

      Dual Probes (FNF)

      • Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection
      • Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes
      High Temperature PINIP Probe

      High Temperature

      • Elcometer probes have a maximum operating temperature of 80°C (176°F)*
      • Separate ferrous probes have a maximum operating temperature of 150°C (300°F)*
      • Hi-Temperature PINIP™ has a maximum operating temperature of 250°C (480°F)*
      *The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.

      Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.

      Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.

      Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.

  • Key Features
    • Key Features

      Elcometer 456 Coating Thickness Gauge Probe Range

      Straight Probes

      Standard Straight Probe

      Standard Straight Probe
      Standard probes measure coatings on both flat and curved surfaces.

      Anodising ProbeAnodising Probe
      Chemical resistant & washable - ideal for the anodising environment.

      Mini ProbeMini Probe
      Mini probes are ideal for harder to reach areas and edges.

      Waterproof ProbeWaterproof Probe
      Sealed for use underwater at depth, even in diving gloves.

      Soft Coatings ProbeSoft Coating Probe
      Large surface area probes are for soft materials (HVCA approved).

      Thick Coatings ProbeThick Coatings Probe
      Ideal for measuring coatings up to 31mm thick.

      Scan Probes

      Standard Scan ProbeStandard Scan Probe
      Rapidly scan large surface areas without damaging the probe or the coating.

      Ball Bearing Scan ProbeBall Bearing Scan Probe*
      Clip on adaptors for large coated structures, abrasive coatings and pre-construction primers.

      Angled Probes

      Right Angle ProbeRight Angle Probe
      Take readings in areas with restricted clearance.

      Mini Right Angle ProbeMini Right Angle Probe
      For measuring coatings on edges, narrow pipes or small surface areas.

      Telescopic ProbeTelescopic Probe
      Extending probes for hard to reach areas.

      45° Angle Probe45° Angle Probe
      Measure difficult to access or complex areas.

      Plug In Integral Probes (PINIP™)

      PINIP ProbePINIP™ Integral Probe
      Transforms a separate gauge into an integral gauge, ideal for single-handed use.

      High Temperture PINIP ProbeHi-Temperature PINIP™
      Measure coatings on ferrous substrates up to 250°C (480°F).

      Armoured Cable Probes

      Armoured ProbeF / FNF Armoured Probe
      Reinforced heavy duty cables reduce the risk of cable damage.

      *UK Patent Number: 2571577

  • Technical Information
    • Technical Specification
      Elcometer 456 Coating Thickness Gauge Probe Range
      Scale 0.5: Range : 0-500μm (0-20mils)
      Accuracya (±1-3% or ±0.1mil)
      Range 0-500μm (0-20mils)
      Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
      1μm: 100-500μm (0.1mil: 5-20mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CFM3---A 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CFM3R90A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      45° Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CFM3R45A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      Straight Mini Probe
      Probe Length: 150mm (5.90”)c
      T456CFM3---C 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      T456CFM3R90C 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      45° Angle Mini Probe
      Probe Length: 300mm (11.80”)c
      T456CFM3R45D 18mm (0.71”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
      Right Angle Mini Probe
      Probe Length: 300mm (11.80”)c
      T456CFM3R90D 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
       
      Non-Ferrous (N)
      Straight Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CNM3---A 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CNM3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Straight Mini Probe
      Probe Length: 150mm (5.90”)c
      T456CNM3---C 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      T456CNM3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Right Angle Mini Probe
      Probe Length: 400mm (15.70”)c
      T456CNM3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
       
      Non-Ferrous - Graphite (N)
      Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CNMG3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      T456CNMG3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Right Angle Mini Probe
      Probe Length: 400mm (15.70”)c
      T456CNMG3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
      Scale 1: Range : 0-1500μm (0-60mils)
      Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil)
      Ranged 0-1500μm (0-60mils)
      Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
      1μm: 100-1500μm (0.1mil: 5-60mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CF1S 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
      Straight Probe - sealed
      Probe Length: 45mm (1.77”)c
      T456CF1E 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
      Scan Probe
      Probe Length: 45mm (1.77”)c
      T456CF1U 86mm (3.38”) 15mm (0.59”) Flat Surface Flat Surface
      Scan Probe - armoured
      Probe Length: 45mm (1.77”)c
      T456CF1UARM 140mm (5.51”) 15mm (0.59”) Flat Surface Flat Surface
      90° Probe
      Probe Length: 45mm (1.77”)c
      T456CF1R 28mm (1.10”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
      90° Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CFM5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
      90° Mini Probe - sealed
      Probe Length: 45mm (1.77”)c
      T456CFME5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
      90° Mini Probe - sealed, 2m cable
      Probe Length: 45mm (1.77”)c
      T456CFME5R90A-2 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
      PINIP™ Integral Probe T456CF1P 170mm (6.69”) 4mm (0.16”) 4mm (0.16") 60mm (2.36")
       
      Non-Ferrous (N)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CN1S 85mm (3.35”) 4mm (0.16”) 10mm (0.39") 10mm (0.39")
      90° Probe
      Probe Length: 45mm (1.77”)c
      T456CN1R 28mm (1.10”) 4mm (0.16”) 10mm (0.39") 14mm (0.55")
      Mini 90° Probe
      Probe Length: 45mm (1.77”)c
      T456CNM5R90A 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
      Mini 90°Probe
      Probe Length: 150mm (5.90”)c
      T456CNM5R90C 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
      Mini 90° Probe
      Probe Length: 400mm (15.7”)c
      T456CNM5R90E 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
      Anodiser Probe
      Probe Length: 45mm (1.77”)c
      T456CN1AS 100mm (3.94”) 4mm (0.16”) 10mm (0.39") 14mm (0.55")
      PINIP™ Integral Probe T456CN1P 180mm (7.09”) 4mm (0.16”) 10mm (0.39") 50mm (1.97")
       
      Ferrous & Non-Ferrous (FNF)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CFNF1S 88mm (3.46”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
      N: 26mm (1.02")
      12.5mm (0.49")
      Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      T456CFNF1ARM 185mm (7.28") F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
      N: 26mm (1.02")
      12.5mm (0.49")
      Scan Probe
      Probe Length: 45mm (1.77”)c
      T456CFNF1U 89mm (3.50”) 15mm (0.59”) Flat Surface Flat Surface
      Right Angle Probe
      Probe Length: 45mm (1.77”)c
      T456CFNF1R 38mm (1.50”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
      N: 26mm (1.02")
      12.5mm (0.49")
      PINIP™ Integral Probe T456CFNF1P 180mm (7.09”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
      N: 26mm (1.02")
      65mm (2.56")
      Scale 2: Range : 0-5mm (0-200mils)
      Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil)
      Ranged 0-5mm (0-200mils)
      Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
      10μm: 1-5mm (1.0mil: 50-200mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CF2S 89mm (3.50”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
      Scan Probe
      Probe Length: 45mm (1.77”)c
      T456CF2U 90mm (3.54”) 15mm (0.59”) Flat Surface Flat Surface
      90° Probe
      Probe Length: 45mm (1.77”)c
      T456CF2R 32mm (1.26”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
      Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      T456CF2ARM 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
      Telescopic Probe
      Probe Length: 56-122cm (22-48”)c
      T456CF2T 36mm (1.42”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
      Soft Coating Probe
      Probe Length: 45mm (1.77”)c
      T456CF2B 89mm (3.50”) 8mm (0.32”) Flat Surface Flat Surface
      Waterproof Probe - 1m (3’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      Waterproof Probe - 5m (15’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW-5 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      Waterproof Probe - 15m (45’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW-15 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      Waterproof Probe - 30m (98’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW-30 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      Waterproof Probe - 50m (164’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW-50 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      Waterproof Probe - 75m (250’) cable
      Probe Length: 45mm (1.77”)c
      T456CF2SW-75 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
      PINIP™ Integral Probe T456CF2P 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36")
      Hi-Temperature PINIP™ T456CF2PHT 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36")
       
      Non-Ferrous (N)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CN2S 88mm (3.46”) 14mm (0.55”) 100mm (3.97") 150mm (5.90")
      PINIP™ Integral Probe T456CN2P 185mm (7.28") 14mm (0.55”) 100mm (3.97") 150mm (5.90")
      Scale 3: Range : 0-13mm (0-500mils)
      Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils)
      Ranged 0-13mm (0-500mils)
      Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
      10μm: 2-13mm (1.0mil: 100-500mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CF3S 102mm (4.02”) 14mm (0.55”) 15mm (0.59") 40mm (1.98")
      PINIP™ Integral Probe T456CF3P 184mm (7.24”) 14mm (0.55”) 15mm (0.59") 45mm (1.77")
       
      Non-Ferrous (N)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CN3S 170mm (6.69”) 35mm (1.38”) Flat Surface Flat Surface
      Scale FM7: Range: 0.60-3.8mm (25-150mils)
      Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils)
      Ranged 0.60-3.8mm (25-150mils)
      Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
      10μm: 1-3.8mm (1.0mil: 39.4-150mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      45° Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      T456CFM7R45A 20mm (0.79”) 6.5 mm (0.26’’) - -
      Scale 6: Range : F: 0-25mm (F: 0-980mils)
      N: 0-30mm (N: 0-1200mils)
      Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
      Ranged F: 0-25mm (F: 0-980mils)
      N: 0-30mm (N: 0-1200mils)
      Resolution 10μm: 0-2mm (1mil: 0-100mils)
      100μm: 2-30mm (10mils: 100-1200mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CF6S 150mm (5.90”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70")
      Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      T456CF6ARM 190mm (7.48”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70")
       
      Non-Ferrous (N)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CN6S 160mm (6.30”) 58mm (2.29”) Flat Surface Flat Surface
      Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      T456CN6ARM 200mm (7.87") 58mm (2.29”) Flat Surface Flat Surface
      Scale 7: Range : 0-31mm (0-1220mils)
      Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
      Ranged 0-31mm (0-1220mils)
      Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
      100μm: 2-31mm (10mils: 100-1220mils)
      Certificate
      Certificate supplied as standard
      DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
      Ferrous (F)
      Straight Probe armoured cable
      Probe Length: 45mm (1.77”)c
      T456CF7ARM 200mm (7.87") 55 x 55mm2 (2.17 x 2.17 inch2) 40mm (1.58") 170mm (6.70")
      Scale 0.5: Range : 0-500μm (0-20mils)
      Accuracya (±1-3% or ±0.1mil)
      Range 0-500μm (0-20mils)
      Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
      1μm: 100-500μm (0.1mil: 5-20mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CFM3---A
      Description Straight Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 6mm (0.24”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3R90A
      Description Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3R45A
      Description 45° Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3---C
      Description Straight Mini Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 6mm (0.24”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3R90C
      Description Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3R45D
      Description 45° Angle Mini Probe
      Probe Length: 300mm (11.80”)c
      Minimum Headroom 18mm (0.71”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFM3R90D
      Description Right Angle Mini Probe
      Probe Length: 300mm (11.80”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 3mm (0.12”)
      Minimum Convex Surface Diameter 1.9mm (0.07")
      Minimum Concave Surface Radius 6.5mm (0.26")
       
      Non-Ferrous (N)
      Part Number T456CNM3---A
      Description Straight Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 6mm (0.24”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM3R90A
      Description Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM3---C
      Description Straight Mini Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 6mm (0.24”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM3R90C
      Description Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM3R90E
      Description Right Angle Mini Probe
      Probe Length: 400mm (15.70”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
       
      Non-Ferrous - Graphite (N)
      Part Number T456CNMG3R90A
      Description Right Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNMG3R90C
      Description Right Angle Mini Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNMG3R90E
      Description Right Angle Mini Probe
      Probe Length: 400mm (15.70”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 6mm (0.24")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Scale 1: Range : 0-1500μm (0-60mils)
      Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil)
      Ranged 0-1500μm (0-60mils)
      Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
      1μm: 100-1500μm (0.1mil: 5-60mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CF1S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF1E
      Description Straight Probe - sealed
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF1U
      Description Scan Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 86mm (3.38”)
      Minimum Sample Diameterb 15mm (0.59”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Part Number T456CF1UARM
      Description Scan Probe - armoured
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 140mm (5.51”)
      Minimum Sample Diameterb 15mm (0.59”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Part Number T456CF1R
      Description 90° Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 28mm (1.10”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CFM5R90A
      Description 90° Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 3mm (0.12")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFME5R90A
      Description 90° Mini Probe - sealed
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 3mm (0.12")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CFME5R90A-2
      Description 90° Mini Probe - sealed, 2m cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 3mm (0.12")
      Minimum Concave Surface Radius 6.5mm (0.26")
      Part Number T456CF1P
      Description PINIP™ Integral Probe
      Minimum Headroom 170mm (6.69”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 60mm (2.36")
       
      Non-Ferrous (N)
      Part Number T456CN1S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 85mm (3.35”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 10mm (0.39")
      Part Number T456CN1R
      Description 90° Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 28mm (1.10”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 14mm (0.55")
      Part Number T456CNM5R90A
      Description Mini 90° Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM5R90C
      Description Mini 90°Probe
      Probe Length: 150mm (5.90”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CNM5R90E
      Description Mini 90° Probe
      Probe Length: 400mm (15.7”)c
      Minimum Headroom 16mm (0.63”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 8.5mm (0.33")
      Part Number T456CN1AS
      Description Anodiser Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 100mm (3.94”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 14mm (0.55")
      Part Number T456CN1P
      Description PINIP™ Integral Probe
      Minimum Headroom 180mm (7.09”)
      Minimum Sample Diameterb 4mm (0.16”)
      Minimum Convex Surface Diameter 10mm (0.39")
      Minimum Concave Surface Radius 50mm (1.97")
       
      Ferrous & Non-Ferrous (FNF)
      Part Number T456CFNF1S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 88mm (3.46”)
      Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
      Minimum Convex Surface Diameter F: 4mm (0.16")
      N: 26mm (1.02")
      Minimum Concave Surface Radius 12.5mm (0.49")
      Part Number T456CFNF1ARM
      Description Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 185mm (7.28")
      Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
      Minimum Convex Surface Diameter F: 4mm (0.16")
      N: 26mm (1.02")
      Minimum Concave Surface Radius 12.5mm (0.49")
      Part Number T456CFNF1U
      Description Scan Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 89mm (3.50”)
      Minimum Sample Diameterb 15mm (0.59”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Part Number T456CFNF1R
      Description Right Angle Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 38mm (1.50”)
      Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
      Minimum Convex Surface Diameter F: 4mm (0.16")
      N: 26mm (1.02")
      Minimum Concave Surface Radius 12.5mm (0.49")
      Part Number T456CFNF1P
      Description PINIP™ Integral Probe
      Minimum Headroom 180mm (7.09”)
      Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
      Minimum Convex Surface Diameter F: 4mm (0.16")
      N: 26mm (1.02")
      Minimum Concave Surface Radius 65mm (2.56")
      Scale 2: Range : 0-5mm (0-200mils)
      Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil)
      Ranged 0-5mm (0-200mils)
      Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
      10μm: 1-5mm (1.0mil: 50-200mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CF2S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 89mm (3.50”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF2U
      Description Scan Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 90mm (3.54”)
      Minimum Sample Diameterb 15mm (0.59”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Part Number T456CF2R
      Description 90° Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 32mm (1.26”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF2ARM
      Description Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF2T
      Description Telescopic Probe
      Probe Length: 56-122cm (22-48”)c
      Minimum Headroom 36mm (1.42”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 25mm (0.98")
      Part Number T456CF2B
      Description Soft Coating Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 89mm (3.50”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Part Number T456CF2SW
      Description Waterproof Probe - 1m (3’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2SW-5
      Description Waterproof Probe - 5m (15’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2SW-15
      Description Waterproof Probe - 15m (45’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2SW-30
      Description Waterproof Probe - 30m (98’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2SW-50
      Description Waterproof Probe - 50m (164’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2SW-75
      Description Waterproof Probe - 75m (250’) cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 138mm (5.43”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF2P
      Description PINIP™ Integral Probe
      Minimum Headroom 174mm (6.85”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 60mm (2.36")
      Part Number T456CF2PHT
      Description Hi-Temperature PINIP™
      Minimum Headroom 174mm (6.85”)
      Minimum Sample Diameterb 8mm (0.32”)
      Minimum Convex Surface Diameter 4mm (0.16")
      Minimum Concave Surface Radius 60mm (2.36")
       
      Non-Ferrous (N)
      Part Number T456CN2S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 88mm (3.46”)
      Minimum Sample Diameterb 14mm (0.55”)
      Minimum Convex Surface Diameter 100mm (3.97")
      Minimum Concave Surface Radius 150mm (5.90")
      Part Number T456CN2P
      Description PINIP™ Integral Probe
      Minimum Headroom 185mm (7.28")
      Minimum Sample Diameterb 14mm (0.55”)
      Minimum Convex Surface Diameter 100mm (3.97")
      Minimum Concave Surface Radius 150mm (5.90")
      Scale 3: Range : 0-13mm (0-500mils)
      Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils)
      Ranged 0-13mm (0-500mils)
      Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
      10μm: 2-13mm (1.0mil: 100-500mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CF3S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 102mm (4.02”)
      Minimum Sample Diameterb 14mm (0.55”)
      Minimum Convex Surface Diameter 15mm (0.59")
      Minimum Concave Surface Radius 40mm (1.98")
      Part Number T456CF3P
      Description PINIP™ Integral Probe
      Minimum Headroom 184mm (7.24”)
      Minimum Sample Diameterb 14mm (0.55”)
      Minimum Convex Surface Diameter 15mm (0.59")
      Minimum Concave Surface Radius 45mm (1.77")
       
      Non-Ferrous (N)
      Part Number T456CN3S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 170mm (6.69”)
      Minimum Sample Diameterb 35mm (1.38”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Scale FM7: Range : 0.60-3.8mm (25-150mils)
      Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils)
      Ranged 0.60-3.8mm (25-150mils)
      Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
      10μm: 1-3.8mm (1.0mil: 39.4-150mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CFM7R45A
      Description 45° Angle Mini Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 20mm (0.79”)
      Minimum Sample Diameterb 6.5 mm (0.26’’)
      Minimum Convex Surface Diameter -
      Minimum Concave Surface Radius -
      Scale 6: Range : F: 0-25mm (F: 0-980mils)
      N: 0-30mm (N: 0-1200mils)
      Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
      Ranged F: 0-25mm (F: 0-980mils)
      N: 0-30mm (N: 0-1200mils)
      Resolution 10μm: 0-2mm (1mil: 0-100mils)
      100μm: 2-30mm (10mils: 100-1200mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CF6S
      Description Straight Probe
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 150mm (5.90”)
      Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2)
      Minimum Convex Surface Diameter 35mm (1.40")
      Minimum Concave Surface Radius 170mm (6.70")
      Part Number T456CF6ARM
      Description Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 190mm (7.48”)
      Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2)
      Minimum Convex Surface Diameter 35mm (1.40")
      Minimum Concave Surface Radius 170mm (6.70")
       
      Non-Ferrous (N)
      Straight Probe
      Probe Length: 45mm (1.77”)c
      T456CN6S
      Minimum Headroom 160mm (6.30”)
      Minimum Sample Diameterb 58mm (2.29”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Straight Probe - armoured cable
      Probe Length: 45mm (1.77”)c
      T456CN6ARM
      Minimum Headroom 200mm (7.87")
      Minimum Sample Diameterb 58mm (2.29”)
      Minimum Convex Surface Diameter Flat Surface
      Minimum Concave Surface Radius Flat Surface
      Scale 7: Range : 0-31mm (0-1220mils)
      Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
      Ranged 0-31mm (0-1220mils)
      Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
      100μm: 2-31mm (10mils: 100-1220mils)
      Certificate
      Certificate supplied as standard
      Ferrous (F)
      Part Number T456CF7ARM
      Description Straight Probe armoured cable
      Probe Length: 45mm (1.77”)c
      Minimum Headroom 200mm (7.87")
      Minimum Sample Diameterb 55 x 55mm2 (2.17 x 2.17 inch2)
      Minimum Convex Surface Diameter 40mm (1.58")
      Minimum Concave Surface Radius 170mm (6.70")
      a. Whichever is the greater
      b. FNF (F): FNF probe in F Mode / FNF (N): FNF probe in N
      c. Probe length is measured from X to Y
      d. Excluding Scan Probe end cap
      e. Scan Probe accuracy is ±3% or ±0.02mm (0.8mil) with cap fitted, ±1-3% or ±0.02mm (0.8mil) without cap, when calibrated using a sample of the uncoated substrate
      Test Certificate supplied as standard.
      Elcometer 456 Probes are covered by a one-year warranty
  • Downloads
    • Downloads
      • Elcometer 456 Coating Thickness Gauge Full Instruction Manual

      • Elcometer 456 Ultra/Scan Probe Instruction Manual

      • Elcometer 456 Waterproof Probe Instruction Manual

      • Elcometer 456 Coating Thickness Gauge Datasheet

  • Part Numbers
    • Part Numbers
      Elcometer 456 Coating Thickness Gauge Probe Range
      • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 300mm (11.80”)
        • Minimum Headroom: 18mm (0.71”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3R45D
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 300mm (11.80”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3R90D
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3R90C
      • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 6mm (0.24”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3---C
      • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3R45A
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3R90A
      • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 6mm (0.24”)
        • Minimum Sample Diameter: 3mm (0.12”)
        • Part Number : T456CFM3---A
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 400mm (15.70”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM3R90E
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM3R90C
      • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 6mm (0.24”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM3---C
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM3R90A
      • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 6mm (0.24”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM3---A
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous - Graphite (N)
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 400mm (15.70”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNMG3R90E
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous - Graphite (N)
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNMG3R90C
      • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
        • Substrate Probe: Non-Ferrous - Graphite (N)
        • Range: 0-500μm, 0-20mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNMG3R90A
      • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale FM7
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0.60-3.8mm, 25-150mils
        • Accuracy: ±7.5% or ±114μm, ±7,5% or ±4,5mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 20mm (0.79”)
        • Minimum Sample Diameter: 6.5 mm (0.26’’)
        • Part Number : T456CFM7R45A
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 85mm (3.35”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CF1S
      • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 86mm (3.38”)
        • Minimum Sample Diameter: 15mm (0.59”)
        • Part Number : T456CF1U
      • Elcometer 456 Coating Thickness Gauge Scan Probe Armoured - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 140mm (5.51”)
        • Minimum Sample Diameter: 15mm (0.59”)
        • Part Number : T456CF1UARM
      • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 28mm (1.10”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CF1R
      • Elcometer 456 Coating Thickness Gauge 90° Mini Probe - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CFM5R90A
      • Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CFME5R90A
      • Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed, 2m cable - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CFME5R90A-2
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Minimum Headroom: 170mm (6.69”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CF1P
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 85mm (3.35”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CN1S
      • Elcometer 456 Coating Thickness Gauge Straight Probe sealed - Scale 1
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 85mm (3.35”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CF1E
      • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 28mm (1.10”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CN1R
      • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM5R90A
      • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 150mm (5.90”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM5R90C
      • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 400mm (15.70”)
        • Minimum Headroom: 16mm (0.63”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CNM5R90E
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Minimum Headroom: 180mm (7.09”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CN1P
      • Elcometer 456 Coating Thickness Gauge Anodiser Probe - Scale 1
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 100mm (3.94”)
        • Minimum Sample Diameter: 4mm (0.16”)
        • Part Number : T456CN1AS
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
        • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 88mm (3.46”)
        • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
        • Part Number : T456CFNF1S
      • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
        • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 89mm (3.50”)
        • Minimum Sample Diameter: 15mm (0.59”)
        • Part Number : T456CFNF1U
      • Elcometer 456 Coating Thickness Gauge Right Angle Probe - Scale 1
        • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 38mm (1.50”)
        • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
        • Part Number : T456CFNF1R
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
        • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Minimum Headroom: 180mm (7.09”)
        • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
        • Part Number : T456CFNF1P
      • Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 1
        • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
        • Range: 0-1,500μm, 0-60mils
        • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 185mm (7.28")
        • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
        • Part Number : T456CFNF1ARM
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 89mm (3.50”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2S
      • Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2ARM
      • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 90mm (3.54”)
        • Minimum Sample Diameter: 15mm (0.59”)
        • Part Number : T456CF2U
      • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 32mm (1.26”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2R
      • Elcometer 456 Coating Thickness Gauge Telescopic Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 56-122cm (22-48”)
        • Minimum Headroom: 36mm (1.42”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2T
      • Elcometer 456 Coating Thickness Gauge Soft Coating Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 89mm (3.50”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2B
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 1m (3’) cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 5m (15") cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW-5
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 15m (45") cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW-15
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 30m (98") cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW-30
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 50m (164") cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW-50
      • Elcometer 456 Coating Thickness Gauge Waterproof Probe 75m (250") cable - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 138mm (5.43”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2SW-75
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Minimum Headroom: 174mm (6.85”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2P
      • Elcometer 456 Coating Thickness Gauge Hi-Temperature PINIP™ - Scale 2
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Minimum Headroom: 174mm (6.85”)
        • Minimum Sample Diameter: 8mm (0.32”)
        • Part Number : T456CF2PHT
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 88mm (3.46”)
        • Minimum Sample Diameter: 14mm (0.55”)
        • Part Number : T456CN2S
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-5mm, 0-200mils
        • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
        • Minimum Headroom: 185mm (7.28")
        • Minimum Sample Diameter: 14mm (0.55”)
        • Part Number : T456CN2P
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-13mm, 0-500mils
        • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 102mm (4.02”)
        • Minimum Sample Diameter: 14mm (0.55”)
        • Part Number : T456CF3S
      • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 3
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-13mm, 0-500mils
        • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
        • Minimum Headroom: 184mm (7.24”)
        • Minimum Sample Diameter: 14mm (0.55”)
        • Part Number : T456CF3P
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-13mm, 0-500mils
        • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 170mm (6.69”)
        • Minimum Sample Diameter: 35mm (1.38”)
        • Part Number : T456CN3S
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
        • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 150mm (5.90”)
        • Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
        • Part Number : T456CF6S
      • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
        • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 190mm (7.48”)
        • Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
        • Part Number : T456CF6ARM
      • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
        • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 160mm (6.30”)
        • Minimum Sample Diameter: 58mm (2.29”)
        • Part Number : T456CN6S
      • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
        • Substrate Probe: Non-Ferrous (N) Probes
        • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
        • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 200mm (7.87")
        • Minimum Sample Diameter: 58mm (2.29”)
        • Part Number : T456CN6ARM
      • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 7
        • Substrate Probe: Ferrous (F) Probes
        • Range: 0-31mm, 0-1220mils
        • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
        • Probe Length: 45mm (1.77”)
        • Minimum Headroom: 200mm (7.87")
        • Minimum Sample Diameter: 55 x 55mm2 (2.17 x 2.17 inch2)
        • Part Number : T456CF7ARM
  • Accessories
    • Accessories
      Elcometer 456 Coating Thickness Gauge Probe Range
      • Part Number: T9997766-
      • Part Number: T99913225
      • Part Number: T9997381-
      • Part Number: T99913133
      • Part Number: T456C23956
      • Part Number: T456C29050

Elcometer 456 Coating Thickness Gauge Probe Range

  • Protective Coatings
  • Industrial Finishing
456-probesIntro-Images
Elcometer 456 Probe Range

All Elcometer 456 Coating Thickness Gauge probes are fully interchangeable and are available in a number of designs and scale ranges to meet your specific application.

Telescopic Probes for hard to reach places

Ferrous Probes (F)

  • Ferrous probes measure non-magnetic coatings on ferromagnetic substrates
  • Elcometer 456 ferrous gauges accept any ferrous probe
Non-Ferrous Probes

Non-Ferrous Probes (N)

  • Non-ferrous probes measure non-conductive coatings on non-ferrous metal substrates
  • Elcometer 456 non-ferrous gauges accept any non-ferrous probe
Dual FNF Probes

Dual Probes (FNF)

  • Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection
  • Elcometer 456 FNF gauges accept all ferrous, non-ferrous and dual FNF probes
High Temperature PINIP Probe

High Temperature

  • Elcometer probes have a maximum operating temperature of 80°C (176°F)*
  • Separate ferrous probes have a maximum operating temperature of 150°C (300°F)*
  • Hi-Temperature PINIP™ has a maximum operating temperature of 250°C (480°F)*
*The stated temperature is the substrate temperature, and the duty cycle of the probe must be reduced to ensure a minimal temperature build-up within the probe.

Summary

Elcometer 456 Coating Thickness Gauge Probe Range

Ferrous coating thickness gauge probes measure non magnetic coatings on ferro-magnetic substrates. Elcometer 456 coating thickness ferrous gauges accept any ferrous probe.

Non-ferrous coating thickness gauge probes measure non conductive coatings on non-ferrous metal substrates and Elcometer 456 non-ferrous gauges accept any non-ferrous probe.

Dual FNF probes measure both ferrous and non-ferrous applications with automatic substrate detection. Elcometer 456 FNF coating thickness gauges accept all ferrous, non-ferrous and dual FNF probes.

Downloads
  • Elcometer 456 Coating Thickness Gauge Full Instruction Manual

  • Elcometer 456 Ultra/Scan Probe Instruction Manual

  • Elcometer 456 Waterproof Probe Instruction Manual

  • Elcometer 456 Coating Thickness Gauge Datasheet

Key Features

Elcometer 456 Coating Thickness Gauge Probe Range

Straight Probes

Standard Straight Probe

Standard Straight Probe
Standard probes measure coatings on both flat and curved surfaces.

Anodising ProbeAnodising Probe
Chemical resistant & washable - ideal for the anodising environment.

Mini ProbeMini Probe
Mini probes are ideal for harder to reach areas and edges.

Waterproof ProbeWaterproof Probe
Sealed for use underwater at depth, even in diving gloves.

Soft Coatings ProbeSoft Coating Probe
Large surface area probes are for soft materials (HVCA approved).

Thick Coatings ProbeThick Coatings Probe
Ideal for measuring coatings up to 31mm thick.

Scan Probes

Standard Scan ProbeStandard Scan Probe
Rapidly scan large surface areas without damaging the probe or the coating.

Ball Bearing Scan ProbeBall Bearing Scan Probe*
Clip on adaptors for large coated structures, abrasive coatings and pre-construction primers.

Angled Probes

Right Angle ProbeRight Angle Probe
Take readings in areas with restricted clearance.

Mini Right Angle ProbeMini Right Angle Probe
For measuring coatings on edges, narrow pipes or small surface areas.

Telescopic ProbeTelescopic Probe
Extending probes for hard to reach areas.

45° Angle Probe45° Angle Probe
Measure difficult to access or complex areas.

Plug In Integral Probes (PINIP™)

PINIP ProbePINIP™ Integral Probe
Transforms a separate gauge into an integral gauge, ideal for single-handed use.

High Temperture PINIP ProbeHi-Temperature PINIP™
Measure coatings on ferrous substrates up to 250°C (480°F).

Armoured Cable Probes

Armoured ProbeF / FNF Armoured Probe
Reinforced heavy duty cables reduce the risk of cable damage.

*UK Patent Number: 2571577

Technical Specification
Elcometer 456 Coating Thickness Gauge Probe Range
Scale 0.5: Range : 0-500μm (0-20mils)
Accuracya (±1-3% or ±0.1mil)
Range 0-500μm (0-20mils)
Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Mini Probe
Probe Length: 45mm (1.77”)c
T456CFM3---A 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
T456CFM3R90A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
45° Angle Mini Probe
Probe Length: 45mm (1.77”)c
T456CFM3R45A 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
Straight Mini Probe
Probe Length: 150mm (5.90”)c
T456CFM3---C 6mm (0.24”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
T456CFM3R90C 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
45° Angle Mini Probe
Probe Length: 300mm (11.80”)c
T456CFM3R45D 18mm (0.71”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
Right Angle Mini Probe
Probe Length: 300mm (11.80”)c
T456CFM3R90D 16mm (0.63”) 3mm (0.12”) 1.9mm (0.07") 6.5mm (0.26")
 
Non-Ferrous (N)
Straight Mini Probe
Probe Length: 45mm (1.77”)c
T456CNM3---A 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
T456CNM3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Straight Mini Probe
Probe Length: 150mm (5.90”)c
T456CNM3---C 6mm (0.24”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
T456CNM3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Right Angle Mini Probe
Probe Length: 400mm (15.70”)c
T456CNM3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
 
Non-Ferrous - Graphite (N)
Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
T456CNMG3R90A 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
T456CNMG3R90C 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Right Angle Mini Probe
Probe Length: 400mm (15.70”)c
T456CNMG3R90E 16mm (0.63”) 4mm (0.16”) 6mm (0.24") 8.5mm (0.33")
Scale 1: Range : 0-1500μm (0-60mils)
Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil)
Ranged 0-1500μm (0-60mils)
Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CF1S 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
Straight Probe - sealed
Probe Length: 45mm (1.77”)c
T456CF1E 85mm (3.35”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
Scan Probe
Probe Length: 45mm (1.77”)c
T456CF1U 86mm (3.38”) 15mm (0.59”) Flat Surface Flat Surface
Scan Probe - armoured
Probe Length: 45mm (1.77”)c
T456CF1UARM 140mm (5.51”) 15mm (0.59”) Flat Surface Flat Surface
90° Probe
Probe Length: 45mm (1.77”)c
T456CF1R 28mm (1.10”) 4mm (0.16”) 4mm (0.16") 25mm (0.98")
90° Mini Probe
Probe Length: 45mm (1.77”)c
T456CFM5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
90° Mini Probe - sealed
Probe Length: 45mm (1.77”)c
T456CFME5R90A 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)c
T456CFME5R90A-2 16mm (0.63”) 4mm (0.16”) 3mm (0.12") 6.5mm (0.26")
PINIP™ Integral Probe T456CF1P 170mm (6.69”) 4mm (0.16”) 4mm (0.16") 60mm (2.36")
 
Non-Ferrous (N)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CN1S 85mm (3.35”) 4mm (0.16”) 10mm (0.39") 10mm (0.39")
90° Probe
Probe Length: 45mm (1.77”)c
T456CN1R 28mm (1.10”) 4mm (0.16”) 10mm (0.39") 14mm (0.55")
Mini 90° Probe
Probe Length: 45mm (1.77”)c
T456CNM5R90A 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
Mini 90°Probe
Probe Length: 150mm (5.90”)c
T456CNM5R90C 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
Mini 90° Probe
Probe Length: 400mm (15.7”)c
T456CNM5R90E 16mm (0.63”) 4mm (0.16”) 10mm (0.39") 8.5mm (0.33")
Anodiser Probe
Probe Length: 45mm (1.77”)c
T456CN1AS 100mm (3.94”) 4mm (0.16”) 10mm (0.39") 14mm (0.55")
PINIP™ Integral Probe T456CN1P 180mm (7.09”) 4mm (0.16”) 10mm (0.39") 50mm (1.97")
 
Ferrous & Non-Ferrous (FNF)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CFNF1S 88mm (3.46”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")
12.5mm (0.49")
Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
T456CFNF1ARM 185mm (7.28") F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")
12.5mm (0.49")
Scan Probe
Probe Length: 45mm (1.77”)c
T456CFNF1U 89mm (3.50”) 15mm (0.59”) Flat Surface Flat Surface
Right Angle Probe
Probe Length: 45mm (1.77”)c
T456CFNF1R 38mm (1.50”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")
12.5mm (0.49")
PINIP™ Integral Probe T456CFNF1P 180mm (7.09”) F: 4mm (0.16”), N: 6mm (0.24”) F: 4mm (0.16")
N: 26mm (1.02")
65mm (2.56")
Scale 2: Range : 0-5mm (0-200mils)
Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil)
Ranged 0-5mm (0-200mils)
Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CF2S 89mm (3.50”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
Scan Probe
Probe Length: 45mm (1.77”)c
T456CF2U 90mm (3.54”) 15mm (0.59”) Flat Surface Flat Surface
90° Probe
Probe Length: 45mm (1.77”)c
T456CF2R 32mm (1.26”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
T456CF2ARM 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
Telescopic Probe
Probe Length: 56-122cm (22-48”)c
T456CF2T 36mm (1.42”) 8mm (0.32”) 4mm (0.16") 25mm (0.98")
Soft Coating Probe
Probe Length: 45mm (1.77”)c
T456CF2B 89mm (3.50”) 8mm (0.32”) Flat Surface Flat Surface
Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW-5 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW-15 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW-30 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW-50 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)c
T456CF2SW-75 138mm (5.43”) 8mm (0.32”) 4mm (0.16") 40mm (1.98")
PINIP™ Integral Probe T456CF2P 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36")
Hi-Temperature PINIP™ T456CF2PHT 174mm (6.85”) 8mm (0.32”) 4mm (0.16") 60mm (2.36")
 
Non-Ferrous (N)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CN2S 88mm (3.46”) 14mm (0.55”) 100mm (3.97") 150mm (5.90")
PINIP™ Integral Probe T456CN2P 185mm (7.28") 14mm (0.55”) 100mm (3.97") 150mm (5.90")
Scale 3: Range : 0-13mm (0-500mils)
Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils)
Ranged 0-13mm (0-500mils)
Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CF3S 102mm (4.02”) 14mm (0.55”) 15mm (0.59") 40mm (1.98")
PINIP™ Integral Probe T456CF3P 184mm (7.24”) 14mm (0.55”) 15mm (0.59") 45mm (1.77")
 
Non-Ferrous (N)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CN3S 170mm (6.69”) 35mm (1.38”) Flat Surface Flat Surface
Scale FM7: Range: 0.60-3.8mm (25-150mils)
Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils)
Ranged 0.60-3.8mm (25-150mils)
Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
45° Angle Mini Probe
Probe Length: 45mm (1.77”)c
T456CFM7R45A 20mm (0.79”) 6.5 mm (0.26’’) - -
Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)
Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)
Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CF6S 150mm (5.90”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70")
Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
T456CF6ARM 190mm (7.48”) 51 x 51mm2 (2.17 x 2.17 inch2) 35mm (1.40") 170mm (6.70")
 
Non-Ferrous (N)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CN6S 160mm (6.30”) 58mm (2.29”) Flat Surface Flat Surface
Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
T456CN6ARM 200mm (7.87") 58mm (2.29”) Flat Surface Flat Surface
Scale 7: Range : 0-31mm (0-1220mils)
Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
Ranged 0-31mm (0-1220mils)
Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)
Certificate
Certificate supplied as standard
DescriptionPart NumberMinimum HeadroomMinimum Sample DiameterbMinimum Convex Surface DiameterMinimum Concave Surface Radius
Ferrous (F)
Straight Probe armoured cable
Probe Length: 45mm (1.77”)c
T456CF7ARM 200mm (7.87") 55 x 55mm2 (2.17 x 2.17 inch2) 40mm (1.58") 170mm (6.70")
Scale 0.5: Range : 0-500μm (0-20mils)
Accuracya (±1-3% or ±0.1mil)
Range 0-500μm (0-20mils)
Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-500μm (0.1mil: 5-20mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CFM3---A
Description Straight Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 6mm (0.24”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3R90A
Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3R45A
Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3---C
Description Straight Mini Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 6mm (0.24”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3R90C
Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3R45D
Description 45° Angle Mini Probe
Probe Length: 300mm (11.80”)c
Minimum Headroom 18mm (0.71”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFM3R90D
Description Right Angle Mini Probe
Probe Length: 300mm (11.80”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 3mm (0.12”)
Minimum Convex Surface Diameter 1.9mm (0.07")
Minimum Concave Surface Radius 6.5mm (0.26")
 
Non-Ferrous (N)
Part Number T456CNM3---A
Description Straight Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 6mm (0.24”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM3R90A
Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM3---C
Description Straight Mini Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 6mm (0.24”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM3R90C
Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM3R90E
Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
 
Non-Ferrous - Graphite (N)
Part Number T456CNMG3R90A
Description Right Angle Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNMG3R90C
Description Right Angle Mini Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNMG3R90E
Description Right Angle Mini Probe
Probe Length: 400mm (15.70”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 6mm (0.24")
Minimum Concave Surface Radius 8.5mm (0.33")
Scale 1: Range : 0-1500μm (0-60mils)
Accuracyae ±1-3% or ±2.5μm (±1-3% or ±0.1mil)
Ranged 0-1500μm (0-60mils)
Resolution 0.1μm: 0-100μm (0.01mil: 0-5mils)
1μm: 100-1500μm (0.1mil: 5-60mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CF1S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF1E
Description Straight Probe - sealed
Probe Length: 45mm (1.77”)c
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF1U
Description Scan Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 86mm (3.38”)
Minimum Sample Diameterb 15mm (0.59”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Part Number T456CF1UARM
Description Scan Probe - armoured
Probe Length: 45mm (1.77”)c
Minimum Headroom 140mm (5.51”)
Minimum Sample Diameterb 15mm (0.59”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Part Number T456CF1R
Description 90° Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 28mm (1.10”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CFM5R90A
Description 90° Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 3mm (0.12")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFME5R90A
Description 90° Mini Probe - sealed
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 3mm (0.12")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CFME5R90A-2
Description 90° Mini Probe - sealed, 2m cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 3mm (0.12")
Minimum Concave Surface Radius 6.5mm (0.26")
Part Number T456CF1P
Description PINIP™ Integral Probe
Minimum Headroom 170mm (6.69”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 60mm (2.36")
 
Non-Ferrous (N)
Part Number T456CN1S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 85mm (3.35”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 10mm (0.39")
Part Number T456CN1R
Description 90° Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 28mm (1.10”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 14mm (0.55")
Part Number T456CNM5R90A
Description Mini 90° Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM5R90C
Description Mini 90°Probe
Probe Length: 150mm (5.90”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CNM5R90E
Description Mini 90° Probe
Probe Length: 400mm (15.7”)c
Minimum Headroom 16mm (0.63”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 8.5mm (0.33")
Part Number T456CN1AS
Description Anodiser Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 100mm (3.94”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 14mm (0.55")
Part Number T456CN1P
Description PINIP™ Integral Probe
Minimum Headroom 180mm (7.09”)
Minimum Sample Diameterb 4mm (0.16”)
Minimum Convex Surface Diameter 10mm (0.39")
Minimum Concave Surface Radius 50mm (1.97")
 
Ferrous & Non-Ferrous (FNF)
Part Number T456CFNF1S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 88mm (3.46”)
Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")
Minimum Concave Surface Radius 12.5mm (0.49")
Part Number T456CFNF1ARM
Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 185mm (7.28")
Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")
Minimum Concave Surface Radius 12.5mm (0.49")
Part Number T456CFNF1U
Description Scan Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 89mm (3.50”)
Minimum Sample Diameterb 15mm (0.59”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Part Number T456CFNF1R
Description Right Angle Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 38mm (1.50”)
Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")
Minimum Concave Surface Radius 12.5mm (0.49")
Part Number T456CFNF1P
Description PINIP™ Integral Probe
Minimum Headroom 180mm (7.09”)
Minimum Sample Diameterb F: 4mm (0.16”), N: 6mm (0.24”)
Minimum Convex Surface Diameter F: 4mm (0.16")
N: 26mm (1.02")
Minimum Concave Surface Radius 65mm (2.56")
Scale 2: Range : 0-5mm (0-200mils)
Accuracyae ±1-3% or ±20μm (±1-3% or ±1.0mil)
Ranged 0-5mm (0-200mils)
Resolution 1μm: 0-1mm (0.1mil: 0-50mils)
10μm: 1-5mm (1.0mil: 50-200mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CF2S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 89mm (3.50”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF2U
Description Scan Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 90mm (3.54”)
Minimum Sample Diameterb 15mm (0.59”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Part Number T456CF2R
Description 90° Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 32mm (1.26”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF2ARM
Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF2T
Description Telescopic Probe
Probe Length: 56-122cm (22-48”)c
Minimum Headroom 36mm (1.42”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 25mm (0.98")
Part Number T456CF2B
Description Soft Coating Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 89mm (3.50”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Part Number T456CF2SW
Description Waterproof Probe - 1m (3’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2SW-5
Description Waterproof Probe - 5m (15’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2SW-15
Description Waterproof Probe - 15m (45’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2SW-30
Description Waterproof Probe - 30m (98’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2SW-50
Description Waterproof Probe - 50m (164’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2SW-75
Description Waterproof Probe - 75m (250’) cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 138mm (5.43”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF2P
Description PINIP™ Integral Probe
Minimum Headroom 174mm (6.85”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 60mm (2.36")
Part Number T456CF2PHT
Description Hi-Temperature PINIP™
Minimum Headroom 174mm (6.85”)
Minimum Sample Diameterb 8mm (0.32”)
Minimum Convex Surface Diameter 4mm (0.16")
Minimum Concave Surface Radius 60mm (2.36")
 
Non-Ferrous (N)
Part Number T456CN2S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 88mm (3.46”)
Minimum Sample Diameterb 14mm (0.55”)
Minimum Convex Surface Diameter 100mm (3.97")
Minimum Concave Surface Radius 150mm (5.90")
Part Number T456CN2P
Description PINIP™ Integral Probe
Minimum Headroom 185mm (7.28")
Minimum Sample Diameterb 14mm (0.55”)
Minimum Convex Surface Diameter 100mm (3.97")
Minimum Concave Surface Radius 150mm (5.90")
Scale 3: Range : 0-13mm (0-500mils)
Accuracya ±1-3% or ±50μm (±1-3% or ±2.0mils)
Ranged 0-13mm (0-500mils)
Resolution 1μm: 0-2mm (0.1mil: 0-100mils)
10μm: 2-13mm (1.0mil: 100-500mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CF3S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 102mm (4.02”)
Minimum Sample Diameterb 14mm (0.55”)
Minimum Convex Surface Diameter 15mm (0.59")
Minimum Concave Surface Radius 40mm (1.98")
Part Number T456CF3P
Description PINIP™ Integral Probe
Minimum Headroom 184mm (7.24”)
Minimum Sample Diameterb 14mm (0.55”)
Minimum Convex Surface Diameter 15mm (0.59")
Minimum Concave Surface Radius 45mm (1.77")
 
Non-Ferrous (N)
Part Number T456CN3S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 170mm (6.69”)
Minimum Sample Diameterb 35mm (1.38”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Scale FM7: Range : 0.60-3.8mm (25-150mils)
Accuracya ±7.5% or ±114μm (±7.5% or ±4.5mils)
Ranged 0.60-3.8mm (25-150mils)
Resolution 1μm: 0-1mm (0.1mil: 0-139.3mils)
10μm: 1-3.8mm (1.0mil: 39.4-150mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CFM7R45A
Description 45° Angle Mini Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 20mm (0.79”)
Minimum Sample Diameterb 6.5 mm (0.26’’)
Minimum Convex Surface Diameter -
Minimum Concave Surface Radius -
Scale 6: Range : F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)
Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
Ranged F: 0-25mm (F: 0-980mils)
N: 0-30mm (N: 0-1200mils)
Resolution 10μm: 0-2mm (1mil: 0-100mils)
100μm: 2-30mm (10mils: 100-1200mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CF6S
Description Straight Probe
Probe Length: 45mm (1.77”)c
Minimum Headroom 150mm (5.90”)
Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2)
Minimum Convex Surface Diameter 35mm (1.40")
Minimum Concave Surface Radius 170mm (6.70")
Part Number T456CF6ARM
Description Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 190mm (7.48”)
Minimum Sample Diameterb 51 x 51mm2 (2.17 x 2.17 inch2)
Minimum Convex Surface Diameter 35mm (1.40")
Minimum Concave Surface Radius 170mm (6.70")
 
Non-Ferrous (N)
Straight Probe
Probe Length: 45mm (1.77”)c
T456CN6S
Minimum Headroom 160mm (6.30”)
Minimum Sample Diameterb 58mm (2.29”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Straight Probe - armoured cable
Probe Length: 45mm (1.77”)c
T456CN6ARM
Minimum Headroom 200mm (7.87")
Minimum Sample Diameterb 58mm (2.29”)
Minimum Convex Surface Diameter Flat Surface
Minimum Concave Surface Radius Flat Surface
Scale 7: Range : 0-31mm (0-1220mils)
Accuracya ±1-3% or ±100μm (±1-3% or ±4.0mils)
Ranged 0-31mm (0-1220mils)
Resolution 10μm: 0-2mm (1.0mil: 0-100mils)
100μm: 2-31mm (10mils: 100-1220mils)
Certificate
Certificate supplied as standard
Ferrous (F)
Part Number T456CF7ARM
Description Straight Probe armoured cable
Probe Length: 45mm (1.77”)c
Minimum Headroom 200mm (7.87")
Minimum Sample Diameterb 55 x 55mm2 (2.17 x 2.17 inch2)
Minimum Convex Surface Diameter 40mm (1.58")
Minimum Concave Surface Radius 170mm (6.70")
a. Whichever is the greater
b. FNF (F): FNF probe in F Mode / FNF (N): FNF probe in N
c. Probe length is measured from X to Y
d. Excluding Scan Probe end cap
e. Scan Probe accuracy is ±3% or ±0.02mm (0.8mil) with cap fitted, ±1-3% or ±0.02mm (0.8mil) without cap, when calibrated using a sample of the uncoated substrate
Test Certificate supplied as standard.
Elcometer 456 Probes are covered by a one-year warranty
Part Numbers
Elcometer 456 Coating Thickness Gauge Probe Range
  • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 300mm (11.80”)
    • Minimum Headroom: 18mm (0.71”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3R45D
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 300mm (11.80”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3R90D
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3R90C
  • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 6mm (0.24”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3---C
  • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3R45A
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3R90A
  • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 6mm (0.24”)
    • Minimum Sample Diameter: 3mm (0.12”)
    • Part Number : T456CFM3---A
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 400mm (15.70”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM3R90E
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM3R90C
  • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 6mm (0.24”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM3---C
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM3R90A
  • Elcometer 456 Coating Thickness Gauge Straight Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 6mm (0.24”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM3---A
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous - Graphite (N)
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 400mm (15.70”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNMG3R90E
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous - Graphite (N)
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNMG3R90C
  • Elcometer 456 Coating Thickness Gauge Right Angle Mini Probe - Scale 0.5
    • Substrate Probe: Non-Ferrous - Graphite (N)
    • Range: 0-500μm, 0-20mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNMG3R90A
  • Elcometer 456 Coating Thickness Gauge 45° Angle Mini Probe - Scale FM7
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0.60-3.8mm, 25-150mils
    • Accuracy: ±7.5% or ±114μm, ±7,5% or ±4,5mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 20mm (0.79”)
    • Minimum Sample Diameter: 6.5 mm (0.26’’)
    • Part Number : T456CFM7R45A
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 85mm (3.35”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CF1S
  • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 86mm (3.38”)
    • Minimum Sample Diameter: 15mm (0.59”)
    • Part Number : T456CF1U
  • Elcometer 456 Coating Thickness Gauge Scan Probe Armoured - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 140mm (5.51”)
    • Minimum Sample Diameter: 15mm (0.59”)
    • Part Number : T456CF1UARM
  • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 28mm (1.10”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CF1R
  • Elcometer 456 Coating Thickness Gauge 90° Mini Probe - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CFM5R90A
  • Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CFME5R90A
  • Elcometer 456 Coating Thickness Gauge 90° Mini Probe sealed, 2m cable - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CFME5R90A-2
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Minimum Headroom: 170mm (6.69”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CF1P
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 85mm (3.35”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CN1S
  • Elcometer 456 Coating Thickness Gauge Straight Probe sealed - Scale 1
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 85mm (3.35”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CF1E
  • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 28mm (1.10”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CN1R
  • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM5R90A
  • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 150mm (5.90”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM5R90C
  • Elcometer 456 Coating Thickness Gauge Mini 90° Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 400mm (15.70”)
    • Minimum Headroom: 16mm (0.63”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CNM5R90E
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Minimum Headroom: 180mm (7.09”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CN1P
  • Elcometer 456 Coating Thickness Gauge Anodiser Probe - Scale 1
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 100mm (3.94”)
    • Minimum Sample Diameter: 4mm (0.16”)
    • Part Number : T456CN1AS
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 1
    • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 88mm (3.46”)
    • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
    • Part Number : T456CFNF1S
  • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 1
    • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 89mm (3.50”)
    • Minimum Sample Diameter: 15mm (0.59”)
    • Part Number : T456CFNF1U
  • Elcometer 456 Coating Thickness Gauge Right Angle Probe - Scale 1
    • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 38mm (1.50”)
    • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
    • Part Number : T456CFNF1R
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 1
    • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Minimum Headroom: 180mm (7.09”)
    • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
    • Part Number : T456CFNF1P
  • Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 1
    • Substrate Probe: Ferrous & Non-Ferrous (FNF) Probes
    • Range: 0-1,500μm, 0-60mils
    • Accuracy: ±1-3% or ±2.5μm, ±1-3% or ±0.1mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 185mm (7.28")
    • Minimum Sample Diameter: F: 4mm (0.16”), N: 6mm (0.24”)
    • Part Number : T456CFNF1ARM
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 89mm (3.50”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2S
  • Elcometer 456 Coating Thickness Gauge Straight Probe Armoured Cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2ARM
  • Elcometer 456 Coating Thickness Gauge Scan Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 90mm (3.54”)
    • Minimum Sample Diameter: 15mm (0.59”)
    • Part Number : T456CF2U
  • Elcometer 456 Coating Thickness Gauge 90° Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 32mm (1.26”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2R
  • Elcometer 456 Coating Thickness Gauge Telescopic Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 56-122cm (22-48”)
    • Minimum Headroom: 36mm (1.42”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2T
  • Elcometer 456 Coating Thickness Gauge Soft Coating Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 89mm (3.50”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2B
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 1m (3’) cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 5m (15") cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW-5
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 15m (45") cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW-15
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 30m (98") cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW-30
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 50m (164") cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW-50
  • Elcometer 456 Coating Thickness Gauge Waterproof Probe 75m (250") cable - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 138mm (5.43”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2SW-75
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Minimum Headroom: 174mm (6.85”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2P
  • Elcometer 456 Coating Thickness Gauge Hi-Temperature PINIP™ - Scale 2
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Minimum Headroom: 174mm (6.85”)
    • Minimum Sample Diameter: 8mm (0.32”)
    • Part Number : T456CF2PHT
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 2
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 88mm (3.46”)
    • Minimum Sample Diameter: 14mm (0.55”)
    • Part Number : T456CN2S
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 2
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-5mm, 0-200mils
    • Accuracy: ±1-3% or ±20μm, ±1-3% or ±1.0mil
    • Minimum Headroom: 185mm (7.28")
    • Minimum Sample Diameter: 14mm (0.55”)
    • Part Number : T456CN2P
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-13mm, 0-500mils
    • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 102mm (4.02”)
    • Minimum Sample Diameter: 14mm (0.55”)
    • Part Number : T456CF3S
  • Elcometer 456 Coating Thickness Gauge PINIP™ Integral Probe - Scale 3
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-13mm, 0-500mils
    • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
    • Minimum Headroom: 184mm (7.24”)
    • Minimum Sample Diameter: 14mm (0.55”)
    • Part Number : T456CF3P
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 3
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-13mm, 0-500mils
    • Accuracy: ±1-3% or ±50μm, ±1-3% or ±2.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 170mm (6.69”)
    • Minimum Sample Diameter: 35mm (1.38”)
    • Part Number : T456CN3S
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
    • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 150mm (5.90”)
    • Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
    • Part Number : T456CF6S
  • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
    • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 190mm (7.48”)
    • Minimum Sample Diameter: 51 x 51mm2 (2.17 x 2.17 inch2)
    • Part Number : T456CF6ARM
  • Elcometer 456 Coating Thickness Gauge Straight Probe - Scale 6
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
    • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 160mm (6.30”)
    • Minimum Sample Diameter: 58mm (2.29”)
    • Part Number : T456CN6S
  • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 6
    • Substrate Probe: Non-Ferrous (N) Probes
    • Range: 0-13mm, 0-500mils, F: 0-25mm, N: 0-30mm, F: 0-980mils, N: 0-1,200mils
    • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 200mm (7.87")
    • Minimum Sample Diameter: 58mm (2.29”)
    • Part Number : T456CN6ARM
  • Elcometer 456 Coating Thickness Gauge Straight Probe armoured cable - Scale 7
    • Substrate Probe: Ferrous (F) Probes
    • Range: 0-31mm, 0-1220mils
    • Accuracy: ±1-3% or ±100μm, ±1-3% or ±4.0mils
    • Probe Length: 45mm (1.77”)
    • Minimum Headroom: 200mm (7.87")
    • Minimum Sample Diameter: 55 x 55mm2 (2.17 x 2.17 inch2)
    • Part Number : T456CF7ARM
   
Accessories
Elcometer 456 Coating Thickness Gauge Probe Range
  • Part Number: T9997766-
  • Part Number: T99913225
  • Part Number: T9997381-
  • Part Number: T99913133
  • Part Number: T456C23956
  • Part Number: T456C29050