Elcometer 130 SSP Soluble Salt Profiler

  • Protective Coatings
Elcometer-130-SSP-Only-intro
Elcometer-130-SSP-Closed-intro_1

The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level and density of soluble salts - over 4 times faster than other Bresle equivalent methods.

  • Summary
    • Summary

    • Elcometer 130 SSP Bresle Equiivalent Screen

      Four Bresle equivalent readings in 2½ minutes

      Each filter paper is the size of four Bresle patches - the Elcometer 130 Soluble Salt Profiler not only displays the individual reading but also provides four Bresle equivalent readings in just over two minutes.

      Tested under laboratory conditions in accordance with ISO 8502-9, the Elcometer 130 SSP provides equivalent measurements to the Bresle Patch Method. Click here to see the full report.

      Elcometer 130 SSP Soluble Salt Profiler Density Map Screen

      Detailed Analysis

      In addition to soluble salt levels (cleanliness) or conductivity, the Elcometer 130 SSP Soluble Salt Tester carries out a detailed analysis of the test area - providing an accurate salt density profile map, pinpointing areas of high contamination outside user defined limits.

      3D-salt-density-profile

      Generate instant reports with ElcoMaster® Data Management Software

      The Elcometer 130 SSP Soluble Salt Meter wirelessly transmits readings, statistics and batches via Bluetooth® or via USB straight into an inspection application or into ElcoMaster® software, Elcometer ’s Mobile App, for instant report generation at your desk, or using your mobile in the field.

      The new Elcometer 130 Soluble Salt Meter allows you to complete a Bresle equivalent test in just over two minutes.

      The multi-point conductivity sensors enable the Elcometer 130 SSP Soluble Salt Tester to accurately display salt concentration, showing exactly where the contamination lies and generating full colour salt density maps in 2D or 3D.

      Key features of the Elcometer 130 Soluble Salt Profiler include:

      • Range of measurement modes:
        • Cleanliness: two measurement options are available when measuring soluble salts – Bresle Method Equivalency or Elcometer 130 Equivalency mode
        • Conductivity: ideal for measuring ionic contaminants, sometimes referred to as total dissolved solids –TDS, within a solution
      • Multi-point conductivity sensor allows the trend in conductivity to be displayed as a density map
      • Automatic temperature compensation ensures accurate results
      • Large colour LCD screen displays readings in µg/cm², ppm, µS/cm, mS/cm, % salinity or mg/m²
      • Stores up to 3,500 sets of readings in 1,000 alpha numeric batches
      • Non-oxidising gold plated contacts ensure lifetime performance
      • Transfer data via USB or Bluetooth® to ElcoMaster® for instant report generation

      ElcoMaster® Data Management Software

      Inspectors can spend up to 30% of their working week producing reports. ElcoMaster® Software saves time and money by producing professional bespoke reports - even when out on site.

  • Key Features
    • Key Features

      Elcometer 130 SSP Soluble Salt Profiler

      Elcometer 130 SSP

      Accurate in all environments

      The Elcometer 130 SSP Soluble Salt Meter has automatic temperature compensation ensuring accuracy in all climatic conditions. Impure water can be offset for accurate and repeatable readings.

      Elcometer 130 SSP

      Designed to last

      Robust, durable & water resistant, the Elcometer 130 SSP Soluble Salt Profiler is available with a 2 year manufacturer’s warranty; giving you peace of mind.

      Elcometer 130 SSP 3D Density Map Screen

      Calibration verification - peace of mind

      A Calibration Verification Tile is available for verifying the accuracy of the gauge whilst out in the field and the verification date is recorded for use in reports.

      Display Modes

      Large-Single-Reading

      Large Single Reading

      The reading value is displayed for the whole sample.

      Elcometer-130-Display-2

      Four Bresle Patch Equivalent Readings

      The measurement area is split into four Bresle Patch size quadrants and four Bresle Patch or Elcometer 130 equivalent readings are displayed simultaneously.

      Elcometer-130-Display-3

      Pass/Fail to User Defined Limits

      Provides a visual indication of salt contamination. Areas, where soluble salts levels are above the limit set, are shaded red, areas below the limit are white. The measurement bar to the left of the pass/fail map displays the limit (above the bar) and the percentage test area above the defined limit (below the bar). The bar is also a visual indication of the pass/fail percentage. The highest (Hi), lowest (Lo) and average (X) reading for the current measurement are displayed to the right.

      Elcometer-130-Display-4

      2D Salt Density Map with High/Low Readings

      Levels of soluble salts are illustrated using a green and red contour system; green for very low salt concentration or uncontaminated areas; yellow for areas with mid salt concentration; and red for areas with levels of salt contamination exceeding the defined map scale range.

      Elcometer-130-Display-5

      3D Salt Density Profile & Peak Salt Concentration (Hi)

      Provides a visual indication of the density of salt contamination over the test area.

      How to use the Elcometer 130 Soluble Salt Profiler

      How to use the Elcometer 130 SSP - Step 1Wearing clean disposable gloves (supplied), fill a syringe with precisely 1.6ml of pure distilled water.

      How to use the Elcometer 130 SSP - Step 2Using tweezers, remove a filter paper from the pack and place it on the cleaned, non-labelled side of the magnetic disc supplied.

      How to use the Elcometer 130 SSP - Step 3Disperse the water from the syringe, evenly across the whole of the filter paper and remove any bubbles from under the paper.

      How to use the Elcomter 130 SSP - Step 4Place the magnetic disc, wetted face down, onto the area under test, pressing firmly into any contours or irregularities and start the 2 minute timer on the gauge.

      How to use the Elcomter 130 SSP - Step 5After two minutes, carefully remove the filter paper and magnetic disc from the test surface and place them onto the measurement electrodes.

      How to use the Elcomter 130 SSP - Step 6As each filter paper remains on the surface for two minutes, multiple tests can be undertaken at the same time, reducing inspection times further.

      How to use the Elcometer 130 SSP - Step 7Close the lid, ensuring that the magnetic catch is fully engaged, the gauge will begin measuring.

      How to use the Elcometer 130 SSP - Step 8The reading will be displayed on the screen in the chosen display mode.

      How to use the Elcometer 130 SSP - Step 9If required for further analysis, place the filter paper in a resealable bag (supplied).

      Elcometer 130 SSP Soluble Salt Meter: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation).

      “Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.

      iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.

  • Product Features
    • Product Features
      Elcometer 130 SSP Soluble Salt Profiler
        Model SSP
      Repeatable & reproducible measurements
      Easy to use menu structure; in 30+ languages
      Tough, impact, waterproof & dust resistant; equivalent to IP64
      Bright colour screen; with permanent backlight
      Scratch and solvent resistant display; 2.4" (6cm) TFT
      2 year gauge warranty1
      USB power supply; via PC
      Calibration certificate
      Calibration Verification Mode (with optional certified calibration tile)
      Ambient light sensor; with adjustable auto brightness
      Emergency Light Mode
      Magnetic & tripod mounting points
      Data output, USB to PC & Bluetooth® to PC, Android™ & iOS2devices
      On screen statistics  
      Number of readings (n); Mean/Average, (x); Standard deviation (σ); Highest reading/Peak salt concentration (Hi;) Lowest reading (Lo); Coefficient of variation (CV%); Number of readings above high limit
      Gauge memory  
      Number of individual reading sets; including salt density, pass/fail map & distribution graph
      3,500
      Number of batches
      1,000
      Measurement units & range  
      Surface Cleanliness - Elcometer 130 Mode
      0-50µg/cm², 0-500mg/m²
      Surface Cleanliness - Bresle Equivalent Method Mode
      0-15µg/cm², 0-150mg/m²
      Conductivity
      0-6000μS/cm, 0-6mS/cm
      0-3000ppm, 0-0.3% Salinity
      Resolution  
      Surface Cleanliness
      0.1μg/cm², 1mg/m²
      Conductivity
      1μS/cm, 0.001mS/cm
      1ppm, 0.0001% Salinity
      Gauge Accuracy
      ±1% of reading
      Measurement Mode  
      Surface Cleanliness
      Conductivity
      Calibration Offset Mode
      Automatic temperature compensation
      ElcoMaster® software & USB cable
      Individual reading and profile map stored with time and date
      Plastic transit case
      Alpha-numeric batch names; user definable on the gauge
      Fixed Batch Size Mode; with batch linking
      Delete last reading
      Limits; (gauge & batch specific)
      Review, copy, clear & delete batches & calibration settings
      Trend graph; last 20 readings
      Batch review graph
      Analogue bar graph

      1 The Elcometer 130 SSP is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase

      2 Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.

  • Technical Information
    • Technical Specification
      Elcometer 130 SSP Soluble Salt Profiler
      Part Number Description Certificate
      E130-SP Elcometer 130 Soluble Salt Profiler1
      E130-SPC Elcometer 130 Certified Soluble Salt Profiler1
      Calibration Certificate supplied as standard
      Operating Range 5°C - 40°C (41°F - 104°F)
      Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used)
      Battery Life Alkaline: Approximately 30 hours
      Lithium: Approximately 45 hours
      Sample Time Sample Time
      Sampling Size 110mm (4.3”) circle
      Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9")
      Weight 780g (1.72lb)
      Packing List Elcometer 130 Soluble Salt Profiler, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3.0ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable, ElcoMaster® software
      1 Applicable Patents: GB 2527766
      Calibration Certificate supplied as standard.
  • Standards
    • Standards
      Elcometer 130 SSP Soluble Salt Profiler

      NSI 009-32, SSPC Guide 15, Bresle Equivalent ISO 8502-9 Test Method

  • Downloads
    • Downloads
        • Elcometer 130 SSP Soluble Salt Profiler Multi-Lingual Instruction Manual

        • Elcometer 130 SSP Soluble Salt Profiler Datasheet

        • Elcometer 130 SSP Soluble Salt Profile CE Declaration of Conformity

        • Elcometer 130 Soluble Salt Profiler UKCA Declaration of Conformity

  • Part Numbers
    • Part Numbers
      Elcometer 130 SSP Soluble Salt Profiler
      • Elcometer 130 Soluble Salt Profiler
        • Part Number : E130-SP
      • Elcometer 130 Certified Soluble Salt Profiler
        • Part Number : E130-SPC
  • Accessories
    • Accessories
      Elcometer 130 SSP Soluble Salt Profiler
      • Part Number: T13027115
      • Part Number: T13025964
      • Part Number: T13024091
      • Part Number: T13024093
      • Part Number: T99911344
      • Part Number: T13027596
      • Part Number: T13024094
      • Part Number: T13024092
      • Part Number: T13024098
      • Part Number: T13024087
      • Part Number: T99920130

Elcometer 130 SSP Soluble Salt Profiler

  • Protective Coatings
Elcometer-130-SSP-Only-intro
Elcometer-130-SSP-Closed-intro_1

The Elcometer 130 Soluble Salt Profiler provides fast and accurate measurement of the level and density of soluble salts - over 4 times faster than other Bresle equivalent methods.

Elcometer 130 SSP Bresle Equiivalent Screen

Four Bresle equivalent readings in 2½ minutes

Each filter paper is the size of four Bresle patches - the Elcometer 130 Soluble Salt Profiler not only displays the individual reading but also provides four Bresle equivalent readings in just over two minutes.

Tested under laboratory conditions in accordance with ISO 8502-9, the Elcometer 130 SSP provides equivalent measurements to the Bresle Patch Method. Click here to see the full report.

Elcometer 130 SSP Soluble Salt Profiler Density Map Screen

Detailed Analysis

In addition to soluble salt levels (cleanliness) or conductivity, the Elcometer 130 SSP Soluble Salt Tester carries out a detailed analysis of the test area - providing an accurate salt density profile map, pinpointing areas of high contamination outside user defined limits.

3D-salt-density-profile

Generate instant reports with ElcoMaster® Data Management Software

The Elcometer 130 SSP Soluble Salt Meter wirelessly transmits readings, statistics and batches via Bluetooth® or via USB straight into an inspection application or into ElcoMaster® software, Elcometer ’s Mobile App, for instant report generation at your desk, or using your mobile in the field.

Summary

Elcometer 130 SSP Soluble Salt Profiler

The new Elcometer 130 Soluble Salt Meter allows you to complete a Bresle equivalent test in just over two minutes.

The multi-point conductivity sensors enable the Elcometer 130 SSP Soluble Salt Tester to accurately display salt concentration, showing exactly where the contamination lies and generating full colour salt density maps in 2D or 3D.

Key features of the Elcometer 130 Soluble Salt Profiler include:

  • Range of measurement modes:
    • Cleanliness: two measurement options are available when measuring soluble salts – Bresle Method Equivalency or Elcometer 130 Equivalency mode
    • Conductivity: ideal for measuring ionic contaminants, sometimes referred to as total dissolved solids –TDS, within a solution
  • Multi-point conductivity sensor allows the trend in conductivity to be displayed as a density map
  • Automatic temperature compensation ensures accurate results
  • Large colour LCD screen displays readings in µg/cm², ppm, µS/cm, mS/cm, % salinity or mg/m²
  • Stores up to 3,500 sets of readings in 1,000 alpha numeric batches
  • Non-oxidising gold plated contacts ensure lifetime performance
  • Transfer data via USB or Bluetooth® to ElcoMaster® for instant report generation

ElcoMaster® Data Management Software

Inspectors can spend up to 30% of their working week producing reports. ElcoMaster® Software saves time and money by producing professional bespoke reports - even when out on site.

Downloads
    • Elcometer 130 SSP Soluble Salt Profiler Multi-Lingual Instruction Manual

    • Elcometer 130 SSP Soluble Salt Profiler Datasheet

    • Elcometer 130 SSP Soluble Salt Profile CE Declaration of Conformity

    • Elcometer 130 Soluble Salt Profiler UKCA Declaration of Conformity

Key Features

Elcometer 130 SSP Soluble Salt Profiler

Elcometer 130 SSP

Accurate in all environments

The Elcometer 130 SSP Soluble Salt Meter has automatic temperature compensation ensuring accuracy in all climatic conditions. Impure water can be offset for accurate and repeatable readings.

Elcometer 130 SSP

Designed to last

Robust, durable & water resistant, the Elcometer 130 SSP Soluble Salt Profiler is available with a 2 year manufacturer’s warranty; giving you peace of mind.

Elcometer 130 SSP 3D Density Map Screen

Calibration verification - peace of mind

A Calibration Verification Tile is available for verifying the accuracy of the gauge whilst out in the field and the verification date is recorded for use in reports.

Display Modes

Large-Single-Reading

Large Single Reading

The reading value is displayed for the whole sample.

Elcometer-130-Display-2

Four Bresle Patch Equivalent Readings

The measurement area is split into four Bresle Patch size quadrants and four Bresle Patch or Elcometer 130 equivalent readings are displayed simultaneously.

Elcometer-130-Display-3

Pass/Fail to User Defined Limits

Provides a visual indication of salt contamination. Areas, where soluble salts levels are above the limit set, are shaded red, areas below the limit are white. The measurement bar to the left of the pass/fail map displays the limit (above the bar) and the percentage test area above the defined limit (below the bar). The bar is also a visual indication of the pass/fail percentage. The highest (Hi), lowest (Lo) and average (X) reading for the current measurement are displayed to the right.

Elcometer-130-Display-4

2D Salt Density Map with High/Low Readings

Levels of soluble salts are illustrated using a green and red contour system; green for very low salt concentration or uncontaminated areas; yellow for areas with mid salt concentration; and red for areas with levels of salt contamination exceeding the defined map scale range.

Elcometer-130-Display-5

3D Salt Density Profile & Peak Salt Concentration (Hi)

Provides a visual indication of the density of salt contamination over the test area.

How to use the Elcometer 130 Soluble Salt Profiler

How to use the Elcometer 130 SSP - Step 1Wearing clean disposable gloves (supplied), fill a syringe with precisely 1.6ml of pure distilled water.

How to use the Elcometer 130 SSP - Step 2Using tweezers, remove a filter paper from the pack and place it on the cleaned, non-labelled side of the magnetic disc supplied.

How to use the Elcometer 130 SSP - Step 3Disperse the water from the syringe, evenly across the whole of the filter paper and remove any bubbles from under the paper.

How to use the Elcomter 130 SSP - Step 4Place the magnetic disc, wetted face down, onto the area under test, pressing firmly into any contours or irregularities and start the 2 minute timer on the gauge.

How to use the Elcomter 130 SSP - Step 5After two minutes, carefully remove the filter paper and magnetic disc from the test surface and place them onto the measurement electrodes.

How to use the Elcomter 130 SSP - Step 6As each filter paper remains on the surface for two minutes, multiple tests can be undertaken at the same time, reducing inspection times further.

How to use the Elcometer 130 SSP - Step 7Close the lid, ensuring that the magnetic catch is fully engaged, the gauge will begin measuring.

How to use the Elcometer 130 SSP - Step 8The reading will be displayed on the screen in the chosen display mode.

How to use the Elcometer 130 SSP - Step 9If required for further analysis, place the filter paper in a resealable bag (supplied).

Elcometer 130 SSP Soluble Salt Meter: Made for iPhone 6 Plus, iPhone 6, iPhone 5s, iPhone 5c, iPhone 5, iPhone 4s, iPad Air 2, iPad mini 3, iPad Air, iPad mini 2, iPad (3rd and 4th generation), iPad mini, iPad 2, and iPod touch (5th generation).

“Made for iPod,” “Made for iPhone,” and “Made for iPad” mean that an electronic accessory has been designed to connect specifically to iPod, iPhone, or iPad, respectively, and has been certified by the developer to meet Apple performance standards. Apple is not responsible for the operation of this device or its compliance with safety and regulatory standards. Please note that the use of this accessory with iPod, iPhone, or iPad may affect wireless performance.

iPad, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a trademark of Apple Inc., registered in the U.S. and other countries. Suitable for mobile devices running Android™ software version 2.1 and upwards. Android™ and Google Play are trademarks of Google Inc.

Product Features
Elcometer 130 SSP Soluble Salt Profiler
  Model SSP
Repeatable & reproducible measurements
Easy to use menu structure; in 30+ languages
Tough, impact, waterproof & dust resistant; equivalent to IP64
Bright colour screen; with permanent backlight
Scratch and solvent resistant display; 2.4" (6cm) TFT
2 year gauge warranty1
USB power supply; via PC
Calibration certificate
Calibration Verification Mode (with optional certified calibration tile)
Ambient light sensor; with adjustable auto brightness
Emergency Light Mode
Magnetic & tripod mounting points
Data output, USB to PC & Bluetooth® to PC, Android™ & iOS2devices
On screen statistics  
Number of readings (n); Mean/Average, (x); Standard deviation (σ); Highest reading/Peak salt concentration (Hi;) Lowest reading (Lo); Coefficient of variation (CV%); Number of readings above high limit
Gauge memory  
Number of individual reading sets; including salt density, pass/fail map & distribution graph
3,500
Number of batches
1,000
Measurement units & range  
Surface Cleanliness - Elcometer 130 Mode
0-50µg/cm², 0-500mg/m²
Surface Cleanliness - Bresle Equivalent Method Mode
0-15µg/cm², 0-150mg/m²
Conductivity
0-6000μS/cm, 0-6mS/cm
0-3000ppm, 0-0.3% Salinity
Resolution  
Surface Cleanliness
0.1μg/cm², 1mg/m²
Conductivity
1μS/cm, 0.001mS/cm
1ppm, 0.0001% Salinity
Gauge Accuracy
±1% of reading
Measurement Mode  
Surface Cleanliness
Conductivity
Calibration Offset Mode
Automatic temperature compensation
ElcoMaster® software & USB cable
Individual reading and profile map stored with time and date
Plastic transit case
Alpha-numeric batch names; user definable on the gauge
Fixed Batch Size Mode; with batch linking
Delete last reading
Limits; (gauge & batch specific)
Review, copy, clear & delete batches & calibration settings
Trend graph; last 20 readings
Batch review graph
Analogue bar graph

1 The Elcometer 130 SSP is supplied with a 1 year warranty against manufacturing defects. The warranty can be extended free of charge to 2 years within 60 days of purchase

2 Visit www.elcometer.com/sdk to find out how to integrate Elcometer’s MFi certified products to your App.

Technical Specification
Elcometer 130 SSP Soluble Salt Profiler
Part Number Description Certificate
E130-SP Elcometer 130 Soluble Salt Profiler1
E130-SPC Elcometer 130 Certified Soluble Salt Profiler1
Calibration Certificate supplied as standard
Operating Range 5°C - 40°C (41°F - 104°F)
Power Supply 4 x AA batteries or via USB (rechargeable batteries can also be used)
Battery Life Alkaline: Approximately 30 hours
Lithium: Approximately 45 hours
Sample Time Sample Time
Sampling Size 110mm (4.3”) circle
Dimensions 250 x 145 x 50mm (9.8 x 5.7 x 1.9")
Weight 780g (1.72lb)
Packing List Elcometer 130 Soluble Salt Profiler, 3 x magnetic discs, 100 x high purity test papers, 250ml (8.5fl oz) pure distilled water, 20 x PVC storage bags, disposable gloves, sensor wipes, 3 x 3.0ml (0.1fl oz) syringes, 2 x plastic tweezers, 4 x AA batteries, shoulder strap, plastic transit case, test certificate and operating instructions, USB cable, ElcoMaster® software
1 Applicable Patents: GB 2527766
Calibration Certificate supplied as standard.
Standards
Elcometer 130 SSP Soluble Salt Profiler

NSI 009-32, SSPC Guide 15, Bresle Equivalent ISO 8502-9 Test Method

Part Numbers
Elcometer 130 SSP Soluble Salt Profiler
  • Elcometer 130 Soluble Salt Profiler
    • Part Number : E130-SP
  • Elcometer 130 Certified Soluble Salt Profiler
    • Part Number : E130-SPC
   
Accessories
Elcometer 130 SSP Soluble Salt Profiler
  • Part Number: T13027115
  • Part Number: T13025964
  • Part Number: T13024091
  • Part Number: T13024093
  • Part Number: T99911344
  • Part Number: T13027596
  • Part Number: T13024094
  • Part Number: T13024092
  • Part Number: T13024098
  • Part Number: T13024087
  • Part Number: T99920130